1.
On/Off LED - A green LED is on when:
The power cable is connected to the mains power supply.
The trunk cable is connected to the system.
The central control unit is started.
2.
DCN cable - Connects the extension power supply to the trunk of the DCN system.
3.
DCN socket (trunk) - Makes a loop-through in the trunk of the DCN system.
4.
DCN sockets (tap-off) - Make tap-offs in the DCN system. The socket regenerates the
DCN system signal.
5.
Power inlet - Mains power supply connection.
6.
Fuse holder - Prevents damage to the internal power supply unit of the extension power
supply.
The following sections give more information about the mentioned subject:
–
Installation: DCN-EPS Extension Power Supply, page 109.
–
Connection: DCN-EPS Extension Power Supply, page 144.
–
Configuration: DCN-EPS Extension Power Supply, page 226.
–
Technical Data: DCN-EPS Extension Power Supply, page 286.
LBB4114/00 Trunk Splitter
Use the LBB4114/00 Trunk Splitter to divide the DCN trunk.
1
2
4
3
Figure 3.57: Top and side views
1.
DCN socket (tap-off 1) - Makes a tap-off in the DCN system. The socket regenerates the
DCN signal.
2.
DCN socket (tap-off 2) - Makes a tap-off in the DCN system. The socket regenerates the
DCN system signal.
3.
DCN cable - Connects the trunk splitter in the trunk of the DCN system.
4.
DCN socket (trunk) - Makes a loop-through in the DCN with the trunk splitter. The socket
does not regenerate the DCN system signal.
The following sections give more information about the mentioned subject:
–
Installation: LBB4114/00 Trunk Splitter, page 110.
–
Connection: LBB4114/00 Trunk Splitter, page 146.
–
Technical Data: LBB4114/00 Trunk Splitter, page 286.