Add the NSFs of the flush-mounted devices to get the total NSF.
–
Use the total NSF to get the length (x) of the recess from the table. The length includes
the DCN-FCOUP couple pieces.
Notice!
Install DCN-FEC End Caps on the couple pieces at the two ends of the recess.
Total NSF
x (mm)
1
71.5
2
121.5
3
171.5
4
221.5
5
271.5
6
321.5
7
371.5
8
421.5
9
471.5
10
521.5
11
571.5
12
621.5
Table 5.2: Lengths, block-mounting method
Number-size factor
The length of a recess depends on:
–
The number of flush-mounted devices that are installed in the recess.
–
The size of the flush-mounted devices that are installed in the recess.
To calculate the length of a recess, you must use the number-size factor (NSF, refer the table)
of the flush-mounted devices.
Flush-mounted device
NSF
DCN-FCS
2
DCN-FLSP
2
DCN-FMIC
1
DCN-FMICB
1
DCN-FPRIOB
1
DCN-FV
2
DCN-FVCRD
2
106 en | Installation
Conference System
2013.11 | V2.0 | DCN-NG_OM_V4.x
Operation Manual
Bosch Security Systems B.V.