24
26
ALARM ENABLE
#
PINcode
Bodet GSM 0.48
Alarm: ON
GSM: 50%
Temp: 19.3C
230V
IN1: LO
IN2: LO
IN3: LO
32V
IN4: LO
IN5: LO
OUT1: OFF
OUT2: OFF
OUT3: OFF
BLOCK: OFF
Client product name - Firmware version
Alarm status (ON/OFF)
Level of GSM reception
Temperature of the device
List of 230V inputs (IN1/2/3)
Not used
Not used
Not used
List of 32V inputs (IN4/5)
Alarm input status - Selectable alert*.
Alarm input status - Selectable alert*.
Control status - Alert A (ON/OFF)
Control status - Alert B (ON/OFF)
Control status - Alert C (ON/OFF)
“BLOCK" mode status (ON/OFF)
ON: enabled, OFF: disabled
* LO: no alarm HI: active alarm
27
SET IDLEALARM 1
#
PINcode
BodetGSM 0.48
-----------
Time: 15:35
Date: 19.07.21 Mo
Relays time: 5s
Alarm every 1 min
Client product name - Firmware version
-----------
Time programmed in the device
Date programmed in the device
Time between 2 status changes of a relay
Time between 2 alarm messages
28
SET TEL +33xxxxxxxxx G1
MARTIN
#
PINcode
BodetGSM 0.48
Tel01 Name: MARTIN
Tel01 Ne: +33xxxxxxxxx
Tel01 Group: G1
Client product name - Firmware version
Location number and name of the registered contact
Location number and telephone number registered
Location number and group assigned to the contact
29
TEST TEL
#
G1
#
PINcode
BodetGSM 0.48
Grp: G1
Member
01 MARTIN
Client product name - Firmware version
Group identification
List of contacts registered in the group
30
TEST G1
#
PINcode
BodetGSM 0.48
G1_ALARMSMS: ON
G1_INCALL1: NO
G1_INCALL2: NO
G1_INCALL3: NO
G1_NEWS: ON
G1_SMSFORWARD: NO
Client product name - Firmware version
Function enabled
Function disabled
Function disabled
Function disabled
Function enabled
Function disabled
31
STATUS
#
PINcode
BodetGSM 0.48
Alarm: ON
GSM: 50%
Temp: 19.3C
230V
IN1: LO
IN2: LO
IN3: LO
32V
IN4: LO
IN5: LO
OUT1: OFF
OUT2: OFF
OUT3: OFF
BLOCK: OFF
Client product name - Firmware version
Alarm status (ON/OFF)
Level of GSM reception
Temperature of the device
List of 230V inputs (IN1/2/3)
Not used
Not used
Not used
List of 32V inputs (IN4/5)
Alarm input status - Selectable alert*.
Alarm input status - Selectable alert*.
Control status - Alert A (ON/OFF)
Control status - Alert B (ON/OFF)
Control status - Alert C (ON/OFF)
“BLOCK" mode status (ON/OFF)
ON: enabled, OFF: disabled
* LO: no alarm HI: active alarm
32
SET PIN 1234
#
PINcode
BodetGSM 0.48
-----------
The PIN code has been
changed to 1234
Please use now #1234
Client product name - Firmware version
-----------
Confirmation message indicating the change of PIN
code for the device and the SIM card.
EN