8
Clock type
Dip 1
Dip 2
CHRONOLED
1
0
Clock type
Dip 1
Dip 2
Dip 3
Dip 4
Dip 5
MASTER
HMT LED
0
0
/
/
/
HMS LED
0
1
/
/
/
SLAVE
Slave 1
1
0
0
0
1
Slave 2
1
0
0
1
0
Slave 3
1
0
0
1
1
Slave 4
1
0
1
0
0
Slave 5
1
0
1
0
1
Slave 6
1
0
1
1
0
Slave 7
1
0
1
1
1
RS 485 connector for slave sync.
III.4 Chronoleds in series
Up to 8 Chronoleds can be connected in series (1 master and up to 7 slaves).
- Set one Chronoled as master via the dips, then all the other Chronoled as
slave (each slave Chronoled must have a unique number). See table above.
- Connect the RS485 synchronization cable to the RS485 connector of each
Chronoled. See the above illustration.
III.5 Pairing an HF remote control
Using the HF remote control to operate the Chronoled requires pairing. This operation is
performed in the factory.
Pairing is accomplished during a limited time of 30sec after powering up the
Chonoled by holding down the [T] key for 1 sec, 88 is then displayed.
Unpairing a remote control is performed identically to pairing.
Note: everytime a Chronoled is powered up, a remote control which is already
paired is inactive for 30 seconds
.