15
IV.5 PROG menu: setting brightness, relay, time base
1. Enter the PROG menu (see page 10).
2. The brightness value flashes (A1 to A3 then M1 to 9).
Modify with the [R] key. The values A1 to A3 are automatic
brightness adjustments (brightness varies according to
ambient light). The values M1 to M9 are manual brightness
settings (brightness is fixed regardless of ambient light).
Brightness of the display is modified in real time, and in
a multi-panel installation, each panel manages its own
brightness.
.
3. Press the [S] key to validate brightness to set the time base.
4. The selected timing mode (*) flashes (ru or St). Modify with
the [R] key.
The ‘ru’ mode (run) allows to restart automatically and
permanently the same count/countdown (at the end of a count/
countdown, the Chronoled returns automatically to its initial
value and restarts the same count/countdown).
The ‘St’ mode (stop) stops at the end of count/countdown.
5. Press the [S] key to validate the parameter and go to setting
the time of the count/countdown end relay (*).
6. The time of activation of the automatic relay (horn) at the
end of count/countdown (*) flashes (from 0 to 9 or – to
deactivate the relay). Modify with the [R] key.
7. Press the [S] key to validate.
9. Press the [S] key to validate the timing mode. The display
returns to the normal mode.
(*) These menus exist only when the timing mode is activated.