-8-
Revision 1/F3586
Water Connection
• A cold water supply should be fitted to the
water inlet (¾” BSP hose connection)
which is located on the rear of the right
hand side of the unit.
•
Alternately, a connection elbow and
sealing washer is supplied with this unit
for direct connection of a ½” ID hose, and
is recommended for easy installation and
service.
• Connect water supply - Max inlet pressure
80psi / 550kPa.
• Turn on water supply to check for leaks.
Before Connection to Power Supply
• Remove all packing.
• Check equipment and parts for damage.
Report any damage immediately to the
carrier and distributor.
• Remove protective plastic coating from
the side panels.
• Check that the following parts have been
supplied with your oven:
4 x Foot assembly
4 x Oven racks
1 x Water inlet elbow (c/w washer)
• Report any deficiencies to the distributor
who supplied the oven.
• Fit the feet to the oven.
• Check that the available power supply is
correct to that shown on the rating plate
located on the right -hand side panel.
208-220 V AC, 50 Hz, 28.8 A, 6.0 kW
208 V AC, 60 Hz, 28.8 A, 6.0 kW
230-240 V AC, 50 Hz, 27.8 A, 6.7 kW
220-240 V AC, 60 Hz, 27.8 A, 6.7 kW
Location
• To ensure correct ventilation for the motor
and controls the following minimum
installation clearances are to be adhered
to:
Rear 40mm / 1½”
Left-hand side 40mm / 1½”
Right-hand side* 40mm / 1½”
Top 390mm / 16”
* Fixed installations require at least
500mm (20”) clearance at the right
hand side for service accessibility.
• Position the oven in its working position.
2. INSTALLATION
IMPORTANT:
THE OVEN VENT
LOCATED ON THE CABINET TOP
MUST NEVER BE OBSTRUCTED.
WARNING: THIS APPLIANCE MUST BE GROUNDED.
floor mounting or provided with stands are
adjustable and will require adjusting in
levelling the unit.
• The unit should be positioned such that
the operating panel and oven shelves are
easily reachable for loading and
unloading.
Electrical Connection
• Remove right hand side panel to allow
access to the terminal block and strain
relief cable clamp.
• The cable can be fitted through the small
grommet and held by the cable clamp.
•
Connect cable to the terminals as
marked.
• Refit cover panel.
IMPORTANT:
MAXIMUM INLET WATER
PRESSURE IS 550 kPa / 80 psi.
WARNING: ALL INSTALLATION AND SERVICE REPAIR WORK MUST BE CARRIED
OUT BY QUALIFIED PERSONS ONLY.
Figure 2.1
L1
L2
Ground
Phase
Neutral
RED
BROWN
BLACK
GREEN/YELLOW
GREEN
WARNING:
THIS APPLIANCE MUST
BE GROUNDED / EARTHED
BLACK
BLUE
WHITE
• Use a spirit level to ensure oven is level
from side to side and front to back. (If this
is not carried out, uneven cooking could
occur). The feet/legs used with bench/