-29-
Revision 1/F3586
6.3.12 WATER SOLENOID
5) Withdraw old thermostat phial through
side of oven. Note position in phial
bracket.
6) Insert new thermostat.
7) Re-assemble in reverse order.
NOTE:
Ensure that the thermostat phials are
located in their correct positions. The
main thermostat probe must be on the
side closest to the door. The hold
thermostat must be on the side closest to
the fan and elements.
1) Ensure water supply is turned off.
2) To access the solenoid, remove the right
hand service panel (refer 6.2.2)
3) Disconnect all water connections from the
water solenoid.
4)
Remove water solenoid from oven by
removing two screws securing the water
solenoid to its mounting bracket.
Figure 6.3.14
6.3.11 HEATING CONTACTOR
1)
Remove the right hand service panel
(refer 6.2.2).
2) Unclip contactor from the gear plate.
Figure 6.3.13
3) Clip new contactor onto gear plate.
4) Transfer wires from old contactor to new
contactor, ensuring all wires are in their
correct positions.
Contactor
Control thermostat
phial
Hold thermostat
phial
Towards
the
door
Figure 6.3.11
Two screws
6.3.10 HOLD THERMOSTAT
1) Open control panel (refer 6.2.1) and undo
two screws securing hold thermostat
bracket.
2) Remove the two screws securing the hold
thermostat to the bracket, and then fit the
new thermostat in its place.
3) Transfer wires to new thermostat.
3) Open oven door, remove racks and fan
baffle rack. Loosen the thermostat phial
bracket (refer figure 6.3.10).
Figure 6.3.12
4) Withdraw the old hold thermostat phial
through the side of the oven. Note the
position of the phial in the bracket.
5) Insert new thermostat phial.
6) Re-assemble in reverse order.
NOTE:
Ensure that the thermostat phials are
located in their correct positions. The
main thermostat probe must be on the
side closest to the door. The hold
Water
solenoid