-16-
Revision 1/F3586
FAULT
POSSIBLE CAUSE
REMEDY
NO WATER INJECTION /
STEAM
Water not turned on.
Oven water nozzle blocked.
Fault with water valve.
(Refer fault diagnosis 6.1.5)
Steam switch faulty.
Turn water on at water supply.
Remove, clean or replace.
(Refer service section 6.3.14)
Service or replace as required.
(Refer service section 6.3.12,
6.3.13)
Replace.
(Refer service section 6.3.4)
CONTINUOUS WATER OUT
OF OVEN WATER NOZZLE
With oven on only—Electrical
fault.
(Refer fault diagnosis 6.1.6)
With oven on or off - water
valve faulty or requires
cleaning.
Correct electrical fault.
Service or replace as required.
(Refer service section 6.3.12,
6.3.13)
60 MINUTE TIMER WILL NOT
TIME DOWN
60 MINUTE TIMER
INACCURATE BELOW 20
MINUTES
60 MINUTE TIMER NO TIME
UP BUZZER
60 MINUTE TIMER NO TIME
UP INDICATOR
Timer faulty.
Timer not set correctly.
Zero (time up) position not set
correctly.
Buzzer faulty.
(Refer fault diagnosis 6.1.7)
Timer not switching on buzzer.
(Refer fault diagnosis 6.1.7)
Indicator faulty.
(Refer fault diagnosis 6.1.8)
Replace.
(Refer service section 6.3.7)
For timer settings below 20
minutes, always rotate past 20
minutes, then back to desired
time.
(Refer service section 6.4.6)
Replace.
(Refer service section 6.3.5)
Replace.
(Refer service section 6.3.7)
Replace.
(Refer service section 6.3.3)
NO HEAT
No power to thermostat.
(Refer fault diagnosis 6.1.9)
Thermostat faulty.
(Refer fault diagnosis 6.1.9)
Heating contactor faulty.
(Refer fault diagnosis 6.1.9)
Element faulty (blown).
(Refer fault diagnosis 6.1.9)
Identify fault and correct.
Replace.
(Refer service section 6.3.9)
Replace.
(Refer service section 6.3.11)
Replace.
(Refer service section 6.3.15)
NO TEMPERATURE
CONTROL (TEMPERATURE
OVERRUN)
Heating contactor faulty.
(Refer fault diagnosis 6.1.9)
Thermostat faulty.
(Refer fault diagnosis 6.1.10)
Replace.
(Refer service section 6.3.11)
Replace.
(Refer service section 6.3.9)