2
Installation
4
©
Moffat Ltd, January 2007
Revision 1/
Blue Seal Evolution Series Gas Salamander
3.
This appliance must be mounted onto a non-combustible wall or tailored stand, using the rear wall
bracket and spacing screws provided.
4.
Combustible walls must not protrude past the front of the appliance.
5.
This appliance must not be mounted on a combustible surface or metal surface, as radiated heat will
cause these surfaces to become extremely hot.
6.
Caution should be taken as intense heat is emitted at the bottom front of the appliance.
7. Components
having adjustments protected (e.g. paint sealed) by manufacturer are only allowed to
be adjusted by an authorised service agent. They are not to be adjusted by the installation person.
8.
The unit should be mounted under an extraction hood in compliance with all local regulations.
In the event that the unit is not mounted under an extraction hood, the installer must ensure
that all regulations are met and that there is an unobstructed minimum distance of 750mm
from the top surface of the unit to the ceiling, which must be of non-combustible material.
NOTE: Do not obstruct or block the appliances flue. Never directly connect a ventilation
system to the appliance flue outlet.
Clearances
NOTE: Only non-combustible materials can be used in close proximity to this appliance.
This unit must be installed on a non-combustible wall or tailored stand with the following clearances;
*
We recommend allowing a clearance of 100mm on either side of the appliance to allow access to the
side panels for servicing purposes.
**
Using the wall mounting accessories provided with this appliance.
*** Top clearance to ceiling is subject to all local regulation requirements.
Combustible Surface
Non-Combustible Surface
Left/Right hand side
100 mm
25 mm (*)
Rear
30 mm (**)
30 mm (**)
Top Clearance to:
- Extraction Hood
200 mm
750 mm
- Ceiling (***)