B
Appendix B: Gas Conversion
27
©
Moffat Ltd, January 2007
Revision 1/
Blue Seal Evolution Series Gas Salamander
Conversion Procedure
NOTE:
•
These conversions should only be carried out by qualified persons. All connections
must be checked for leaks before re-commissioning the appliance.
•
For all the following conversion instructions, the side panels have to be removed
(Remove the two screws at the bottom of each side panel).
•
All conversion details apply to both L/Hand and R/Hand burners.
•
For all relevant gas specifications refer to the table at the end of this section.
Main Burner Injectors
1.
Unscrew the main burner injectors (
1
/
2
” A/F).
2.
Determine the correct injector sizes for the corresponding gas
type from the rating plate affixed to the right hand side panel
front bottom corner.
3.
Replace with the correct size injectors.
Pilot Injectors
1.
Unscrew the cap from the rear of the pilot burners, and unscrew
the pilot injectors (taking care not to lose the springs).
2.
Determine the correct pilot injector sizes for the corresponding
gas from the rating plate affixed to the right hand side panel
front bottom corner.
3.
Replace with the correct size pilot injectors.
NOTE: Ensure that the Pilot Injectors are fully screwed in.
C
AUTION
:
Ensure that the Unit is isolated from the gas supply before commencing
servicing
Main Burner
Injector
Pilot Injector Cap
Fig B2
Fig B1