6
Service Procedures
18
©
Moffat Ltd, January 2007
Revision 1/
Blue Seal Evolution Series Gas Salamander
6.2.5 Main
burner injectors
6.2.6
Gas control valve
Figure 6.2.7
Figure 6.2.6
6.2.7
Gas control magnet
4) Holding the burner, remove the two screws
located in the control area which fix to the
burner flange. The burner can now be
removed.
Two
screws
Figure 6.2.4b
5) Replace and reassemble in reverse order
1) Remove the side panel (refer 6.1.2).
2) Unscrew the main burner injector.
Injector
Figure 6.2.6
3) Clean or replace injector and reassemble in
reverse order.
NOTE:
It is important that the injector aligns
centrally with the burner venturi.
1) Remove the side panel (refer 6.1.2), and re-
move the knob from the gas control.
2) Disconnect the thermocouple, pilot supply
tube, and main burner supply tube from the
gas control.
3) Undo the nut securing the gas control inlet to
the supply manifold.
4) Extract the gas control,
replace and
reassemble in reverse order.
1) Remove side panel (refer 6.1.1).
2) Unscrew the thermocouple from the rear of
the gas control.
3) Remove the rear nut from the gas control.
6) Extract gas magnet.
7) Replace and reassemble in reverse order.
Gas Control
Magnet
Rear Nut