2
Installation
5
©
Moffat Ltd, January 2007
Revision 1/
Blue Seal Evolution Series Gas Salamander
Wall Mounting (to non-combustible wall only)
1.
Fix the wall mounting bracket to the wall with six screws, in such a position that the top of the
bracket is level and at least 945mm (38”) above any surface beneath the unit. This will ensure that
the bottom of the Salamander is at least 600mm (24”) above any surface.
2.
Fit the two black plastic spacers to the top
rear corners of the unit. Leave them
unscrewed by approximately 5mm.
3.
Fit the two adjusting screws / bolts into the
nutserts at the bottom rear corners of the
unit. These should protrude approximately
30mm from the rear of the Salamander.
4.
Lift the Salamander onto the wall bracket,
lining up the black plastic spacers on the
salamander with the mounting notches in the
bracket.
5.
Lower the Salamander onto the mounting bracket.
6. Tighten the black spacers securely and adjust the
levelling screws/bolts to ensure that the unit is level.
~ 5mm
~30mm
Fig 1
Fig 2
Fig 3
Fig 4