background image

3

www.blueangelpumps.com

CJW Series

PIPING

Piping may be copper, steel, rigid PVC plastic or flexible polyethylene 
plastic.

 

Flexible pipe is not recommended on suction 

  pipe (inlet pipe).

The pipe must be clean and free of rust or scale. Use a pipe joint 
compound on the male threads of the metal pipe. Plumber’s seal tape 
should be used with plastic threads. All connections must be air tight to 
insure normal operation.
Slope all inlet piping upwards towards the pump to prevent trapping air. 
Unions or hose couplings can be installed near pump to facilitate removal 
for servicing or storage. A rubber hose installed between the water 
system and the house piping will reduce the noise transmitted to the 
house.
Plastic pipe can be used on all installations except 2 in. deep well jet. 
The 2 in. deep well jet requires 1-1/4 in. galvanized steel pipe and special 
machined couplings (1-13/16 in. O. D.).
The galvanized steel pipe and the couplings restrict the flow of return 
water back to the jet unless the couplings are machined.

PIPE SIZES

Long horizontal pipe runs and an abundance of fittings and couplers 
decrease water pressure due to friction loss. See Chart 1, on page 5, to 
determine the proper pipe size. 

SHALLOW WELL INSTALLATION

A shallow well jet assembly can be used with the deep well pump when 
the pump is located 25 feet vertically of the water level (See converting 
to shallow well pump on page 6). Shallow well installations have only one 
pipe between the pump and water supply (Figure 2).
DRILLED WELL (FIGURE 16)
1.  Install a foot valve on the first section of pipe (Figure 2, Illustration A).
2.  Lower the pipe into the well.
3.  Add pipe until the foot valve is 5 feet below the lowest anticipated 

water level.

 

The foot valve should be at least 18 in. from the 

  bottom of the well or sand or sediment could be 

drawn into the system.

4.  After proper depth is reached, install a well seal or pitless adapter to 

support pipe and prevent surface. water and other contaminants 
from entering well.

5.  Slope the horizontal pipe upward toward the pump to eliminate 

trapping air. Sloping the pipe will also aid in priming the pump.

DRIVEN WELL
• 

Drive the point several feet below the water table.

NOTE: 

A packer type foot valve can be installed in the well (Figure 2, 

Illustration B). This type of foot valve allows the piping to be filled with 
water when priming and makes the inlet pipe much easier to test for 
leaks. Follow the manufacturer’s instructions when installing the packer 
type foot valve.
As an alternative, an in-line check valve can be used with a driven well 
(Figure 2, Illustration C). The pipe between the check valve and the water 
level will always be under a vacuum.

TO PUMP

WELL SEAL

FOOT VALVE

WELL CASING

TO PUMP

INLINE CHECK 

VALVE

PACKER TYPE 

FOOT VALVE

ILLUSTRATION A

ILLUSTRATION C

ILLUSTRATION B

Figure 2

TO PUMP

DRIVE POINT

DRIVE POINT

Содержание 100CJW

Страница 1: ...ious injury Disconnect power and release all pressure from the system before attempting to install service relocate or perform any maintenance Lock the power disconnect in the open off position Tag th...

Страница 2: ...is to store a quantity of water under pressure When full the tank contains approximately 2 3 water and 1 3 compressed air The compressed air forces the water out of the tank when a faucet is opened An...

Страница 3: ...5 feet vertically of the water level See converting to shallow well pump on page 6 Shallow well installations have only one pipe between the pump and water supply Figure 2 DRILLED WELL FIGURE 16 1 Ins...

Страница 4: ...E AND SPRING WITH TWO PIPE JET FIGURE 16 ON PAGE 10 1 Install a 1 1 4 in foot valve not included to the jet body A 1 1 4 in coupling is required to connect the larger pipe to the jet assembly 2 Connec...

Страница 5: ...TANK FIGURE 7 1 Check tank pre charge using a tire pressure gauge Set air pressure in tank to 28 psi which is 2 psi below pressure switch cut in level An air valve is located on the side and will acc...

Страница 6: ...re used run a wire directly to the metal well casing or use a ground electrode furnished by the power company There is only one proper ground terminal on the unit The terminal is located under the pre...

Страница 7: ...INTENANCE Disconnect power and release all pressure from the system before attempting to install service relocate or perform any maintenance Lock the power disconnect in the open off position Tag the...

Страница 8: ...y attention to how the original shaft seal is installed before disassembly 10 Remove the shaft seal from the impeller make sure the stainless steel sleeve comes off the impeller all you should see on...

Страница 9: ...plastic cap over the motor shaft end 21 Reassemble the diffuser make sure the arrow indicating the top is pointed toward the top of the pump torque the two screws to 30 10 inch pounds 22 Using the 4 c...

Страница 10: ...in D DRIVEN WELL Pipe with a pointed screen is driven into the ground below the water table The depth is usually less than 50 feet Available diameters are 1 through 2 E DRILLED WELL A hole bored into...

Страница 11: ...ace as necessary 6 Clogged nozzle deep well 6 Pull jet and clear obstruction 7 Air volume control diaphragm ruptured 7 Replace air volume control See Page 6 8 Foot valve may be clogged or stuck closed...

Страница 12: ...f any Part description and number as shown in parts list Address parts correspondence to Wayne Water Systems 101 Production Drive Harrison OH 45030 U S A 13 REPLACEMENT PARTS LIST Ref No Part Number f...

Страница 13: ...528 384 588 444 330 264 234 Jet Diameter Pump Model No Jet Assembly No Vertical Distance to Pumping Level 30 40 50 60 70 80 90 100 Output in Gallons Per Hour GPH 2 in 50CJW 50CJW 56319 55462 620 590...

Страница 14: ...14 Operating Instructions and Parts Manual NOTES www blueangelpumps com...

Страница 15: ...15 NOTES www blueangelpumps com CJW Series...

Страница 16: ...HATSOEVER IS EXCLUDED Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the above lim i...

Страница 17: ...al manipular este producto y l vese las manos despu s de manipularlo SEGURIDAD GENERAL 1 Lea con atenci n el manual de instrucciones incluido con este producto Familiar cese bien con los controles y...

Страница 18: ...PRE INSTALACI N FUENTES DE SUMINISTRO DE AGUA Las posibles fuentes de suministro de agua se ilustran en la Figurra 16 en la p gina 27 Se pueden clasificar en dos categor as AGUAS DE SUPERFICIE Agua de...

Страница 19: ...ndo se necesite dar servicio o almacenarlas Una manguera de caucho instalada entre el sistema de agua y la tuber a de la casa reducir el ruido que se transmite a la casa Se pueden usar tuber as de pl...

Страница 20: ...siempre sumergida Figura 3 Eyeccion de Chorro por Dos Tubos CUERPO DEL EYECTOR DE CHORRO V LVULA DE ASPIRACI N TUBER A DE 3 2 CM 2 54 CM 1 PULG PIPE TUBER A DE 3 2 CM Figura 4 Chorro de 1 Tubo TAMP N...

Страница 21: ...ecci n del tubo y baje el eyector de chorro dentro del pozo 4 Agregue tuber a hasta que el eyector de chorro est entre 1 52 y 4 57 m 5 y 15 pies por debajo del nivel de agua m s bajo que se anticipa N...

Страница 22: ...ores Seleccione los alambres y el fusible del tama o adecuado Tabla 2 Para la protecci n del circuito del motor se recomiendan los fusibles que interrumpen por un tiempo en vez de los fusibles convenc...

Страница 23: ...el motor y vuelva a llenar la bomba con agua El tiempo necesario para cebar es proporcional a la cantidad de agua en la tuber a de ingreso No permita que la bomba se caliente 6 Deje que el sistema fun...

Страница 24: ...conectar la corriente el ctrica a la bomba NOTA Conforme la bomba vuelve a llenar el tanque con agua el control de volumen de aire suministra al tanque la relaci n adecuada de aire y agua para que el...

Страница 25: ...mpulsor sobre el eje del motor apriete a mano Lubrique la nariz del impulsor con lubricante seguro para agua potable 20 Vuelva a colocar la tapa de pl stico sobre el extremo del eje del motor 21 Vuelv...

Страница 26: ...Sp 26 Manual de instrucciones de funcionamiento y piezas de repuesto NOTAS www blueangelpumps com...

Страница 27: ...rra por debajo de la capa fre tica La profundidad por lo general es menor a 15 25 m 50 pies Los di metros comunes fluct an entre 2 5 cm 1 y 5 1 cm 2 E POZO PERFORADO Un hoyo perforado en la tierra con...

Страница 28: ...a de la bomba 1 Baje m s el tubo de succi n dentro del pozo 2 La v lvula de control est demasiado abierta pozos profundos 2 Ajuste la v lvula de control o repita el procedimiento de cebado 3 Al cebar...

Страница 29: ...nectado a la salida incorrecta de la bomba 3 Mueva a la apertura correcta de la bomba 4 Precarga de tanqueincorrecta Tanque precargado 4 Agregue o quite aire cuanto sea necesario 5 Diafragma o bolsa r...

Страница 30: ...respondencia a N mero del modelo BLue Angel Pumps C digo impreso 101 Production Drive Descripci n y n mero del repuesto seg n la lista de repuestos Harrison OH 45030 U S A LISTA DE PARTES DE REPARACI...

Страница 31: ...2673 2018 1500 1200 1064 Di metro del Charro Modelo de Bomba No Ensamblado del Chorro No Distancia Vertical al Nivel de Bombeo En Metres 9 1 12 2 15 2 18 3 21 4 24 4 27 4 30 5 Entrega en Litros por Ho...

Страница 32: ...EXCLUS Certaines Provinces n autorisent pas de limites de dur e pour les garanties implicites ni l exclusion ni la limite des dommages fortuits ou indirects Les limites pr c dentes peuvent donc ne pa...

Отзывы: