Anti-dither: Here you can set anti-dither time. The value ranges from 5 to 600s. The anti-dither
time refers to the alarm signal lasts time. It can be seem as the alarm signal activation stays such
as the buzzer, tour, PTZ activation, snapshot, channel record. The stay time here does not include
the latch time. During the alarm process, the alarm signal can begin an anti-dither time if system
detects the local alarm again. The screen prompt, alarm upload, email and etc will not be
activated. For example, if you set the anti-dither time as 10 second, you can see the each
activation may last 10s if the local alarm is activated. During the process, if system detects
another local alarm signal at the fifth second, the buzzer, tour, PTZ
activation, snapshot, record
channel will begin another 10s while the screen prompt, alarm upload, email will not be
activated again. After 10s, if system detects another alarm signal, it can generate an alarm since
the anti-dither time is out.
Alarm output: The number here is the device alarm output port. You can select the
corresponding ports(s) so that system can activate the corresponding alarm device(s) when an
alarm occurred.
Latch: When the anti-dither time ended, the channel alarm you select in the alarm output may
last the specified period. The value ranges from 1 to 300 seconds. This function is not for other
alarm activation operations. The latch is still valid even you disable the alarm event function
directly.
Show message: System can pop up a message to alarm you in the local host screen if you
enabled this function.
Alarm upload: System can upload the alarm signal to the network (including alarm
center and the WEB) if you enabled current function. System only uploads the alarm
channel status. You can go to the WEB and then go to the Alarm interface to set
alarm event and alarm operation. Please go to the Network interface to set alarm
center information.
Send email: System can send out the alarm signal via the email to alert you when alarm occurs.
Once you enable the snap function, system can also send out an image as the attachment.
Please go to the Main Menu->Setting ->Network->Email interface to set.
Record channel: you can select proper channel to record alarm video (Multiple choices).
You need to set alarm record mode as Schedule in Record interface (Main Menu-
>Advanced->Record). Please note the manual record has the highest priority. System record
all the time no matter there is an alarm or not if you select Manual mode.
Now you can go to the Schedule interface (Main Menu->Setting->Schedule) to set the
record type, corresponding channel number, week and date. You can select the record
type:Regular/MD/Alarm/MD&Alarm. Please note, you cannot select the MD&Alarm and
MD(or Alarm) at the same time.
Now you can go to the Encode interface to select the alarm record and set the encode
parameter (Main Menu->Setting->Encode).
Finally, you can set the alarm input as the local alarm and then select the record channel.
The select channel begins alarm record when an alarm occurred. Please note system begins
the alarm record instead of the MD record if the local alarm and MD event occurred at the
same time.
Tour: Here you can enable tour function when an alarm occurs. System supports 1/8-window
tour. Please go to chapter4.3.6.2 Display for tour interval setup. Please note the tour setup here
has higher priority than the tour setup you set in the Display interface. Once there two tours are
both enabled, system can enable the alarm tour as you set here when an alarm occurred. If there
is no alarm, system implements the tour setup in the Display interface.
Snapshot: You can enable this function to snapshot image when an alarm occurs.
Buzzer: Highlight the icon to enable this function. The buzzer beeps when an alarm occurs.
Please highlight icon
to select the corresponding function. After setting all the
setups please click save button.