HDC-5016 IP to QAM Modulator User Manual
Date 29. Dezember 2017
BLANKOM-HDC-5016_IP2QAM-modulator-V1.1-RR-12-2017.docx
27
You should mix and balance them to both outputs to avoid accidently overloading of GbE
devices/ Interfaces:
NullPkt Filter will make VBR-streams out of the CBR which contains the PID 8192dec to safe some
IP bandwidth. Which might be not a good idea if you transfer this stream to a sub-headend where
a more or less stupid IP2QAM Modulator is installed which expects DVB-TP conform MPTS as CBR.
System → Network:
Selecting ‘Network’, will enter the menu as shown in Figure-13 where you can set/change
network parameters.
Figure-13
Remark:
The 2x RJ45 Data-Ports 1+2 have the same basic IP address!!! Scrambler connection can
be set here as well which needs to correspond with the external CA-Server and its IP address as