1.5 Specifications 

Input

 

Input 

512×2 IP input, 2x 100/1000M Ethernet Port   

Transport Protocol 

TS  over  UDP/RTP/RTSP,  unicast  and  multicast, 
IGMP V2/V3 

Transmission Rate 

max 840Mbps for each GE input 

Mux

 

Input Channel 

1024 

Output Channel 

16 

Max PIDs 

180 per channel 

Functions 

PID remapping (auto / manually optional) 

PCR accurate adjusting 

PSI/SI table automatically generating 

Encryption 
Parameters

 

Max simulscrypt CA 

CA Standard 

ETR289, ETSI 101 197, ETSI 103 197 

Connection   

Local/remote connection 

Modulation   
Parameters

 

QAM Channel 

16 non-adjacent carrier 

Modulation Standard 

EN300 429/ITU-T J.83A/B 

Symbol Rate 

5.0...7.0 Msps, 1 kSps steps 

Constellation   

16, 32, 64, 128, 256QAM 

FEC 

RS (204, 188) 

RF Output

 

Interface   

1  F-type  output  port  for  16  QAM  ch,  75Ω 

impedance 

RF Range 

50...960 MHz, 1kHz steps 

Output Level   

-20 dBm...+10 dBm (87...117 dbµV), 0.1dB steps 

MER 

≥ 40dB 

ACLR 

-60 dBc 

TS output

 

16 MPTS IP output over UDP/RTP/RTSP, unicast/multicast,   

2x100/1000M GbEthernet Ports 

System

 

Network management software (NMS) support (Front 100BaseT) 

General

 

Dimensions 

420 × 440 × 44.5mm (WxLxH) 

Weight   

3kg 

Temperature   

0...45

    (operation), -20...80

    (storage) 

Power Supply 

AC  100V±10%,  50/60Hz  or  AC  220V±10%, 
50/60Hz 

Consumption   

15.4W 

 

 

Содержание HDC 5016

Страница 1: ...HDC 5016 IP to 16 QAM Modulator EDGE QAM User Manual SW Version 08 60 17 Build 271 00 Nov 21 2017 HW version 0 0 1 0 Web NMS version 1 51...

Страница 2: ...OUNDING 4 3 2 4 DEVICE GROUNDING 5 3 3 WIRE CONNECTIONS 5 3 3 1 POWER CORD CONNECTION 5 3 3 2 SIGNAL AND NETWORK MANAGEMENT NMS CABLE CONNECTION 5 Chapter 4 Web NMS Management 5 4 1 LOGIN 5 4 2 OPERAT...

Страница 3: ...acterized with high integration level high performance and a reasonable price 1 2 Key Features 2 GE input RJ45 Input up to 1024 channels TS over UDP RTP unicast and multicast IGMP v2 v3 Max 840 Mbps f...

Страница 4: ...Manual Date 29 Dezember 2017 BLANKOM HDC 5016_IP2QAM modulator V1 1 RR 12 2017 docx 1 1 3 1 Application Example Master Slave System 1 4 Agile Channel Setting Example This EDGE QAM can be used with ag...

Страница 5: ...R289 ETSI 101 197 ETSI 103 197 Connection Local remote connection Modulation Parameters QAM Channel 16 non adjacent carrier Modulation Standard EN300 429 ITU T J 83A B Symbol Rate 5 0 7 0 Msps 1 kSps...

Страница 6: ...en you opens the package of the device it is necessary to check items according to packing list Normally it should include the following items HDC 5016 IP QAM Modulator User s Manual online download f...

Страница 7: ...any other device as part of grounding electric circuit The area of the conduction between grounding wire and device s frame should be no less than 25mm2 3 2 3 Frame Grounding All the machine frames sh...

Страница 8: ...e the connection of input signal cable and the connection of output signal cable Please use at least CAT 5 STP RJ45 LAN Cable for the management port and CAT 6 DSTP for the streaming data ports to avo...

Страница 9: ...ple EIT and SDT PMT Information can be grabbed from https www dvb org standards 4 2 1 Summary When the login has been confirmed it displays the summary status as in Figure 2 Figure 2 4 2 1 1 Setting D...

Страница 10: ...for European NTP Server addresses But first set the time zone please first set time zone than config NTP Server And you are done but your Device need a connection to these NTP addresses Local Gateway...

Страница 11: ...bled recommended for pass through To refresh the input program information To refresh the output program information Select one input program first and click this button to transfer the selected progr...

Страница 12: ...017 BLANKOM HDC 5016_IP2QAM modulator V1 1 RR 12 2017 docx 9 Figure 6 General From the menu bar on the upper side of the web frame selecting General displays the interface where you can set parameters...

Страница 13: ...American DVB C ATSC norms only and can be skipped in normal DVB C Annex A C modes PID Bypass From the menu on up side of the webframe selecting PID Bypass opens the menu to add the PIDs which need to...

Страница 14: ...en for scrambling with up to 4 different CAS as simulcrypt usage Of course you ll need these CA Servers and there connection to the device by the NMS Ethernet port to exchange the common Control Word...

Страница 15: ...r Manual Date 29 Dezember 2017 BLANKOM HDC 5016_IP2QAM modulator V1 1 RR 12 2017 docx 12 Add Input by pressing the a popup pops up add it and after a few sec The datarate is shown And parse the conten...

Страница 16: ...emark The Output max Data rate depends on the modulator output settings of this QAM channel 256QAM SR 7000 51Mb s These settings can be well prepared before you configure the Input TS in the Modulator...

Страница 17: ...w o any modification to the TS QAM output This would pass the whole content to the output QAM IP MPTS out TSID and ONID should be already well pre prepared and set according to your needs in the Mast...

Страница 18: ...well The NIT will be passed as well if containing but It might be a wrong one from a SAT frequency which is of course not valid for a cable TV network Other Tables might also not been valid anymore b...

Страница 19: ...RR 12 2017 docx 16 OUT We must filter out the invalid NIT but this is not possible when full pass through is selected Also EIT others should be erased as well as the invalid BAT and CAT Even trying to...

Страница 20: ...QAM modulator V1 1 RR 12 2017 docx 17 So the pass through is only worth for Master Slave HE designs like shown on page 2 To be used in SUB Headends Even manually add the services does not change anyth...

Страница 21: ...it manually And the EIT is here BUT also the EIT Other table which probably will not be conform with our other channel s which we are creating here and do not take from SAT or from the IP Anyway the S...

Страница 22: ...DC 5016_IP2QAM modulator V1 1 RR 12 2017 docx 19 Than transfer it to the output window right Single streams can be added to a TS like REMARK Single streams often do not contain EIT EPG PID s So an EIT...

Страница 23: ...ers are used in the ATSC DVB C Annex B ITU J standard and should be ignored by the normal DVB Annex A C receivers Same for the General item VCT LCN s in the NIT and other values should be set after al...

Страница 24: ...sing the CA Filter will remove ECM PID s as well Yes Minor Mayor channel Numbers are an extension in the ATSC tables and not relevant for normal DVB operating so will be ignored Service name and other...

Страница 25: ...QAM Mode Annex A C Normal DVB Annex B US Norm mode 16 256 QAM and other values This Quick setup configures adjacent channel from a start frequency To individually configure the other 63 channels set...

Страница 26: ...x 23 DVB T2 channels OTA would might interfere or we can integrate them into our network So we should exactly skip these in our DVB C channels Example Region northern Germany ARD Mux ch23 490 MHz ZDF...

Страница 27: ...BLANKOM HDC 5016_IP2QAM modulator V1 1 RR 12 2017 docx 24 So first we correct the quick start frequency to 354 MHz as center frequency And we are sure to not interfere to DVB T2 After all IN and Outp...

Страница 28: ...elling as well Parameters IP Stream This device supports TS to output in IP 16 MPTS format through the DATA port Selecting left the IP Stream it will open this setting overview shown as Figure 12 to s...

Страница 29: ...rroring the MPTS streams to i e 2 different physical IP Ring directions Modify it to your needs Quick setup also configs an automatic counting and increasing of Port s RTP is more reliable for longer...

Страница 30: ...safe some IP bandwidth Which might be not a good idea if you transfer this stream to a sub headend where a more or less stupid IP2QAM Modulator is installed which expects DVB TP conform MPTS as CBR Sy...

Страница 31: ...rom the left side menu of the webpage selecting Password will display the screen as Figure 14 where you are able to set change the login account and password for the web access by the NMS Port Figure...

Страница 32: ...e From the menu on left side of the webpage selecting Firmware you ll enter the screen as in Figure 16 where to update firmware for the device Figure 16 System Log From the menu on left side of the we...

Страница 33: ...cted Frequently switching on off device is prohibited the interval between every switching on off must greater than 10 seconds Conditions need to unplug power cord Power cord or socket damaged Any liq...

Страница 34: ...ontend used and the operating adjustments the SAT RF input ports carrying DC Voltage 13V 18V max 400 mA By connecting a mains cable the device can become functional without any auxiliary appliances Th...

Страница 35: ...the user is familiar with all abbreviations mentioned in this manual Contact IRENIS GmbH Owiesenkehre 1 D 22177 Hamburg Germany Managing Director Dipl Ing Riccardo Rossini Commercial Register HRB 130...

Отзывы: