OPERATING INSTRUCTIONS
Ensure that all installation and operating instructions and safety
precautions are understood and carefully followed by anyone installing or
using the charger. Follow the steps outlined in “Important Safety
Instructions” at the front of this manual.
Charge Rate Selection
After charger clamps are correctly connected, plug in the charger to a 120 volt AC
outlet and the charger will show a circulating pattern on the Digital Display,
indicating power has been applied. Select the proper charge current rate based
on battery size. Press the 4/10/20/40 AMP button and the charger will begin
charging at 4 amps. Pressing the 4/10/20/40 AMP button again will advance the
charge rate to 10 amps, again to 20 amps, and again to 40 amps. Pressing the
switch again will turn OFF the charger output and the display will show “000.”
Note:
The only time the selected charge rate does not display at the full selected rate is
when the battery is nearly full and charging at either step two or three. The display
will be showing a reduced charge rate. To return to 4A, press the 4/10/20/40 AMP
button. When the battery is fully charged, the charging complete and “FUL” is
displayed on the Digital Display.
WARNING
If Digital Display shows “F02”, the connection to the battery terminals is
bad. Follow the steps outlined in “Important Safety Instructions” at the front
of this manual to disconnect, clean battery terminals, then reconnect.
If Digital Display shows “F06”, the Red (POSITIVE) and Black (NEGATIVE)
clamps are incorrectly connected to battery terminals. Follow the steps
outlined in “Important Safety Instructions” at the front of this manual to
disconnect, then reconnect in correct polarity.
Charging the Battery
1. Press Battery Type selector until desired battery type LED lights.
Note:
The default selection is “GEL” type battery.
2. Press 4/10/20/40 AMP button to begin charging at the 4 amp rate; the unit
sounds a beep and the charging current LED lights. The charger starts
charging at 4 amp rate automatically if 4/10/20/40 AMP button is not pressed
within 3 minutes after applying AC power.
If the Display on the charger varies between “F03” and the amp rate, the
battery is sulfated and the charger is trying to give it some charge. If after
approximately 2 hours the display just shows “F03”, then the battery will not
charge.
Charger occasionally sounds a beep and displays “0.0” during self-test or
charging stage changes.
3. Pressing the 4/10/20/40 AMP button again advances charging rate to 10
amps, pressing once more advances charging rate to 20 amps, and again to
40 amps. (Pressing the button again will turn OFF the charger output and the
Display will show “000”.) This selection and actual battery charge rate are
monitored by the microprocessor, and the unit will stop charging if the
selected rate is too fast or too slow for battery size or condition.
As the battery nears full charge capacity, the unit’s output will automatically
drop to a lower charge rate.
4
INDICATOR:
Large (.375”) 3-Character Digital Display
in the upper left of the control panel
indicates the various conditions and/or status codes:
Status Codes
are described in the following chart and on the back of charger.
CONTROL PANEL LED INDICATORS:
WET —
lights when battery type selector is on WET battery type
GEL —
lights when battery type selector is on GEL battery type
AGM —
lights when battery type selector is on AGM battery type.
Float Charge —
lights when automatic charge monitoring is active. This feature
allows a battery to maintain its charge over long periods of non-use. If there is any
loss of power to the charger once power is restored charger will automatically
return to the default settings. Battery selector type would be “GEL”.
Battery Voltage —
lights when battery voltage is displayed.
Alternator Good —
lights when load or not load checks show the alternator is
keeping up with the electrical load.
BUTTON (TO THE RIGHT OF LEDS):
Equalize —
a recessed button used to start the equalization process.
AC POWER INDICATOR -
When connected to an AC outlet, digital display shows circulating pattern to
indicate power is on. Disconnect charger after use.
FAULT CODES
OPERATION CODES
F01
F02
F03
F04
F05
F06
F07
000
FUL
INTERNAL SHORTED CELL BATTERY -
Cannot be charged. Have battery checked by certified auto service center.
EXCESSIVE LOAD ON BATTERY WHILE CHARGING -
Check load.
BAD BATTERY CONNECTION -
Check battery connection.
BATTERY VOLTAGE TOO LOW TO ACCEPT CHARGE -
Have battery checked by certified auto service center.
BATTERY RECONDITIONING -
(The letters
DES
will display for the first 3 seconds.)
INTERNAL OPEN CELL -
Have battery checked by certified auto service center.
SULFATED CONDITION -
Battery needs to be reconditioned. See manual.
OVERHEATED CONDITION -
Disconnect charger and allow to cool for 30 min., check for ample ventilation.
REVERSE POLARITY
ALTERNATOR OUTPUT IS OUT OF TYPICAL OPERATION RANGE
ALTERNATOR VOLTAGE CHECK
CHARGER STANDBY
BATTERY FULLY CHARGED
OVERTIME CONDITION -
Battery will not accept a charge after 18 hours of continuous charging. Battery may have
internal damage. Have battery checked by certified auto center.
BATTERY CHARGE RATE IS SET TOO LOW -
Set charger to higher charge rate. See manual.