60
3.
Use the
keys to move the cursor to the
CURVE
field
and use the rotary knob to select the desired curve number. The
curve number can be
1-16
or
TABLE
(table of up to 1024 I-V
points.)
4.
Once again, use the
keys to move the cursor to the
EDIT
field and press
. The following display will be shown:
5.
Use the
keys to move the cursor through the four
parameter settings. Use the numerical keys to enter parameter
values and press
to confirm each of the four parameter
settings.
Press
several times to exit the menu setting.
3.8
Program Function
Overview
The PVS has a Program feature that allows storing of programs into
internal non-volatile memory and recalling and running them per
configured parameters. A total of 100 steps can be configured for each
program, and a total of 9 programs are available for storage.
Additionally, multiple programs or all 9 programs can be saved into a
program configuration, where each program configuration allows
running one program after another or repeat a finite number of times.
This allows for a total of 900 steps in one configuration. Below is an