Serial Trigger and Decode
81
7.5.2 LIN Trigger
This section provides a brief introduction and description for the operation of the LIN trigger.
Trigger Condition
•
Break
— the oscilloscope will be triggered at the position of break field’s break delimiter.
•
ID
(Frame ID) — the oscilloscope will be triggered at the position of identifier field’s stop bit, if the value of a frame’s
ID is equal to specified value. (Note: If the data’s value is 0xXX, any data value will be matched)
•
ID + Data
(Frame ID and Data) — the oscilloscope triggers when a frame with an ID and data equal to the selected
values is detected. Use the
Universal Knob
to select the value for the ID, Data1 and Data2.
a. The ID’s value is the same as set value.
b. If you have set either Data1’s or Data2’s value, and the signal has a data is the same as that value. If you have
set both Data1’s and Data2’s value, the signal should has two consecutive data, the first data’s value is Data1,
second data value is Data2.
Note:
If the data’s value is 0xXX, any data value will be matched
•
Data Error
—the oscilloscope will be triggered when errors (such as ID check error, checksum error, sync byte field
error) are detected.
Operation Steps
• Touch
Setup
key to enter the
TRIGGER
function menu.
• Touch
Type
and select
Serial
.
• Touch
Protocol
and select
I2C
.
• Touch
Trigger Setting
to enter
LIN TRIG SET
menu.
• Touch
Condition
and select the trigger condition by
Universal Knob
:
• If you select
ID
condition:
– Touch
ID
and set its value by turning the
Universal Knob
.
• If you select
ID+DATA
condition:
– Touch
ID
and set its value by turning the
Universal Knob
.
– Touch
DATA1
and set its value by turning the Universal Knob.
– Touch
DATA2
and set its value by turning the Universal Knob.