Trigger
46
6.7.3
The
Pulse Trigger
type triggers on the positive or negative pulse with a specified width.
Figure 6.11
Pulse Trigger
1. Press the Setup key to enter the
Trigger Menu
.
2. Press the
Type
softkey to view the available trigger types.
3. Turn the Universal Knob
4. Select
Pulse
and push the Universal Knob to select the trigger source.
5. Turn the Trigger Level Knob to adjust the trigger level to the desired place.
6. Press the
Polarity
softkey to toggle between
Positive
and
Negative
pulse.
7. Press the
Limit Range
softkey and turn the Universal Knob to select the desired condition.
•
<= (less than a time value)
: Trigger when the positive or negative pulse time of the input signal is lower than
the specified time value. For example, for a positive pulse, if you set t (pulse real width) 100ns, the waveform
will trigger.
Figure 6.12
Less than a Time Value
•
>= (greater than a time value)
: Trigger when the positive or negative pulse time of the input signal is greater
than the specified time value. For example, for a positive pulse, if you set t (pulse real width) 100ns, the waveform
will trigger.
Figure 6.13
Greater than a Time Value
•
[- -.- -] (within a range of time value)
: Trigger when the positive or negative pulse time of the input signal is
greater than the specified lower limit of time and lower than the specified upper limit of time value.