8
www.bitrek.com.ua
[email protected]
+380 44 507 02 07
Table 2 - Designation of contact elements
No.
Colour
Name of
contact
Type of
signal
Purpose of contact
1
Black
GND
Power
supply
Common wire (ground)
2
-
N/C
-
Not connected
3
-
N/C
-
Not connected
4
White
AN in 1
Input
Analog input No. 1
5
Pink
Out 1
Output
Discrete output No. 1
6
-
N/C
-
Not connected
7
-
N/C
-
Not connected
8
Red
+ V in
-
"+" of on-board power
supply (rated voltage of
12 V or 24 V)
9
-
N/C
-
Not connected
10
-
N/C
-
Not connected
11
-
N/C
-
Not connected
12
-
N/C
-
Not connected
13
-
N/C
-
Not connected
14
-
N/C
-
Not connected
Assembly, commissioning
Assembly recommendations
Zone of installation of tracking device shall enable the connecting of the
pin to it and disable the possibility of accidental damage to the device,
moisture, impact of high temperature. Recommended location for installation
in the vehicle is an empty space under the dashboard inside the vehicle; in
addition, the device shall be placed in a way ensuring the upper side with
LEDs to face up.
The body of the device contains grooves for easy fastening with plastic
ties.
Electrical connections
Power supply wires are laid through the maintenance holes in the body
of the vehicle from the regular battery location to the place of installation of
the tracking device. Power wires are connected to the corresponding battery
terminals.