18
www.bitrek.com.ua
[email protected]
+380 44 507 02 07
Number
of
parameter
Description
Possible values
0
Enable/disable I/O element
0 - disabled; 1 - enabled
1
Priority of I/O element at
transmission
0 - low; 1 - high
2
Upper limit
(depending on the type of I/O
element)
3
Lower limit
(depending on the type of I/O
element)
Setting of the type of the
generated event
1.
entering the range;
2.
leaving the range;
3.
returning/leaving to/of the
range
monitoring;
4.
moni entering the
range;
5.
moni leaving the
range;
6.
- moni
returning/leaving to/of the
range;
7.
generation of the event to
change the input value to
a predetermined value;
8.
- generation of the event
to change the input value
to a predetermined value
+ monitoring.
5
Averaging constant
From 0 and higher
Notes to Table 5:
Parameter 0 - on/off of transmission of I/O element to the server.
Parameter 1 - Priority: low/high. While selecting "Priority: low" - data of the
sensor will be sent to the server with the following data packet. While
selecting "Priority: high" data of the sensor will be sent to the server at the
earliest possible opportunity.
Parameter 2 - Upper limit - set the upper limit of the I/O element.
Parameter 3 - Lower limit - set the lower limit of the I/O element.
Parameter 4 - Set the type of the generated event:
0 - Returning to the range.
At a specific range of sensor values (range of values is specified as