PSV
U, mV
t, s
10 000
Figure 6 - Generation of event by leaving the range.
2 - Returning/leaving to/of the range.
Event is generated every time when the actual value of the sensor is out
of the limits of the predetermined range.
Example: The lower voltage limit is set to 5 V (5 000 mV) , the upper
limit is set to 10 V (10 000 mV). When the actual voltage crosses limits
of the specified range, then event is generated (see Figure 7).
PSV
U, mV
t, s
10 000
5 000
Figure 7 - Generation of event by returning/leaving to/of the range.
3 - Monitoring. When this mode is selected, data will be transmitted
continuously, the events will not be generated.
4 - Moni entering the range. When there is generated the event
after entering the range, the actual value of the sensor starts to be
transmitted to the server in the monitoring mode.
5 - Moni leaving the range. When there is generated the event
after leaving the range, the actual value of the sensor starts to be