INSTALLATION, OPERATION AND MAINTENANCE MANUAL
BiSolid Saver OM-BSSV00/08/2012/EN
6
Information about all product groups (modifications) is presented in this manual for operation,
installation and maintenance.
1.5. BOILER OVERALL DIMENSIONS
Overall dimensions of the boiler BiSolid Saver are presented in Figure 1 and Table 2.
Figure 1. Overall dimensions of boiler BiSolid Saver
60
G
D
F
A
C
100
160
B
7
8
4
5
3
2
1
E
9
6
1 – Fuel feeding door
2 – Secondary air flap
3 – Soot cleaning door
4 – Grill lever
5 – Ash cleaning door
6 – Pipes to DBV1 – not standard part of
the boiler delivery kit
7 – DBV1 – two-way cooling safety valve
– not standard part of the boiler delivery kit
8 – TRV – temperature valve regulating
the boiler heating output
9 – Heat-exchanger cover with initial firing
flap
Table 2. Overall dimensions of boiler BiSolid Saver
BiSolid
Parameter
Notation
Dimension
Saver 25
Saver 40
Boiler height
A
mm
900
1100
Boiler length
B
mm
920
920
Boiler width
C
mm
720
720
Heating water outlet flange height
D
mm
1030
1030
Flue pipe axis height
E
mm
905
890
Heating water inlet flange height
F
mm
215
215
Heating water outlet distance
G
mm
290
340
Inlet and outlet muff
-
1 ½”
1 ½”
Flue pipe diameter (outer)_
mm
130
160