INSTALLATION, OPERATION AND MAINTENANCE MANUAL
BiSolid Saver OM-BSSV00/08/2012/EN
7
1.6. BOILER SCHEMATIC CROSS-SECTION VIEW
Schematic cross-section view of boiler BiSolid Saver is presented in Figure 2.
Figure 2. Schematic cross-section view of boiler BiSolid Saver
1.Fuel hopper cover panel
2.Middle cover panel
3.Rear cover panel with flap
4.Flap with handle
5.Second flue gas pass (turbolators position)
6.Rear section
7.Hot water outlet
8.Flue pipe
Ф
150 mm
9.Isolation cover
10.Fireclay bricks
11.Cold water inlet
12.Draining muff
13.Cleaning cover
14.Bushes for legs
15.Bottom isolation
16.Moving grill
17.Ash tray
18.Grill handle
19.Flipping grill
20.Rotation axle shaft
21.Combustion chamber door
22.Air inlet flap (for dry wood)
23.Front cover panel
24.Dry wood hopper
25.Thermo-manometer gauge
The steel turbolators are optionally offered for every boiler from series BiSolid Saver W,
BiSolid Saver C and BiSolid Saver A and can be used in all operation modes.