INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Bisolid Automat OM-BAV05/02/2018/EN
52
6.11.4. COMMON SETTINGS
Table 14. Common settings of pellet burner
6.12. SMS COMMANDS
The GSM module is optional and it is connected to
„CON7
”
of the indicaiion board. When
available, the GSM symbol appears on the indication. The SMS commands should be with
Latin letters using only capital or only small letters.
Example: BSTOP and bstop - correct, Bstop - wrong.
Table 15. Description of pellet burner GSM control commands
BSTOP and BSTART commands have the same effect as
ON / OFF
button and when turned
on, the weekly program runs. In case of emergency, if no telephone number is recorded, a
check is performed for the last telephone number that has sent an SMS and if no such number
the notification is not sent. When SMS command is received, a reply SMS is sent to the
number that has sent the command.
Name
Indication
Limit
Factory
settings
Delay of response of the flow
sensor
In FC
1 – 240 s
30 s
Assignment of light sensor
Fire set
0 – 99 %
30 %
Assignment pump switch on
Tpump set
10 – 70 °C
40 °C
Pulse revolutions
Fan1 pulse/rev
0 - 12
0 - inactive
1
Name
Indication
Action
Stop
BSTOP
Stops the burner - identical to ON / OFF button
Start
BSTART
Starts the burner - identical to ON / OFF button
Current status
BINFO
Sends an SMS with the current status
Emergency phone
number
BPHONE
Records the telephone number from which the
message has been sent and in case of missing
flame, missing air flow or activated blocking
thermostat sends a notification.
Common Settings
FC delay
30 s
Fire set
30 %
Tpump set
40 °C
Pulse/rev
0