INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Bisolid Automat OM-BAV05/02/2018/EN
49
Table 9. Weekly timer setup parameters
To allow operation of the controller, a working interval should be set on one
of the four programs at least. When setting up identical starting and closing
time of the interval, the program is inactive.
Turning off a weekly program is indicated by
Pr.0
, and when in operation the number of the
active program is displayed (
Pr.1
–
Pr.4
).
The selection of a flashing period indicates the duration of the program. The selected program
can apply for only one day, for a period from Monday to Friday, Saturday and Sunday and for
the entire week. The flashing indicator shows the selected option.
6.10.3. ALARM MESSAGES
The presence of an alarm message during operation of the pellet burner is indicated by an
icon .
Table 10. Information for the alarm messages
OK
- normal condition,
Err
- alarm.
In case of a warning alarm message fault of pellet burner,
the user is obliged
to check for possible accumulation of fuel in the burner tube and fuel transport
auger and in the presence of fuel to remove it.
Name
Indication
Limit
Program number
Program
1 - 4
Interval
00:00
–
24:00
Day of the week
SuMoTuWeThFrSa
Su
–
Sa
(from Sunday to
Saturday)
Name
Indication
Status
Recovery
No flame
No Fire
OK / Err
Switch off and on
Risk of freezing
Low Tb
OK / Err
Increasing temperature
Overheating
(activated blocking
thermostat)
In BT
OK / Err
Switch off and on
No air flow (flow device) -
switch off pressure switch
or Hall sensor
In FC
OK / Err
Switch off and on
Alarm
No Fire
OK
Low Tb
OK
In BT
OK
In FC
OK