CB (E7) 06/2018
Page 16/174
1.8
Intended use
Series CB incubators are suitable for the cultivation of mammal cells under typical conditions of approx.
37 °C /
98.6°F
. The chamber permits setting defined pH conditions by common NaHCO
3
buffer systems
of commercial cell media by keeping an exact CO
2
atmosphere inside. The chambers guarantee high
humidity inside to avoid osmolarity increasing caused by the evaporation of the cell media.
With the chamber with O
2
control, a variable oxygen atmosphere can additionally influence the growth of
the cells.
The chambers are suitable for exact conditioning of harmless materials. Any possible solvent any solvent
must not be explosive and flammable. Components of the charging material must NOT form an explosive
mixture with air. The operating temperature must lie below the flash point or below the sublimation point
of the charging material. Any component of the charging material must NOT be able to release toxic
gases.
DANGER
Explosion or implosion hazard.
Danger of poisoning.
Danger of death.
∅
Do NOT introduce any substance combustible or explosive at working temperature into
the chamber, in particular no energy sources such as batteries or lithium-ion batteries.
∅
NO explosive dust or air-solvent mixture in the inner chamber.
∅
Do NOT introduce any substance which could lead to release of toxic gases.
Other applications are not approved.
Following the instructions in this operating manual and conducting regular maintenance work
(chap. 22.1) are part of the intended use.
The chambers are not classified as medical devices as defined by the Medical Device Directive
93/42/EEC.
Due to the special demands of the Medical Device Directive (MDD), these chambers are not
qualified for sterilization of medical devices as defined by the directive 93/42/EWG.
WARNING: If customer should use a BINDER chamber running in non-supervised
continuous operation, we strongly recommend in case of inclusion of irrecoverable specimen
or samples to split such specimen or samples and store them in at least two chambers, if this
is feasible.
The charging material shall not contain any corrosive ingredients that may damage the
machine components made of stainless steel, aluminum, and copper. Such ingredients
include in particular acids and halides. Any corrosive damage caused by such ingredients is
excluded from liability by BINDER GmbH.
In case of foreseeable use of the chamber there is no risk for the user through the integration of the
chamber into systems or by special environmental or operating conditions in the sense of EN 61010-
1:2010. For this, the intended use of the chamber and all its connections must be observed.