Pneumatic Motion Control System
4. CONNECT THE POWER CABLE
Standard Enclosure
Carefully remove the enclosure cover. Use a two conductor cable, 22 gage minimum, with an outside diameter
between 0.114 and 0.250 inch. Pass the cable through the bulkhead strain relief and connect to the
POWER
terminal block
(TB1) on the PCS circuit board (refer to illustration below). If a shield wire is used, twist the Ground wire and the
Shield wire together and connect to the Ground terminal (do not terminate the other side of the shield).
Set jumper J02 for 4-20 mA or 0-10 V control voltage input in accordance with the illustration above.
Refer to Appendix A for air and electrical connections to PFCN, PFC, and PT.
Option N
Connect a two conductor, 22 gage minimum shielded cable to the POWER terminal block (TB1) on the PCS
circuit board. Twist the ground and shield wire together and connect to the Ground terminal (do not terminate
the other side of the shield).
For best positioning results, consider using a precision relieving regulator and an air reservoir with a check
valve before the regulator to ensure that there are no pressure drops to the PCS system. You may want to
install mufflers into the exhaust ports of the valve manifold (the two outer ports). This will make the system
quieter during operation. Do not to use mufflers with low flow rates; that may slow the actuator.
TB4
TB1
TB2
TB3
Deadband set switch
Deadband adjustment
Decel adjustment
Zero adjustment
Span adjustment
You may adjust the jumper on
JO2 for 0-10V (left and center
terminals connected) or 4-20
mA (right and center terminals
connected) operation.
Do NOT change the jumper
JO1. This adapts the board for
use as PCS-4 through PCS-8
operation. Different valves
must be installed as well.