param. 1
param. 2
param. . . .
logic. 1
logic
logic. 2
logic. . . .
PRG
ITA
FRA
DEU
ENG
esp
OK
OK
OK
OK
OK
- +
- +
- +
- +
add. start
hidden button
release
ok 01
desired button
PRG.
read
erase 64
COD RX
1 A 9 C
OK
2 2 F D
OK
0 1
OK
+
/
-
01 t1
See PARAMETERS MENU
See LOGIC MENU
See RADIO MENU
radio
ACCESS TO MENUS
Cancel/return to main menu
Scroll up
end
end
end
end
end
language
default
Scroll down
Control unit software version
N. total manoeuvres (in tens)
N. manoeuvres since latest maintenance (in tens)
N. radio control devices memorised
Press the OK key
Description
STRT
STARTinput activation
STOP
STOP input activation
PHOT
PHOT input activation
Fltf
FAULT input activation for checked photocells
time
TIMER input activation
tTca
waiting time for automatic closing on TIMER release
BAR
EDGE input activated (obstacle alarm)
CLOS
CLOSE input activation
OPEN
OPEN input activation
Swo
barrier in opening position
Suc
barrier in closing position
REfo
reference input on opening activated
refc
reference input on closing activated
th
check on safety devices failed
AmP
ER0x
ER1x
ER2X
ampere-stop triggering (obstacle alarm)
Enc
encoder stopped detected (obstacle alarm)
Logic
35.40
Set torque threshold %
Maximum motor torque %
ER4x
EREF
check on motor control failed
power supply cables for motor or encoder signal reversed
error due to position references both active.
overload signal indication (the system completes the manoeuvre in progress
and does not allow new ones until the signal indication has been eliminated).
overload error (the system remains under protection lock until the error has
been corrected).