INSTALLATION MANUAL
TABLE “B” - LOGIC MENU - (
logic
)
Logic
default Definition
Description
tca
ON
Automatic
closing time
ON: Activates automatic closing
OFF: Excludes automatic closing
Note: automatic closing on TIMER release cannot be deactivated.
2 step
OFF
2-step logic
ON: Enables the 2-step logic (prevails over the “3-step logic”).
OFF: Disables the 2-step logic, activating the 4-step logic if the “3-step logic” is OFF.
3 step
ON
3-step logic
ON: Enables the 3-step logic (if the “2-step logic” is OFF).
OFF: Disables the 3-step logic, activating the 4-step logic if the “2-step logic” is OFF.
Response to the START impulse
Barrier
2 steps
3 steps
4 steps
closed
opens
opens
opens
on closing
stop
open
closes
closes
closes
on opening
stop + TCA
stop + TCA
after stop
opens
opens
opens
ibl open
ON
Opening Impulse
lock
ON: The Start impulse has no effect during the opening phase.
OFF: The Start impulse becomes effective during the opening phase.
ibl TCA
OFF
Impulse lock TCA ON: The Start impulse has no effect during the TCA dwell period.
OFF: The Start impulse becomes effective during the TCA dwell period.
pre-alar
OFF
Pre alarm
ON: The blinker comes on about 3 seconds before the motor starts.
OFF: The blinker comes on at the same time as the motor starts.
hold-to-run
OFF
Hold-to-run
control device
ON: Hold-to-run operation: the manoeuvre continues as long as the OPEN and CLOSE control keys
are kept pressed. The radio transmitter cannot be used.
OFF: Normal impulse operation.
fast cls
OFF
Rapid closing
ON: Closes barrier after photocell disengagement, before waiting for the end of the TCA (automatic
closing time) set.
OFF: Command not entered.
photc. open
ON
Photocells on
opening
ON: In case of obscuring, this excludes photocell operation on opening. During the closing phase, it
immediately reverses the motion.
OFF: In case of obscuring, the photocells are active both on opening and on closing. When a photocell
is obscured on closing, it reverses the motion only after the photocell is disengaged.
test phot
OFF
Photocell test
ON: Activates photocell check
OFF: Deactivates photocell check
inv. dir
OFF
Direction
Reversal
ON: For right-hand fitted barrier (see Par. Right-hand fitting)
OFF: For left-hand fitted barrier
IMPORTANT: Default has no effect on the logic.
ti er
OFF
TIMER OPEN
Special dip switch 1 on second-generation universal programmers.
ON: OPEN pressed for over 3s becomes TIMER
OFF: TIMER input disabled
alar sca
ON
SCA Alarm
Signaling output on second-generation universal programmers.
ON: The SCA contact (terminals 21-22) behaves as follows:
with barrier open and on opening: contact closed (warning light on)
with barrier closed:contact open: (warning light off)
on closing: intermittent contact (blinking)
OFF: The SCA contact closes according to the modes set by the Alarm Time parameter.
fixed code
OFF
Fixed code
ON: The receiver is configured for operation in fixed-code mode.
OFF: The receiver is configured for operation in rolling-code mode.
radio prog
ON
Radio transmitter
programming
ON: This enables transmitter storage via radio:
1 – First press the hidden key (P1) and then the normal key (T1, T2, T3 or T4) of a transmitter
already memorised in standard mode by means of the radio menu.
2 – Within 10s press the hidden key (P1) and the normal key (T1, T2, T3 or T4) of a transmitter to
be memorised.
The receiver exits the programming mode after 10s, other new transmitters can be entered before
the end of this time.
This mode does not require access to the control panel.
OFF: This disables transmitter storage via radio.
The transmitters can only be memorised using the appropriate Radio menu.
aster
OFF
Master/Slave
ON: The control panel is set as Master in a centralised connection.
OFF: The control panel is set as Slave in a centralised connection.