13
COMMANDS
ENGLISH
STANDARD Communication Protocol
R77.1
PHASE 1 CURRENT SAMPLES
Answer
format:
<STX><SP>514 characters** (128 samples per wave)<ETX><BCC>
**: The last two characters are reserved
R77.2
PHASE 2 CURRENT SAMPLES
Answer format:
<STX><SP>514 characters** (128 samples per wave)<ETX><BCC>
**: The last two characters are reserved
R77.3
PHASE 3 CURRENT SAMPLES
Answer format:
<STX><SP>514 characters** (128 samples per wave)<ETX><BCC>
**: The last two characters are reserved
R7F.001 INSTRUMENT
CONFIGURATION
Answer
format:
<STX>OA=02;OD=02;ID=04;SP=8;RAM=0128k;COM1<ETX><BCC>
OA
number of analog outputs *
OD
number of digital outputs
ID
number of digital inputs *
SP
number of set points (ENH)
RAM
detected
memory
COMx
used communication port (in the instrument)
R7F.002 FULLSCALE INFORMATION
Answer format:
<STX>KTA=0001;KTV=0001.000;FSV=433;FSV3=750;FSW=0433;FSW3=1299;MSA
=12;MSA3=12; MSN=12;MSV=1000;MSV3=1000;MSW=12000;MSW3=12000;FA=0
1;CSDO=1320;<ETX><BCC=72h>
R7F.008
INFORMATION ON R3D ANSWER FORMAT
Answer
format:
<STX> 00,10 01,10 02,10 03,10 04,10 05,10 06,10 08,20 09,20 0A,20 0B,20 10,13
11,13 12,13 13,13 18,21 19,21 1A,21 1B,21 20,22 21,22 22,22 23,22 28,23 29,23
2A,23 2B,23 30,24 31,25 34,11 39,22 3A,20 3B,10 3C,10<ETX><BCC=23h>
<STX> 00,10 01,10 02,10 03,10 04,10 05,10 06,10 08,20 09,20 0A,20 0B,20 0C,12
0D,12 0E,12 0F,20 10,13 11,13 12,13 13,13 FF,-- 15,13 16,13 17,13 18,21 19,21 1A,21
1B,21 20,22 21,22 22,22 23,22 28,23 29,23 2A,23 2B,23 2C,24 2D,24 1E,24 1F,24
30,24 31,25 33,25 1C,26 32,24 2E,25 2F,25 1D,26 34,11 36,12 37,12 38,12 FF,-- 3B,-
- <ETX><BCC=54h>
Where:
00
system voltage variable
,
separator between variable and measurement unit
10
measurement
unit
single
word:
10
Volt
11
dHz
12
dperc
13
COSØ
Command Description
UBN310
UBN315
UBN3080
UBN310
UBN315,
UBN3080