40
EXCLUSIVE
Parameter
Symbol
EXCLUSIVE
25C
EXCLUSIVE
30C
EXCLUSIVE
35C
Unit
Seasonal space heating energy efficiency class
-
A
A
A
-
Water heating energy efficiency class
-
A
A
A
-
Rated heat output
Pnominal
18
24
29
kW
Seasonal space heating energy efficiency
ηs
94
94
94
%
Useful heat output
At rated heat output and high-temperature regime (*)
P4
17.6
23.5
29.4
kW
At 30% of rated heat output and low-temperature re-
gime (**)
P1
5.9
7.9
9.8
kW
Useful efficiency
At rated heat output and high-temperature regime (*)
η4
88.2
88.3
88.1
%
At 30% of rated heat output and low-temperature re-
gime (**)
η1
98.9
98.9
98.6
%
Auxiliary electricity consumption
At full load
elmax
28.0
37.0
40.0
W
At part load
elmin
14.0
14.0
14.0
W
In Stand-by mode
PSB
3.0
3.0
3.0
W
Other parameters
Stand-by heat loss
Pstby
42.0
42.0
37.0
W
Pilot lame energy consumption
Pign
-
-
-
W
Annual energy consumption
QHE
37
42
52
GJ
Sound power level, indoors
LWA
51
53
-
dB
Emissions of nitrogen oxides
NOx
46
33
41
mg/kWh
For combination heaters
Declared load profile
XL
XL
XL
Water heating energy efficiency
ηwh
86
85
85
%
Daily electricity consumption
Qelec
0.127
0.167
0.148
kWh
Daily fuel consumption
Qfuel
22.777
22.921
23.093
kWh
Annual electricity consumption
AEC
28
37
32
kWh
Annual fuel consumption
AFC
17
17
17
GJ
(*)
High-temperature regime
means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
(**)
Low temperature
means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return
temperature (at heater inlet).
INSTALLER -
- SERVICE ENGINEER - PLEASE NOTE
USER
Conditional Warranty
This appliance is a sophisticated piece of equipment it is designed to give long term reliable service when
maintained as intended It may fail prematurely if it is not serviced. Service is a legal requirement in the EU
The NZ warranty on this appliance is conditional upon annual service being carried out. Where service is
not carried out the manufacture/distributor accepts no liability for any failure that could be associated to a
lack of maintenance.
Service invoice records must be made available when making a claim.
This includes but not exclusively Sensors electrodes heat exchangers and safety devices.
Note
servicing of this appliance should only be carried out by a competent engineer with detailed
knowledge and training – Commissioning and servicing Training is available in NZ through the distributors.
A schedule of service requirements is shown on page 28. Please note the requirement to replace the burner chamber
seal at each service
Labour allowances under the appliance warranty
is limited to the manufacturers schedule of time allowances
rounded up to the hour plus 1 hour for diagnosis, This is a fair representation of the time that an experienced
competent engineer would require to rectify a fault (Travel expensed are limited to the terms set out by the distributor)
(call out charges will only be covered in case of immediate danger to life or property)
Содержание EXCLUSIVE 25C
Страница 43: ......