38
EXCLUSIVE
DESCRIPTION
UM
EXCLUSIVE
25C
30C
35C
G20
G31
G20
G31
G20
G31
Gas pressure
Nominal natural gas pressure (G20) mbar
mbar
20
-
20
-
20
-
Nominal liquid gas LPG pressure (G31)
mbar
-
37
-
37
-
37
Hydraulic connections
CH input - output
Ø
3/4”
3/4”
3/4”
DHW input-output
Ø
1/2”
1/2”
1/2”
Gas input
Ø
3/4”
3/4”
3/4”
Boiler dimensions
Height
mm
740
740
740
Width
mm
420
420
420
Depth
mm
275
275
350
Boiler weight
kg
35
37
38
Heating output
Air capacity
Nm
3
/h
21,496
21,926
23,322
8,221-
2,375
29,247
31,654
10,935-
1,973
28,969
30,831
10,866-
2,789
36,447
39,456
13,629-
2,205
37,228
39,555
13,946-
3,207
Flue gas capacity
Nm
3
/h
23,302
Mass flue gas low rate
(max-min)
g/s
8,044-
1,671
Domestic hot water capacity
Air capacity
Nm
3
/h
31,050
31,671
33,688
11,874-
2,375
36,558
39,568
13,669-
1,973
36,212
38,539
13,582-
2,789
42,035
45,506
15,718-
2,205
42,937
45,620
16,084-
3,207
Flue gas capacity
Nm
3
/h
33,658
Mass flue gas low rate
(max-min)
g/s
11,619-
1,671
Fan performance
Residual discharge head of concentric pipes 0.85 m
Pa
60
60
160
Residual discharge head of separate pipes 0.5 m
Pa
195
198
165
Residual discharge head of boiler without pipes
Pa
199
199
190
Concentric flue gas outlet pipes
Diameter
mm
60-100
60-100
60-100
Maximum length
m
10
10
8
Losses for a 45°/90° bend
m
1,3/1,6
1,3/1,6
1,3/1,6
Hole in wall (diameter)
mm
105
105
105
Concentric flue gas outlet pipes
Diameter
mm
80-125
80-125
80-125
Maximum length
m
25
25
20
Losses for a 45°/90° bend
m
1/1,5
1/1,5
1/1,5
Hole in wall (diameter)
mm
130
130
130
Twin flue gas outlet pipes
Diameter
mm
80
80
80
Maximum length
m
70 + 70
60 + 60
40 + 40
Losses for a 45°/90° bend
m
1/1,5
1/1,5
1/1,5
Nox
class 6
class 6
class 6
Emission values at maximum and minimum output (**)
G20
G31
G20
G31
G20
G31
Maximum
CO s.a. less than
p.p.m.
140
150
150
200
220
220
CO
2
(***
see below
)
%
9,2
10,2
9,0
10,3
9.0
10,0
NOx s.a. lower than
p.p.m.
40
60
30
40
40
30
T flue gases
°C
63
64
73
66
65
70
Minimum
CO s.a. less than
p.p.m.
10
15
10
30
20
40
CO
2
(***
see below
)
%
9,1
10,2
8,9
10,0
9.1
10,0
NOx s.a. lower than
p.p.m.
25
35
25
40
30
40
T flue gases
°C
60
60
62
56
62
55
(*) Average value between various hot water operation conditions.
(**) check performed with concentric pipe Ø 60-100, length 0.85 m. - water temperature 80-60°C.
(***)
CO
2
tolerance = + 0.6% - 1.0%.
The data indicated must not be used to certify the system; for certification, use the data indicated in the “System handbook” measured during first ignition.
Содержание EXCLUSIVE 25C
Страница 43: ......