37
ENGLISH
TECHNICAL DATA
DESCRIPTION
UM
EXCLUSIVE
25C
30C
35C
G20
G31
G20
G31
G20
G31
Heating
Rated heat input
kW
18,00
24,00
30,00
kcal/h
15.480
20.640
25.800
Nominal heat output (80°/60°)
kW
17,60
23,54
29,37
kcal/h
15.139
20.248
25.258
Nominal heat output (50°/30°)
kW
19,17
25,56
31,77
kcal/h
16.486
21.982
27.322
Reduced heat input
kW
3,70
5,20
4,30
6,00
4,90
6,90
kcal/h
3.182
4.472
3.698
5.160
4.214
5.934
Reduced heat output (80°/60°)
kW
3,61
5,03
4,19
5,86
4,74
6,76
kcal/h
3.102
4.324
3.606
5.036
4.075
5.815
Reduced heat output (50°/30°)
kW
3,99
5,50
4,58
6,40
5,26
6,97
kcal/h
3.430
4.731
3.935
5.506
4.526
5.993
Nominal Range Rated heat output (Qn)
kW
18,00
24,00
30,00
kcal/h
15.480
20.640
25.800
Minimum Range Rated heat output (Qm)
kW
6,70
5,20
4,30
6,00
4,90
6,90
kcal/h
5.762
4.472
3.698
5.160
4.214
5.934
DHW
Rated heat input
kW
26,00
30,00
34,60
kcal/h
22.360
25.800
29.756
Nominal heat output (*)
kW
26,00
30,00
34,60
kcal/h
22.360
25.800
29.756
Reduced heat input
kW
3,70
5,20
4,30
6,00
4,90
6,90
kcal/h
3.182
4.472
3.698
5.160
4.214
5.934
Reduced heat output (*)
kW
3,70
5,20
4,30
6,00
4,90
6,90
kcal/h
3.182
4.472
3.698
5.160
4.214
5.934
Useful efficiency Pn max - Pn min (80°/60°)
%
97,8 -
97,5
97,7 -
96,7
98,1 -
97,5
97,1 -
97,6
97,9 -
96,7
96,7 -
98,0
Combustion efficiency
%
98,0
98,2
98,1
Useful efficiency Pn max - Pn min (50°/30°)
%
106,5 -
107,8
103,9 -
105,8
106,5 -
106,4
104,5 -
106,7
105,9 -
107,4
103,2 -
101,0
Useful efficiency Pn max 30% (30° return)
%
109,8
105,8
109,7
107,3
109,3
106,6
Efficiency at average P Range Rated (80°/60°)
%
98,0
98,1
97,8
Efficiency at average P Range Rated 30% (30° return)
%
109,8
109,8
109,5
Overall electric output (maximum heating output)
W
66
77
81
Overall electric output (maximum DHW output)
W
98
101
106
Circulator electric power (1.000 l/h) (DHW)
W
51
51
51
Circulator electric power (1.000 l/h) (CH)
W
41
41
41
Category
II2H3P
II2H3P
II2H3P
Country of destination
(+)
(+)
(+)
Voltage supply
V-Hz
230-50
230-50
230-50
Protection level
IP
X5D
X5D
X5D
Stop loss
W
42
42
37
Losses at the flue with burner off - burner on
%
0,14 - 2,01
0,11 - 1,80
0,07 - 1,90
Heating operation
Pressure
bar
3
3
3
Minimum pressure for standard operation
bar
0,25-0,45
0,25-0,45
0,25-0,45
Maximum temperature
°C
90
90
90
Selection field of heating water temperature
°C
20/45 ÷ 40/80
20/45 ÷ 40/80
20/45 ÷ 40/80
Pump: maximum head available
mbar
326
326
326
for system capacity
l/h
1.000
1.000
1.000
Membrane expansion tank
l
8
8
10
Expansion tank pre-loading (heating)
bar
1
1
1
DHW operation
Maximum pressure
bar
6
6
6
Minimum pressure
bar
0,15
0,15
0,15
Quantity of hot water with Δt 25° C
l/min
14,9
17,2
19,8
with Δt 30° C
l/min
12,4
14,3
16,5
with Δt 35° C
l/min
10,6
12,3
14,2
DHW minimum capacity
l/min
2
2
2
Selection field of domestic H
2
O temperature
°C
37-60
37-60
37-60
Flow regulator
l/min
10
12
12
Содержание EXCLUSIVE 25C