29
ENGLISH
USER GUIDE
LED
6 CONTROL PANEL (REC10)
The REC10 control unit has the function of a machine interface, it
displays the system’s settings and allows the parameters to be
accessed.
It is also capable of providing multi-zone control and weekly room
thermostat functionality.
While a system may be equipped with multiple REC10 units, only
one serves as the machine’s interface (MASTER).
any other REC10 units used serve as a chronothermostat for
regulating the ambient temperatures of the zones with which they
are associated; in this use the screen of the REC10 shows the
environmental data of the zone in which it is located
The REC10 unit features a backlit liquid crystal display.
LED
Light signal indicating the operating status of the boiler. Can be red or green (see specific paragraph)
REC10
Boiler control panel
Key area
ok=
confirm
back= return to the previous screen
cancel selection
return to the main screen (press > 2 sec.)
up=
allows you to choose between the options PLANT-STATE-SET-INFO-MENU and to surf through the
submenus scrolling upwards
down= allows you to choose between the options PLANT-STATE-SET-INFO-MENU and to surf through the
submenus scrolling down
On the left and right sides are displayed the icons indicating the status of the system, their meaning is the following:
This icon indicates that the OFF operating status mode has been set. Each ignition request is ignored except for the anti-freeze function. The
pump anti-lock, 3-way valve and anti-freeze function remain active.
This icon indicates that WINTER mode has been selected (HEATING function enabled). If a heating request from the main zone is in progress,
the icon will be flashing.
This icon indicates that the circuit for domestic hot water production is enabled. When a domestic hot water request is in progress, the icon
flashes. The P at the top of the domestic hot water icon indicates that the boiler preheating function is enabled; the P when flashing indicates
that a preheating request is in progress.
When the “central heating programming timing” is enabled this icon indicates that the system heating (main zone) is in AUTOMATIC mode (the
management of the heating requests follows what has been set with the timer).
If the heating function is not enabled during the current time frame, the icon will be crossed out.
When the “central heating programming timing” is enabled this icon indicates that the system heating (main zone) is in MANUAL mode (the
management of the heating requests does not follow what has been set with the programming timing, but it is always active).
OFF
This icon indicates that the system (main zone) has been set to off (not active).
This icon indicates that the system is detecting the presence of a flame.
This icon indicates the presence of an anomaly, and is always flashing.
Note:
The temperature of the hot water probe is shown at the centre of the main screen. The value’s meaning is indicated at the bottom of the display.
Whenever a heating request is in progress, the value displayed at the centre of the screen refers to the system’s low sensor, with the relative indication.
The value expressed in bar refers to the system’s water pressure.
The top of the screen shows the current date and time,- as well as the outdoor temperature only if a weather compensator is applied.
Depending on the type of application, some of the functions described in this manual might not be available.
REC10
SET
HOT WATER TEMPERATURE
P
42
°C
INFO
STATE
1.3 bar
MENU
12:17
PLANT
FRI
18/05/2013
Содержание EXCLUSIVE 25C
Страница 43: ......