INSTALLATION
49
HYDRONIC UNIT B
49
Setpoint parameters
Par
.
Jbus
Sigla
Description
Field
Default
Unit
Control panel
CCN
Table
401
HEA
T_OCC_W
ATER_STP
Home heating setpoint (water)
20,0 - 60,0
45.0
1/10°C
RW
WA
T_STP
402
HEA
T_UNO_W
ATER_
OFFSE
Night heating of
fset (water)
=-10-0
0.0
1/10 K
RW
WA
T_STP
403
HEA
T_ECO_W
ATER_
OFFSE
Of
fset heating away (water)
=-10-0
-5.0
1/10 K
RW
WA
T_STP
404
DHW_ECO_STP
DHW setpoint ECO
45.0
1/10°C
405
DHW_ANTI_ LEGIONELLA_
DHW anti-legionella setpoint
50,0 - 60,0
60.0
1/10°C
RW
WA
T_STP
406
DHW_STP
Setpoint DHW
30,0 - 60,0
50.0
1/10°C
RW
WA
T_STP
407
CO
OL_O
CC_W
AT
ER_S
TP
Home cooling setpoint (water)
5,0 - 18,0
12.0
1/10°C
RW
WA
T_STP
408
COOL_UNO_W
ATER_
OFFSE
Night cooling of
fset (water)
0,0 - 10,0
0.0
1/10 K
RW
WA
T_STP
409
COOL_ECO_W
ATER_
OFFSE
Of
fset cooling away (water)
0,0 - 10,0
5.0
1/10 K
RW
WA
T_STP
410
HEA
T_HYSTERESIS
Heating hysteresis (water)
0,5 - 2,0
1.0
1/10 K
RW
WA
T_STP
411
COOL_HYSTERESIS
Cooling hysteresis (water)
0,5 - 2,0
2.0
1/10 K
RW
WA
T_STP
412
HEA
T_CUR
V_MAX_
STP_OF
Maximum heating curve setpoint of
fset
=-5-5
0.0
1/10 K
RW
WA
T_STP
413
COOL_CUR
V_MIN_
STP_OF
Minimum cooling curve setpoint of
fset
=-5-5
0.0
1/10 K
RW
WA
T_STP
421
HEA
T_OCC_AIR_STP
Home heating setpoint (air)
12,0 - 34,0
19.0
1/10°C
RW
AIR_STP
422
HEA
T_UNO_AIR_OFFSET
Night heating of
fset (air)
=-10-0
-2.0
1/10 K
RW
AIR_STP
423
HEA
T_ECO_AIR_OFFSET
Of
fset heating outside the home (air)
=-10-0
-4.0
1/10 K
RW
AIR_STP
424
COOL_OCC_AIR_STP
Home cooling setpoint (air)
20,0 - 38,0
26.0
1/10°C
RW
AIR_STP
425
COOL_UNO_AIR_
OFFSET
Night cooling of
fset (air)
0,0 - 10,0
2.0
1/10 K
RW
AIR_STP
426
COOL_ECO_AIR_
OFFSET
Of
fset cooling away from home (air)
0,0 - 10,0
4.0
1/10 K
RW
AIR_STP
427
HOME_ANTI_FREEZE_
STP
Home antifreeze setpoint
6,0 - 12,0
6.0
1/10°C
RW
AIR_STP
428
AIR_DEL
TA_STP
Air delta setpoint
0,2 - 1,0
0.5
1/10 K
RW
AIR_STP
429
IAT_RESET_F
ACT
OR
IAT
recovery factor
0,0 - 2,0
0.0
RW
AIR_STP
Содержание 20161618