background image

5

ENGLISH

1  WARNINGS AND SAFETY  

 

b

The boilers manufactured in our factories are checked even in 

the smallest details in order to protect users and installers against 

possible  injury.  After  working  on  the  product,  qualified  personnel 

must check the electrical wiring, in particular the stripped part of 

leads, which must not protrude from the terminal board and avoiding 

possible contact with live parts of the leads themselves.

 

b

This installer and user manual constitutes an integral part of the 

product: make sure they are always kept with the appliance, even 

if it is transferred to another owner or user, or moved to another 

heating system. In case of loss or damage, please contact your local 

Technical Assistance Service for a new copy

.

 

b

This boiler may only be installed and serviced by personnel qualified 

in accordance with current regulations.

 

b

The installer must instruct the user about the operation of the appli-

ance and about essential safety regulations.

 

b

This boiler must only be used for the application it was designed for. 

The manufacturer accepts no liability within or without the contract 

for any damage caused to people, animals and property due to in-

stallation, adjustment and maintenance errors or to improper use.

 

b

This appliance should not be operated by children younger than 8 

years, people with reduced physical, sensory or mental capacities, 

or inexperienced people who are not familiar with the product, unless 

they are given close supervision or instructions on how to use it sa-

fely and are made aware by a responsible person of the dangers its 

use might entail. Children must not play with the appliance. It is the 

user’s responsibility to clean and maintain the appliance. Children 

should never clean or maintain it unless they are given supervision.

 

b

After removing the packaging, make sure the content is in good con

-

dition and complete. Otherwise, contact the dealer from whom you 

purchased the appliance.

 

b

The safety valve outlet must be connected to a suitable collection 

and venting system. The manufacturer declines all liability for any 

damage caused due to any intervention carried out in the safety 

valve.

 

b

The seal of the condensate drainage connection line must be secure, 

and the line must be fully protected against the risk of freezing (e.g. 

by insulating it).

 

b

Check that the rain water drainage channel of the flue gases fitting 

and the relative connection pipe are free of obstructions.

 

b

Dispose of all the packaging materials in the suitable containers at 

the corresponding collection centres.

 

b

Dispose of waste by being careful not to harm human health and 

without employing procedures or methods which may damage the 

environment.

 

b

At the end of its life, the product should be not be disposed of as solid 

urban waste, but rather it should be handed over to a differentiated 

waste collection centre.

 

b

During installation, inform the user that:

 -

in the event of water leaks, the water supply must be shut off and 

the Technical Assistance Centre must be contacted immediately

 -periodically check that the operating pressure of the hydraulic 

system is comprised between 1 and 1.5 bar. If it is not, request 

the prompt intervention of the Technical Assistance Centre or else 

professionally qualified personnel

.

 

b

If the boiler is not used for a long period of time, it is recommended 

to perform the following operations:

 -

turn the main appliance switch and the main system switch to “off”

 -close the fuel and water valves for the heating and domestic hot 

water system

 -empty the heating and domestic hot water circuits if there is the 

risk of freezing

 

b

Boiler maintenance must be carried out at least once a year; this 

should be booked in advance with the Technical Assistance Centre 

to ensure the necessary safety standards.

  At the end of its life, the product should be not be disposed of as solid 

urban  waste,  but  rather  it  should  be  handed  over  to  a  differentiated 

waste collection centre.

For safety reasons, please remember that:

 

a

It is forbidden to touch the appliance while barefoot or if parts of your 

body are wet.

INSTALLATION MANUAL

EN

ENGLISH

 

a

It is forbidden to activate electric devices or appliances such as 

switches, household appliances and so on if you notice a smell of 

fuel or unburned fuel. In this case:

 -ventilate the room by opening the doors and windows;

 -c

lose the fuel shut-off device

;

 -

request the prompt intervention of the Technical Assistance Centre 

or else professionally qualified personnel

.

 

a

Any technical or cleaning operation is forbidden before disconnecting 

the appliance from the main power supply by turning the system’s 

main switch to “OFF” and the main switch of the boiler to “OFF”.

 

a

Do not modify the safety or adjustment devices without the 

manufacturer’s authorisation and precise instructions. 

 

a

It is prohibited to pull, detach or twist the electrical cables coming 

from the appliance even if it is disconnected from the mains power 

supply.

 

a

Avoid blocking or reducing the size of the air vent openings in the 

installation room.

 

a

Do  not  leave  flammable  containers  and  substances  in  the  room 

where the device is installed.

 

a

It is forbidden to disperse the packaging material in the environment 

and leave it within children’s reach as it may be a potential source 

of danger. It must be disposed in accordance with the present law.

 

a

The condensate drain outlet must be turned towards the drain outlet 

avoiding the formation of more siphons.

 

a

Never carry out any work on the gas valve.

 

a

Only for the user:

 Do not access the inside of the boiler. Any work on 

the boiler should be carried out by the Technical Assistance Centre or 

by professionally qualified personnel. 

DESCRIPTION

EXCLUSIVE 

boilers  have  a  new  ACC  (Activate  Combustion  Control) 

system.  This new control system, developed by Beretta, ensures 

functionality, efficiency and low emissions under any conditions. 

The ACC system uses an ionisation sensor immersed in the burner flame, 

whose information allows the control board to operate the gas valve that 

regulates the fuel.  This sophisticated control system provides the auto-

regulation of the combustion, so there is no need for an initial calibration. 

The ACC system is able to adapt the boiler to operate with different gas 

compositions,  different outlet pipes  lengths  and different  altitudes  (within 

the  specified  design  limits).

 

The ACC  system  can  also  perform  an  auto-

diagnostic operation that locks out the burner before the permitted upper 

emission limit is exceeded

.

EXCLUSIVE

 is a type C condensing wall-hung boiler to be used for heating 

and the production of domestic hot water: depending on the fume discharge 

accessory  used,  it  is  classified  in  categories  B23P;B53P;  C13,C13x; 

C33,C33x; C43,C43x; C53,C53x; C63,C63x; C83,C83x; C93,C93x

.

In 

B23P 

configuration  (when  installed  indoors),  the  appliance  cannot 

be installed in bedrooms, bathrooms, showers or where there are open 

fireplaces without a proper air flow. The room where the boiler is installed 

must have proper ventilation. Detailed requirements for the installation of 

the flue, the gas piping and for ventilating the room, can be found in UNI 

7129-7131. 

In configuration 

C

, the appliance can be installed in any type of room (there 

are no limitations due to ventilation conditions or room volume).

3  INSTALLATION

3.1  Cleaning the system and characteristics of the water

In the case of a new installation or replacement of the boiler, it is necessary 

to clean the heating system.  To ensure the device works well, top up 

the  additives  and/or  chemical  treatments  (e.g.  anti-freeze  liquids,  filming 

agents, etc.) and check the parameters in the table are within the values 

indicated.

PARAMETERS

UM

HEATING CIRCUIT 

WATER

FILLING WATER

pH value

7-8

-

Hardness

°F

-

<15

Appearance

-

clear

Fe

mg/kg

0,5

-

Cu

mg/kg

0,1

-

 

b

Before installation, wash all system piping carefully in order to remove 

any residues that may impair the operation of the appliance.

 

b

Under the safety valve, install a water collecting funnel with the corre-

sponding discharge in the event of leaks due to the overpressure of the 

heating system. The domestic hot water circuit does not need a safety 

valve, but make sure that the pressure of waterworks does not exceed 6 

bar. In case of doubts, install a pressure reducer.

Содержание 20125265

Страница 1: ...DE INSTALARE I UTILIZARE PL PODR CZNIK INSTALATORA I U YTKOWNIKA SR PRIRU NIK ZA INSTALATERE I KORISNIKE EN INSTALLER AND USER MANUAL ES MANUAL PARA EL INSTALADOR Y EL USUARIO PT MANUAL DO INSTALADOR...

Страница 2: ...destinada nicamente para el usuario Atenci n Este manual de instrucciones contiene datos e informaci n tanto para el usuario como para el instalador Espec ficamente tener en cuenta que el usuario para...

Страница 3: ...iune destinat de asemenea pentru utilizator Avertisment Prezentul manual de instruc iuni con ine date i informa ii destinate at t utilizatorului c t i instalatorului n mod specific re ine i c utilizat...

Страница 4: ...pripremu a a ZABRANJENO za radnje koje NE SMEJU da se obave Odeljak tako e za korisnika Upozorenje Ovaj priru nik sa uputstvima sadr i podatke i informacije koje su namenjene i korisniku i instalater...

Страница 5: ...h the appliance while barefoot or if parts of your body are wet INSTALLATION MANUAL EN ENGLISH a a It is forbidden to activate electric devices or appliances such as switches household appliances and...

Страница 6: ...the boiler leaving the gas tap turned off 4 Activate a heat request via the room thermostat or the remote control panel so that the 3 way valve goes into heating mode 5 Activate a request for DHW as...

Страница 7: ...relation to installation requirements b b As envisaged by current legislation the boiler is designed to take in and dispose of flue gas condensate and or meteoric water condensate deriving from the fl...

Страница 8: ...n already hydraulically and electrically connected circulator whose useful available performance is indicated in the graphs at page 252 The circulator comes set from the factory with a 6 metre dischar...

Страница 9: ...available settings will appear in a cyclic sequence If the button A is not pressed the last setting will be stored A Operating status display B Settings display C Settings A B C If the button A is pr...

Страница 10: ...hing This icon indicates that the circuit for domestic hot water production is enabled When a domestic hot water request is in progress the icon flashes The P at the top of the domestic hot water icon...

Страница 11: ...40 sec 0 sec 240 sec SERVICE Only mixing zones with ACTUATION BE16 55 C 0 C 100 C SERVICE Only BT zones with ACTUATION BE16 0min 0min 240min SERVICE Only BT zones with ACTUATION BE16 2min VALVE RUN 24...

Страница 12: ...If EXTERNAL PROBE connected request type TA and zone type AT 0 4 0 2 0 8 INSTALLER If EXTERNAL PROBE connected request type TA and zone type BT 2 0 0 1 5 0 INSTALLER If request type AMBIENT PROBE or R...

Страница 13: ...INSTALLER 8 C DELTA T OFF 30 C INSTALLER 4 C 4 C DELTA T ON INSTALLER 0 min 0 min 199 min INSTALLER 30 C 0 C INSTALLER 110 C COLL T PROT 180 C INSTALLER 110 C 80 C T MAX COLL INSTALLER 40 C T LOCK 95...

Страница 14: ...RVICE AUTO ON AUTO INSTALLER 60 C 20 C 60 C SERVICE 10 C 0 C 25 C SERVICE SERVICE INSTALLER DEACTIVATE F DEACTIVATE F ACTIVATE F INSTALLER INSTALLER INSTALLER SERVICE 20 C 15 C 30 C SERVICE 35 C 30 C...

Страница 15: ...13 ENTER TIME AND DATE TIME DATE USE THE ARROWS TO MODIFY Note it is possible to change the TIME DATE settings as well as LANGUAGE and the duration of the back lighting also later by entering the MENU...

Страница 16: ...he desired one with the up and down keys confirming the selection TIMER OFF CH 3MIN ANTI CYCLE FUNCTION RESET CH TIMERS This parameter allows you to reset the REDUCED HEATING MAXIMUM OUTPUT TIMING dur...

Страница 17: ...tpoint that is possible range 20 C 80 5 C default 80 5 C for high temperature systems range 20 C 45 C default 45 C for low temperature systems CHANGING NAME This parameter allows you to attribute a sp...

Страница 18: ...e on the geographical location and on the delivery temperature envisaged and therefore on the type of system It is carefully calculated by the installer on the basis of the following formula KT T outl...

Страница 19: ...ted REC10 normally displays the domestic hot water temperature unless there is a heating request in progress in which case the boiler s outlet temperature is displayed BOILER OFF SUMMER WINTER OFF HOT...

Страница 20: ...TECHNICAL select ACTIVATE FUNCTION with the up and down keys and confirm the selection to activate the function select DEACTIVATE FUNCTION with the up and down keys and confirm the selection to deact...

Страница 21: ...E FUNCTION COMBUSTION ANALYSIS INSTALLER Note the combustion analysis function can also be activated by pressing the SW1 key on the electronic board AKM01 this requires removing the plug C from the co...

Страница 22: ...mits to set that value by referring to the graphs below 800 1200 1600 2000 2400 2800 3200 3600 4000 4400 4800 5200 5600 6000 6400 6800 7200 7600 8000 8400 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 Giri...

Страница 23: ...n s maximum speed It is not possible to release the alarm before the end of the post purging unless the boiler s power supply is switched off E022 iono alarm ON E023 iono alarm ON E024 iono alarm ON E...

Страница 24: ...ostic system which based on the total number of hours in certain operating conditions can signal the need to clean the primary exchanger alarm code E091 Once the cleaning operation has been completed...

Страница 25: ...ting and domestic hot water system In this case the anti freeze and anti blocking systems are deactivated Drain the heating and domestic water system if there is any risk of freezing BOILER OFF SUMMER...

Страница 26: ...the boiler 5 21 Replacing the REC10 MASTER b b The system s configuration operations need to be carried out by professionally qualified personnel of the Technical Assistance Centre When replacing the...

Страница 27: ...lectrodes it is necessary to replace also the relative sealing gasket checking and cleaning the drainage pipes checking the external appearance of the boiler checking the ignition switch off and opera...

Страница 28: ...the icon will be flashing This icon indicates that the circuit for domestic hot water production is enabled When a domestic hot water request is in progress the icon flashes The P at the top of the do...

Страница 29: ...using the up and down keys and then pressing ok to confirm the selection Pressing back takes you back to the initial screen without making any selection BOILER STATE MAIN ZONE BOILER MAIN ZONE STATE 9...

Страница 30: ...OR DELETE SELECTION CONFIRM OR DELETE SELECTION SET CONFIRM CANCEL THE PARAMETER WILL BE CHANGED 10 2 Hot water Press the up and down keys to change the boiler s domestic hot water setpoint Press ok...

Страница 31: ...ight off is automatically activated when the time that has been set in parameter MENU SETTINGS BACKLIGHT elapsed without having pressed any buttons In the screen saver the current time is normally dis...

Страница 32: ...THE ARROWS TO MODIFY ENTER START TIME Press the up and down keys to increase or decrease by 30 minutes the end time and press ok to confirm the selection START MAIN THURSDAY 14 00 07 30 11 30 18 00 EN...

Страница 33: ...keys to display the descriptions of any other faults that may be present For fault E041 If the pressure drops below the safety threshold of 0 3 bar the boiler displays the fault code E041 WATER TRANS...

Страница 34: ...o fill the system flashing 0 5 sec on 0 5 off transitional E042 water pressure transducer fault ON definitive E060 domestic hot water probe fault flashing 0 5 sec on 0 5 off transitional E070 fault fl...

Страница 35: ...98 2 Useful efficiency Pn max Pn min 50 30 106 5 107 8 106 5 106 4 106 5 103 5 106 3 105 4 Useful efficiency Pn max 30 30 return 109 8 109 7 109 4 109 3 Efficiency at average P Range Rated 80 60 98 0...

Страница 36: ...flow rate max min g s 11 619 1 671 11 874 2 375 13 669 1 973 13 582 2 789 15 718 2 363 15 941 3 317 19 080 2 699 19 524 2 789 Fan performance Residual discharge head of concentric pipes 0 85 m Pa 60 6...

Страница 37: ...minimum gas capacity Sm h 0 45 kg h 0 47 DHW minimum gas capacity Sm h 0 45 kg h 0 47 Number of fan rotations with slow ignition rpm 5 500 5 500 Maximum number of heating fan rotations rpm 6 500 6 50...

Страница 38: ...minal 18 24 31 34 kW Seasonal space heating energy efficiency s 94 94 94 94 Useful heat output At rated heat output and high temperature regime P4 17 6 23 5 31 4 34 3 kW At 30 of rated heat output and...

Страница 39: ...hado como un residuo s lido urbano sino que se debe enviar a un centro de recogida selectiva Por su seguridad conviene recordar que a a Se proh be tocar el aparato si se tienen los pies descalzos o co...

Страница 40: ...una aislaci n apropiada b b En caso de instalaci n es ESENCIAL proporcionar el espacio necesario para la introducci n del instrumento para el control del an lisis de combusti n En la fig 6b se presen...

Страница 41: ...m 1 5 m Conducto conc ntrico 60 100 mm horizontal 10 m 10 m 6 m 5 m 1 3 m 1 6 m Conducto conc ntrico 60 100 mm vertical 11 m 11 m 7 m 6 m 1 3 m 1 6 m M xima longitud recta P rdida de carga 25C 30C 35...

Страница 42: ...i n Esta operaci n se debe realizar cuando el sistema est fr o realizando las siguientes operaciones abrir los tapones de la v lvula de purgado de aire autom tica inferior A dos o tres vueltas para pe...

Страница 43: ...e bloqueo de tecla se logra presionando el pulsador A por m s de 10 segundos Durante este paso todos los LED C par padear n por 1 segundo 3 12 6 Modificaci n del modo de funcionamiento En condiciones...

Страница 44: ...t en modo MANUAL la gesti n de las solicitudes de calor no sigue lo que se ha ajustado con la temporizaci n de la programaci n pero siempre est activa OFF Este icono indica que se ha ajustado el siste...

Страница 45: ...40 seg SERVICIO Solo zonas mezcladas con ACTUACI N BE16 55 C 0 C 100 C SERVICIO Solo zonas BT con ACTUACI N BE16 0 min 0 min 240 min SERVICIO Solo zonas BT con ACTUACI N BE16 2 min RECORRIDO DE V LVUL...

Страница 46: ...XTERNA est conectada solicitud tipo TA y zona tipo AT 0 4 0 2 0 8 INSTALADOR Si la SONDA EXTERNA est conectada solicitud tipo TA y zona tipo BT 2 0 0 1 5 0 INSTALADOR Si solicita el tipo SONDA DE AMBI...

Страница 47: ...R INSTALADOR 60 C 10 C 130 C INSTALADOR 8 C DELTA T OFF 30 C INSTALADOR 4 C 4 C DELTA T ON INSTALADOR 0 min 0 min 199 min INSTALADOR 30 C 0 C INSTALADOR 110 C T PROT COLECTOR 180 C INSTALADOR 110 C 80...

Страница 48: ...AUTO INSTALADOR 60 C 20 C 60 C SERVICIO 10 C 0 C 25 C SERVICIO SERVICIO INSTALADOR DESACTIVAR F DESACTIVAR F ACTIVAR F INSTALADOR INSTALADOR INSTALADOR SERVICIO 20 C 15 C 30 C SERVICIO 35 C 30 C 55 C...

Страница 49: ...IFY 18 11 2013 ESTABLECER HORA Y FECHA HORA Y FECHA UTILIZA LA FLECHA PARA MODIFICAR Nota es posible modificar los ajustes de HORA y FECHA as como el IDIOMA y la duraci n de la retroiluminaci n esta l...

Страница 50: ...dad del ventilador se limita al 75 de la potencia t rmica m xima que se ha ajustado y al APAGADO CALEFACCI N El ajuste de f brica para este par metro es FUNCI N NO ACTIVA seleccionar FUNCI N ACTIVA ut...

Страница 51: ...ente Programaci n horaria no habilitada 0 Cuando el contacto del termostato ambiente se cierra siempre se cumple la solicitud de calor sin ninguna limitaci n de franja horaria Programaci n horaria hab...

Страница 52: ...compensaci n m s cercana al valor obtenido Ejemplo si el valor obtenido del c lculo es 1 3 ste se halla entre la curva 1 y la curva 1 5 Elegir la curva m s cercana es decir 1 5 Los valores KT ajustabl...

Страница 53: ...calefacci n sin un sensor de temperatura externa conectado Cuando no hay un sensor de temperatura externa la caldera opera en un punto fijo el punto de ajuste de CALEFACCI N en este caso se puede ajus...

Страница 54: ...tivar la funci n seleccionar DESACTIVA FUNCI N con las teclas up y down y confirmar la selecci n para desactivar la funci n INSTALLER SCREED HEATING FUNZIONE GIORNALIERA DEACTIVATE FUNCTION ACTIVATE F...

Страница 55: ...CTION ACTIVA FUNCI N DESHOLLINADOR INSTALADOR Nota la funci n de deshollinador tambi n se puede activar presionando la tecla SW1 en la tarjeta electr nica AKM01 esto requiere retirar el tap n C de la...

Страница 56: ...ustar dicho valor consultando los gr ficos a continuaci n 800 1200 1600 2000 2400 2800 3200 3600 4000 4400 4800 5200 5600 6000 6400 6800 7200 7600 8000 8400 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 Gi...

Страница 57: ...tiene un fallo E040 se debe realizar una carga manual utilizando el grifo de llenado A hasta que la presi n se encuentre entre 1 y 1 5 bar Luego cerrar el grifo de llenado para asegur ndose de o r el...

Страница 58: ...durante 45 segundos a la m xima velocidad del ventilador No es posible liberar la alarma antes de la finalizaci n de la post ventilaci n salvo que se apague la alimentaci n de la caldera E022 alarma...

Страница 59: ...ia que se mantiene hasta que la temperatura del agua en env o alcanza los 35 C anticongelamiento del agua caliente sanitaria la funci n se inicia si la temperatura medida por la sonda NTC deACS cae po...

Страница 60: ...CI N INSTALACI N seleccionar FLUSOSTATO PLANT FLUX SWITCH FLUX METER PLANT PLANT FLUX SWITCH FLUX METER PLANT INSTALACI N FLUX METRO FLUSOSTATO Una vez finalizado el procedimiento guiado el REC10 most...

Страница 61: ...ma en apagado cerrar los grifos de gas y agua del sistema de agua caliente sanitaria y de calefacci n Para garantizar que se mantengan las caracter sticas de funcionalidad y eficiencia del producto y...

Страница 62: ...URA DE SANITARIO VIE LED Se alizaci n luminosa que indica el estado de funcionamiento de la caldera Puede ser rojo o verde v ase p rrafo espec fico REC10 Cuadro de control de la caldera rea clave ok c...

Страница 63: ...n se puede seleccionar para ajustar el estado de la caldera al elegir una de las siguientes opciones OFF S LO ACS CALEFACCI N Y ACS El estado destacado es el que est seleccionado actualmente Para sel...

Страница 64: ...ando el nivel de confort deseado dentro del rango 5 5 Luego se le solicita al usuario confirmar la configuraci n del punto de ajuste seleccionar CONFIRMA o ANULA utilizando las teclas up y down y conf...

Страница 65: ...to el sistema regresar a los Establecimientos cancelando las modificaciones que se realizaron 12 17 ENTER TIME AND DATE TIME DATE USE THE ARROWS TO MODIFY 18 11 2013 ESTABLECER HORA Y FECHA HORA Y FEC...

Страница 66: ...FLECHA PARA MODIFICAR 13 2 Modifica Esta funci n sirve para editar un intervalo de tiempo ya presente para el d a seleccionado Presionar ok para seleccionar la funci n despu s de haberlo destacado si...

Страница 67: ...UN FRI MAIN SELECT DAYS ON WHICH YOU WANT TO COPY SCHEDULE OF THURSDAY USE THE ARROWS TO MODIFY PRINCIPAL LUN MAR SAB MIE DOM JUE VIE UTILIZA LA FLECHA PARA MODIFICAR CONFIRMA SELECCIONA LOS D AS EN L...

Страница 68: ...ndido 0 5 apagado transitoria tarjeta caldera p rdida de comunicaci n ON transitoria BUS 485 p rdida de comunicaci n ON transitoria Cuando la caldera tiene un fallo E040 se debe realizar una carga man...

Страница 69: ...ROR MENSAJE DE ERROR LED ROJOS LED VERDES DESCRIPCI N DEL TIPO DE ALARMA E021 alarma ion ON Estas son alarmas temporales que si ocurren 6 veces en una hora se vuel ven definitivas la alarma E097 se vi...

Страница 70: ...98 2 Rendimiento til Pn m x Pn m n 50 30 106 5 107 8 106 5 106 4 106 5 103 5 106 3 105 4 Rendimiento til Pn m x 30 30 retorno 109 8 109 7 109 4 109 3 Eficiencia a Range Rated P promedio 80 60 98 0 98...

Страница 71: ...Tubos de salida conc ntricos del gas de descarga Di metro mm 60 100 60 100 60 100 60 100 Longitud m xima m 10 10 6 5 P rdidas por curva de 45 90 m 1 3 1 6 1 3 1 6 1 3 1 6 1 3 1 6 Orificio de paso por...

Страница 72: ...n Sm h 0 45 kg h 0 47 Caudal gas m nimo agua sanitaria Sm h 0 45 kg h 0 47 N mero de rev del ventilador con encendido lento r p m 5 500 5 500 N mero m ximo de rev del ventilador de calefacci n r p m 6...

Страница 73: ...A Potencia calor fica nominal Pnominal 18 24 31 34 kW Eficiencia energ tica estacional de calefacci n s 94 94 94 94 Potencia calor fica til A potencia calor fica nominal y r gimen de alta temperatura...

Страница 74: ...deve ser entregue a um centro de recolha diferenciada Para a sua seguran a conveniente recordar que a a proibido tocar o aparelho se estiver descal o ou com partes do corpo molhadas MANUAL DE INSTALA...

Страница 75: ...ala o ESSENCIAL fornecer o espa o necess rio para a introdu o do instrumento para a verifica o da an lise de combust o Na fig 6b exibido um desenho de amostra onde as dist ncias entre caldeira e gabin...

Страница 76: ...curva liga o na caldeira os terminais e jun es exce o da conduta coaxial 60 100 mm vertical cujo comprimento retil neo n o inclui as curvas b b A caldeira fornecida sem a sa da de g s de combust o kit...

Страница 77: ...ica A inferior com duas ou tr s voltas para permitir uma ventila o cont nua do ar deixe o buj o da v lvula A open certificar se de que a torneira de entrada de gua fria esteja aberta Abrir a torneira...

Страница 78: ...r feito ao pressionar o bot o A por mais de 10 segundos Durante esta etapa todos os LEDs C piscar o por 1 segundo 3 12 6 Altera o no modo de opera o Em condi es de opera o normal o circulador opera co...

Страница 79: ...ite escolher entre as op es PLANT STATE SET INFO MENU e navegar pelos submenus deslizando para cima down permite escolher entre as op es PLANT STATE SET INFO MENU e navegar pelos submenus deslizando p...

Страница 80: ...eg 240 seg SERVI O Somente zonas de mistura com ATUA O BE16 55 C 0 C 100 C SERVI O Somente zonas BT com ATUA O BE16 0 min 0 min 240 min SERVI O Somente zonas BT com ATUA O BE16 2 min EXECUTAR V LVULA...

Страница 81: ...ona AT 0 4 0 2 0 8 INSTALADOR Se a SONDA EXTERNA conectada solicitar tipo TA e tipo de zona BT 2 0 0 1 5 0 INSTALADOR Se tipo de solicita o SONDAAMBIENTE ou REC10 10 0 20 INSTALADOR Se tipo de solicit...

Страница 82: ...130 C INSTALADOR 8 C DELTA T OFF 30 C INSTALADOR 4 C 4 C DELTA T ON INSTALADOR 0 min 0 min 199 min INSTALADOR 30 C 0 C INSTALADOR 110 C COL T PROT 180 C INSTALADOR 110 C 80 C T M X RESF INSTALADOR 40...

Страница 83: ...O 10 C 0 C 25 C SERVI O SERVI O INSTALADOR DESATIVAR F DESATIVAR F ATIVAR F INSTALADOR INSTALADOR INSTALADOR SERVI O 20 C 15 C 30 C SERVI O 35 C 30 C 55 C SERVI O INSTALADOR MTN MTN GPL INSTALADOR A...

Страница 84: ...s de su o do ar estejam funcionando corretamente que sejam garantidas as condi es para as manuten es normais no caso em que a caldeira seja colocada dentro ou entre os m veis a estanquidade da instala...

Страница 85: ...vem com uma luz constante na parte superior em rela o ao cone da gua quente Durante a igni o do queimador ap s uma solicita o de preaquecimento o s mbolo P come a a piscar Para desativar a fun o de pr...

Страница 86: ...80 5 C para sistemas de alta temp alcance 20 C 45 C 45 C padr o para sistemas de baixa temp ALTERA O DO NOME Este par metro permite o atribuir um nome espec fico zona de aquecimento POR Estepar metrop...

Страница 87: ...os as varia es externas de temperatura ter o menos impacto do que as que est o mal isoladas em compara o A habilita o da TERMOREGOLA O ocorre da seguinte maneira acesse os par metros t cnicos conforme...

Страница 88: ...um pedido de aquecimento em curso caso em que a temperatura de sa da da caldeira exibida BOILER OFF SUMMER WINTER OFF VER O INVERNO CALDEIRA 5 4 Regula o da temperatura da gua de aquecimento sem um se...

Страница 89: ...de iniciar verifique se a caldeira realiza os procedimentos de inicializa o e o encerramento subsequente corretamente Verifique a opera o de gua quente dom stica abrindo uma torneira de gua quente no...

Страница 90: ...SE DA COMBUST O INSTALADOR Nota A fun o de an lise da combust o tamb m pode ser ativada pressionando a tecla SW1 na placa eletr nica AKM01 isso requer a remo o do buj o C da tampa do painel de instrum...

Страница 91: ...as necessidades do cliente IMPORTANTE A fun o de an lise da combust o est ativa por um limite de tempo de 15 minutos o queimador desliga se uma temperatura de sa da de 95 C for atingida Ele acender n...

Страница 92: ...press o esteja entre 1 e 1 5 bars Em seguida feche a torneira de enchimento certifique se de ouvir o clique mec nico A b b Se a press o cair frequentemente entre em contato com o Centro de Assist ncia...

Страница 93: ...or de press o de gua ON problema E060 sonda de gua quente dom stica com falha lampejante 0 5 seg on 0 5 off transi o E070 sensor de fluxo com falha sensor de fluxo de sobretempe ratura fluxo alarme do...

Страница 94: ...nima pot ncia que mantida at a temperatura da gua de descarga alcan a 35 C anticongelamento da gua quente dom stica a fun o come a se a temperatura medida pela sonda do tanque de armazenamento cai aba...

Страница 95: ...SWITCH FLUX METER PLANT PLANT FLUX SWITCH FLUX METER PLANT INSTALA O MEDIDOR DE FLUXO FLUXOSTATO Uma vez que o procedimento orientado tenha terminado o REC10 ir para a tela inicial Continue com a conf...

Страница 96: ...manuten o observe as instru es fornecidas no cap tulo 1ADVERT NCIAS E SEGURAN AS Isso normalmente significa as seguintes tarefas remo o da oxida o do queimador remo o de qualquer escama o dos comutado...

Страница 97: ...dica que o circuito para produ o de gua quente dom stica est habilitado Quando uma solicita o de gua quente dom stica est em andamento o cone pisca O P na parte superior do cone de gua quente dom stic...

Страница 98: ...DEIRA ZONA PRINCIPAL ESTADO 9 1 Caldeira Esta fun o pode ser selecionada para definir o status da caldeira escolhendo uma das seguintes op es APAGADO VER O INVERNO O status destacado o que est atualme...

Страница 99: ...rior Se a sele o for cancelada ou a tecla back for pressionada se retorna tela SET anterior SET THE PARAMETER WILL BE CHANGED CONFIRM OR DELETE SELECTION CONFIRM CANCEL CONFIRMA OU ANULA A OPERA O SET...

Страница 100: ...torno for 55 C EFICI NCIA TIMA se 25 C valor m dio da sonda de retorno 55 C 42 OPTIMUM EFFICIENCY C P OPTIMAL EFFICIENCY EFICI NCIA OTIMA 05 11 12 1 4 Programa o da hora Ao selecionar esta fun o somen...

Страница 101: ...SETAS PARA MODIFICAR Para confirmar que a opera o foi conclu da com sucesso a tela mostrar a tabela com o novo intervalo de tempo piscando Nesse ponto o usu rio pode selecionar um novo intervalo de te...

Страница 102: ...GUA PRIMIR OK PARA CARREGAR A INSTALA O por um per odo de transi o de 10 min durante o qual poss vel iniciar o procedimento de carregamento semiautom tico pressionando a tecla ok chave para preencher...

Страница 103: ...tor de press o de gua ON problema E060 sonda de gua quente dom stica com falha lampejante 0 5 seg on 0 5 off transi o E070 sensor de fluxo com falha sensor de fluxo de sobretemperatura fluxo alarme do...

Страница 104: ...7 8 98 0 97 8 Rendimento de combust o 98 0 98 2 98 3 98 2 Rendimento til Pn m x Pn m n 50 30 106 5 107 8 106 5 106 4 106 5 103 5 106 3 105 4 Rendimento til a 30 Pn m x 30 retorno 109 8 109 7 109 4 109...

Страница 105: ...rga de fumos conc ntricos Di metro mm 60 100 60 100 60 100 60 100 Comprimento m ximo m 10 10 6 5 Perda para a introdu o de uma curva 45 90 m 1 3 1 6 1 3 1 6 1 3 1 6 1 3 1 6 Furo de atravessamento pare...

Страница 106: ...aquecimento Sm h 0 45 kg h 0 47 Caudal g s sanit rio m nimo Sm h 0 45 kg h 0 47 N mero de rota es do ventilador com igni o lenta rpm 5 500 5 500 N mero m ximo das rota es do ventilador de aquecimento...

Страница 107: ...a do aquecimento de gua A A A A Pot ncia calor fica nominal Pnominal 18 24 31 34 kW Efici ncia energ tica do aquecimento ambiente sazonal s 94 94 94 94 Energia calor fica til pot ncia calor fica nomin...

Страница 108: ...a v rosi szil rd hullad kkal rtalmatlan tani hanem el kell sz ll tani egy szelekt v hullad kgy jt k zpontba A biztons gos haszn lat rdek ben tartsa szem el tt hogy a a Ne rjen a k sz l khez mez tl b...

Страница 109: ...iztos tani a sz ks ges helyet a m szer bevezet s hez az g selemz shez A 6b br n egy mintarajzot mutatunk be ahol a kaz n s a szekr ny r s k z tti t vols g 300 mm hossz s g szersz mmal volt kialak tva...

Страница 110: ...cs v gekkel s illeszt sekkel egy tt rtend Kiv telt k pez a koaxi lis vezet khez val 60 100 mm es f gg leges eset ben amelynek egyenes vonal hossza nem a hajlatokkal egy tt rtend b b A kaz nt a f stg...

Страница 111: ...t lt s nek Ezt a m veletet akkor kell elv gezni amikor a rendszer hideg az al bbi m veleteket elv gezve k t vagy h rom fordulatnyit tekerve nyissa ki az als automata l gtelen t szelep z r kupakj t A a...

Страница 112: ...r szbe A billenty z r funkci enged lyez s t letilt s t a gomb A t bb mint 10 m sodpercig t rt n megnyom s val rheti el Ebben a l p sben az sszes LED C villog 1 m sodpercig 3 12 6 Az zemm d megv ltozt...

Страница 113: ...zemm dban van a f t sig nyek kezel se nem k veti azt ami a programoz si id z t ssel be van ll tva de mindig akt v OFF Ez az ikon azt jelzi hogy a rendszer f z na off ra van ll tva nem akt v Ez az iko...

Страница 114: ...140 sec 0 sec 240 sec SZERV Z Csak olyan kever z n k ahol ACTUATION BE16 55 C 0 C 100 C SZERV Z Csak olyan BT z n k ahol ACTUATION BE16 0min 0min 240min SZERV Z Csak olyan BT z n k ahol ACTUATION BE16...

Страница 115: ...KEL csatlakoztatva van TA ig nyt pus s AT z nat pus 0 4 0 2 0 8 TELEP T Ha a K LS RZ KEL csatlakoztatva van TA ig nyt pus s BT z nat pus 2 0 0 1 5 0 TELEP T Ha az ig nyt pus K RNYEZETI SZONDA vagy REC...

Страница 116: ...0 C 10 C 130 C TELEP T 8 C DELTA T OFF 30 C TELEP T 4 C 4 C DELTA T ON TELEP T 0 min 0 min 199 min TELEP T 30 C 0 C TELEP T 110 C GY JT T PROT 180 C TELEP T 110 C 80 C T MAX GY JT TELEP T 40 C T LOCK...

Страница 117: ...AUTO TELEP T 60 C 20 C 60 C SZERV Z 10 C 0 C 25 C SZERV Z SZERV Z TELEP T F DEAKTIV L SA F DEAKTIV L SA F AKTIV L SA TELEP T TELEP T TELEP T SZERV Z 20 C 15 C 30 C SZERV Z 35 C 30 C 55 C SZERV Z TELE...

Страница 118: ...E THE ARROWS TO MODIFY 18 11 2013 ID S D TUM BEVITEL ID D TUM HASZN LJA A NYILAKAT A M DOS T SHOZ Megjegyz s lehet s g van a ID D TUM be ll t sok valamint a NYELV s a h tt rvil g t s id tartam nak meg...

Страница 119: ...okkal a kijel l st meger s tve TIMER OFF CH 3MIN F T S ID Z T KI F T S ID Z T RESET Ez a param ter lehet v teszi a REDUK LT F T S MAXIMUM KIMENETI ID Z T SE alaphelyzetbe ll t s t amelynek sor n a ven...

Страница 120: ...ket 20 C 80 5 C tartom ny alap rtelmezett 80 5 C magas h m rs klet rendszerekhez 20 C 45 C tartom ny alap rtelmezett 45 C alacsony h m rs klet rendszerekhez N V MEGV LTOZTAT SA Ezzel a param terrel eg...

Страница 121: ...im lis k ls h m rs kletnek s ez ltal a f ldrajzi helynek valamint a tervezett el remen h m rs kletnek s ez ltal a rendszer t pus nak a f ggv nye Ezt a telep t st v gz szem lynek kell kell gondoss ggal...

Страница 122: ...lasztva az LLAPOT men ben majd a KAZ N t a hagyom nyos csak haszn lati meleg v z funkci be van kapcsolva A REC10 ltal ban a kaz n ltal szolg ltatott haszn lati meleg v z h m rs klet t mutatja BOILER O...

Страница 123: ...rendszer eset n a kaz n hossz f t s funkci val rendelkezik amely a k vetkez m don aktiv lhat ll tsa a kaz n llapot t OFF ll sba BOILER OFF SUMMER WINTER KIBOCS T S V GE NY R T L KAZ N l pjen be a m s...

Страница 124: ...rva v lassza ki az K M NYSEPR t a fel s le gombokkal a kijel l st meger s tve THERMOREGULATION PARAMETERS RANGE RATED CALIBRATION SWEEPER INSTAL TECHNICAL KALIBR L S RANGE RATED ID J R SK VET S PARAM...

Страница 125: ...l t sok sor n a megadott rt khez igazodjon b b A kalibr l s nem vonja mag val a kaz n begy jt s t A kaz n a g zt bl zatban felt ntetett gy ri be ll t sokkal van lesz ll tva Mindazon ltal a rendszerk v...

Страница 126: ...nyom s emelkedni kezd Amikor a felt lt s befejez d tt a g rd t zenet F LAUTOMATIKUS T LT S V GET RT felirat jelenik meg az oldal l b n l s a z ld s v r s LED ek k r lbel l 4 m sodpercig r gz tettek Am...

Страница 127: ...dszert villog 0 5 sec on 0 5 off tmeneti E042 v znyom s transzduktor hiba ON v gleges E060 a haszn lati meleg v z rz kel hib ja villog 0 5 sec on 0 5 off tmeneti E070 raml s rz kel hiba raml s rz kel...

Страница 128: ...tben h ig ny keletezik az g begyullad s minim lis kibocs t son addig g am g a kimen v z h m rs klete el nem ri az 35 C ot fagymentes t haszn lati meleg v z ez a funkci akkor indul el ha a HMV NTC szon...

Страница 129: ...nem k rnyezeti szab lyoz k nt K RNYEZ ha a REC10 rendszerinterf szk nt m k dik s a z na k rnyezeti szab lyoz jak nt is ahol telep tve van ON BOARD AMBIENT WHERE IS THE REC10 INSTALLED BOILER RAJTA VAN...

Страница 130: ...C B EXCLUSIVE 35C F EXCLUSIVE 42C E V lassza ki az G S KIKAPCS et Sz ks gess v lhat hogy ezt a param tert karbantart s eset n az AKM k rtya helyett az rz kel elektr d n vagy az g n programozza be abba...

Страница 131: ...s rz kel fontos funkci ja a kaz n gy jt si f zis ban s a megfelel g s karbantart s ban ebben az sszef gg sben a csere eset n mindig gondoskodnia kell arr l hogy helyesen legyen elhelyezve s szigor an...

Страница 132: ...atva ez az ikon jelzi hogy a f t rendszer f z na AUTOMATIKUS zemm dban van a f t sig nyek kezel se k veti azt ami az id kapcsol val be van ll tva Ha a f t si funkci nincs beiktatva a jelenlegi id kere...

Страница 133: ...laszthat ahhoz hogy be ll tsa a kaz n llapot t az al bbi lehet s gek egyik t kiv lasztva KIBOCS T S V GE OFF NY R T L A kiemelt st tusz az ppen kijel lt llapot Egy m sik llapot kiv laszt s hoz jel lje...

Страница 134: ...l s er s tse meg a kijel l st az ok kal A kiv laszt s meger s t se ut n a kijelz visszat r az el z BE LL T S k perny oldalra Ha a kiv laszt st t r lt k vagy a vissza gombot megnyomta visszat r az BE L...

Страница 135: ...HAT SFOK ha 25 C a visszat r szonda tlagos rt ke 55 C 05 11 42 OPTIMUM EFFICIENCY C P OPTIMAL EFFICIENCY OPTIM LIS HAT SFOK 12 1 4 Id program Ha ezt a funkci t v lasztja csak akkor ha az id beoszt s e...

Страница 136: ...30 22 30 USE THE ARROWS TO MODIFY ENTER END TIME START V GE F CS T RT K ENTER BEFEJEZ S IDEJE HASZN LJA A NYILAKAT A M DOS T SHOZ A m velet sikeres lez r s nak meger s t s hez a kijelz megmutatja a t...

Страница 137: ...O SET PLANT HOT WATER TEMPERATURE STATE MENU MEN LLAPOT LL T INF K ZPONT MELEG V Z RZ KEL P N E041 rendelleness ghez Ha a nyom s a 0 3 bar biztons gi k sz b al esik akkor a kaz n a 10 perc tmeneti id...

Страница 138: ...cre a ventil tor maxim lis sebess g n Nem lehet feloldani a riaszt st az ut l gtelen t s v ge el tt kiv ve ha a kaz n ramell t sa ki van kapcsolva E022 ion riaszt s ON E023 ion riaszt s ON E024 ion ri...

Страница 139: ...30 106 5 107 8 106 5 106 4 106 5 103 5 106 3 105 4 Hat konys g Pn max 30 visszat r 30 109 8 109 7 109 4 109 3 Hat sfok tlagos P Range Rated mellett 80 60 98 0 98 1 98 0 98 0 Hat sfok tlagos P Range R...

Страница 140: ...ztes g egy 45 90 k ny k beiktat sa miatt m 1 3 1 6 1 3 1 6 1 3 1 6 1 3 1 6 Falon thalad lyuk tm r mm 105 105 105 105 Koncentrikus f stg z kivezet cs vek tm r mm 80 125 80 125 80 125 80 125 Max hossz s...

Страница 141: ...45 kg h 0 47 HMV minim lis g zmennyis ge Sm h 0 45 kg h 0 47 Ventil tor fordulatsz ma lass gy jt ssal ford perc 5 500 5 500 F t ventil tor maxim lis fordulatsz ma ford perc 6 500 6 500 HMV ventil tor...

Страница 142: ...kleten 4 88 2 88 3 88 2 88 2 A m rt h teljes tm ny 30 n s alacsony h m rs kleten 1 98 9 98 9 98 6 98 5 Seg d ramk r k elektromos fogyaszt sa Teljes terhel s mellett elmax 28 0 37 0 31 4 34 3 W R szter...

Страница 143: ...are De eurile trebuie s fie eliminate f r riscuri pentru s n tatea uman i f r a recurge la proceduri sau la metode care ar putea cauza daune de mediu Pentru siguran a dumneavoastr trebuie s re ine i c...

Страница 144: ...trumentului pentru verificarea analizei arderii n fig 6b este prezentat un exemplu de desen n care distan ele dintre centrala termic i camer ni au fost ob inute folosind un instrument cu lungimea de 3...

Страница 145: ...vi separate 80 mm 70 70 m 50 50 m 30 30 m 27 27 m 1 m 1 5 m b b Lungimea n linie dreapt include i primul cot conectare n central borne i racorduri except nd conducta coaxial de 60 100 mm pe vertical a...

Страница 146: ...a inferioar cu dou sau trei rota ii pentru a permite o aerisire continu a aerului l sa i bu onul supapei A deschis asigura i v c robinetul de intrare ap rece este deschis deschide i robinetul de umple...

Страница 147: ...pompei de circula ie Activarea dezactivarea func iei de blocare a tastelor se realizeaz prin ap sarea timp de mai mult de 10 secunde a butonului A n timpul acestui pas toate LED urile C vor clipi tim...

Страница 148: ...e te indic faptul c este n desf urare o solicitare de pre nc lzire Atunci c nd este activat programarea orar a nc lzirii centrale aceast pictogram indic faptul c nc lzirea sistemului zona principal es...

Страница 149: ...240 sec SERVICE Numai zone de amestec cu AC IONARE BE16 140 sec 0 sec 240 sec SERVICE Numai zone de amestec cu AC IONARE BE16 55 C 0 C 100 C SERVICE Numai zone BT cu AC IONARE BE16 0 min 0 min 240 min...

Страница 150: ...TA i tip zon AT 0 4 0 2 0 8 N ATEN IA INSTALATORULUI Dac SONDA EXTERN este conectat tip solicitare TA i tip zon BT 2 0 0 1 5 0 N ATEN IA INSTALATORULUI Dac tipul de solicitare este SOND AMBIENTAL sau...

Страница 151: ...IA INSTALATORULUI 60 C 10 C 130 C N ATEN IA INSTALATORULUI 8 C DELTA T OPRIT 30 C N ATEN IA INSTALATORULUI 4 C 4 C DELTA T PORNIT N ATEN IA INSTALATORULUI 0 min 0 min 199 min N ATEN IA INSTALATORULUI...

Страница 152: ...STALATORULUI 60 C 20 C 60 C SERVICE 10 C 0 C 25 C SERVICE SERVICE N ATEN IA INSTALATORULUI DEZACTIVARE F DEZACTIVARE F ACTIVARE F N ATEN IA INSTALATORULUI N ATEN IA INSTALATORULUI N ATEN IA INSTALATOR...

Страница 153: ...TO MODIFY 18 11 2013 INTRODUCETI ORA SI DATA TIMP DATA UTILIZATI SAGETILE PENTRU MODIFICARE Not este posibil s modifica i set rile OR i DAT precum i LIMBA i durata ilumin rii din spate mai t rziu int...

Страница 154: ...area TIMER OFF CH 3MIN OPRIRE INCALZIRE RESET CRONO NC LZIRE Acest parametru v permite s reseta i TEMPORIZAREA PUTERII MAXIME DE NC LZIRE REDUS n timpul c reia tura ia ventilatorului este limitat la 7...

Страница 155: ...jutorul unui termostat de camer Programul orar nu este activat 0 C nd contactul termostatului de camer se nchide solicitarea de nc lzire este ntotdeauna ndeplinit f r nici o limitare a intervalului de...

Страница 156: ...easta se g se te ntre curba 1 i curba 1 5 n acest caz alege i curba cea mai apropiat respectiv 1 5 Valorile KT setabile sunt dup cum urmeaz sistem standard 1 0 3 0 sistem n pardoseal 0 2 0 8 Folosind...

Страница 157: ...ALA 5 4 Reglarea temperaturii apei de nc lzire cu un senzor conectat de temperatur exterioar C nd nu exist senzor de temperatur exterioar centrala termic func ioneaz la un punct fix punctul de setare...

Страница 158: ...VATI FUNC IA cu tastele sus i jos i confirma i selectarea pentru a activa func ia selecta i DEZACTIVATI FUNC IAcu tastele sus i jos i confirma i selectarea pentru a dezactiva func ia INSTALLER SCREED...

Страница 159: ...ACTIVATI FUNCTIA FUNCTIA COSAR INSTALATOR Not func ia co ar poate fi activat i prin ap sarea tastei SW1 de pe placa electronic AKM01 acest lucru necesit scoaterea fi ei C de pe capacul panoului de ins...

Страница 160: ...nale privind limitele emisiilor de gaze de ardere s se seteze aceast valoare prin trimiterea la graficele de mai jos 800 1200 1600 2000 2400 2800 3200 3600 4000 4400 4800 5200 5600 6000 6400 6800 7200...

Страница 161: ...unci c nd centrala termic are defec iunea E040 nc rcarea manual trebuie efectuat cu ajutorul robinetului de umplere A p n c nd presiunea este ntre 1 i 1 5 bari Apoi nchide i robinetul de umplere i asi...

Страница 162: ...itent 0 5 sec pornit 0 5 oprit tranzi ie E042 Defec iune traductor de presiune ap PORNIT anomalie E060 defec iune sond ap cald menajer intermitent 0 5 sec pornit 0 5 oprit tranzi ie E070 defec iune se...

Страница 163: ...LER CALIBRATION RANGE RATED SWEEPER EXHAUST PROBE RESET ALARM HISTORY RESETARE S GAZE ARSE FUNCTIA COSAR CALIBRARE RANGE RATED ISTORIC ALARME TEHNIC INSTALATOR parcurge i istoricul de alarme cu tastel...

Страница 164: ...FLUX SWITCH FLUX METER PLANT PLANT FLUX SWITCH FLUX METER PLANT CENTRALA DEBITMETRU FLUXOSTAT Odat ce procedura ghidat s a terminat REC10 va merge la ecranul ini ial Continua i cu configurarea dup cum...

Страница 165: ...ate de timp C nd efectua i opera ii de ntre inere respecta i instruc iunile date n capitolul 1 AVERTISMENTE I M SURI DE SIGURAN Aceasta presupune de obicei efectuarea urm toarelor sarcini eliminarea o...

Страница 166: ...mitent Aceast pictogram indic faptul c circuitul pentru producerea de ap cald menajer este activat C nd o solicitare de ap cald menajer este n des f urare pictograma clipe te P n partea superioar a pi...

Страница 167: ...ZONA PRINCIPALA STARE 9 1 Central Aceast func ie poate fi selectat pentru a seta starea centralei termice aleg nd una dintre urm toarele op iuni STINS VAR IARN Starea eviden iat este cea care este sel...

Страница 168: ...sat reveni i la ecranul SET SET THE PARAMETER WILL BE CHANGED CONFIRM OR DELETE SELECTION CONFIRM CANCEL CONFIRMATI SAU STERGETI SELECTIA SET CONFIRM ANULATI PARAMETRUL VA FI MODIFICAT 10 3 Pre nc lzi...

Страница 169: ...ste activat POR 1 este posibil s modifica i urm toarele PRINCIPAL ZONA 1 ZONA 2 Pentru a avea acces la programul temporizator dorit este necesar s l eviden ia i folosind tastele sus i jos i apoi ap sa...

Страница 170: ...poate selecta un nou interval de timp pentru a fi modificat sau poate ap sa napoi pentru a reveni la ecranul anterior PROGRAM ORAR START MAIN THURSDAY SELECT PERIOD TO MODIFY 07 30 07 30 11 30 18 00 E...

Страница 171: ...ru un timp de tranzi ie de 10 min n timpul c ruia este posibil pornirea procedurii de nc rcare semiautomat ap s nd tasta ok pentru a umple sistemul procedura poate fi pornit numai n modul VAR sau IARN...

Страница 172: ...nit 0 5 oprit tranzi ie E042 Defec iune traductor de presiune ap PORNIT anomalie E060 defec iune sond ap cald menajer intermitent 0 5 sec pornit 0 5 oprit tranzi ie E070 defec iune senzor pe tur supra...

Страница 173: ...8 97 5 98 1 97 5 98 1 97 8 98 0 97 8 Randament la ardere 98 0 98 2 98 3 98 2 Eficien util Pn max Pn min 50 30 106 5 107 8 106 5 106 4 106 5 103 5 106 3 105 4 Eficien util la 30 Pn max 30 retur 109 8...

Страница 174: ...669 1 973 13 582 2 789 15 718 2 363 15 941 3 317 19 080 2 699 19 524 2 789 Performan e ventilator Presiune de evacuare rezidual evi concentrice 0 85 m Pa 60 60 160 150 Presiune de evacuare rezidual ev...

Страница 175: ...rota ii ventilator pentru nc lzire rpm 6 500 6 500 Num r maxim de rota ii ventilator pentru ACM rpm 7 900 7 900 Num r minim de rota ii ventilator pentru nc lzire rpm 1 500 2 000 Num r minim de rota i...

Страница 176: ...3 5 31 4 34 3 kW La 30 din puterea termic nominal i regim de temperatur sc zut P1 5 9 7 9 10 5 11 5 kW Randament util La puterea termic nominal i regim de temperatur ridicat 4 88 2 88 3 88 2 88 2 La 3...

Страница 177: ...rdy bezpiecze stwa Po zako czeniu eksploatacji urz dzenie nie mo e zosta zutylizowane jako odpad komunalny ale nale y je przekaza do punktu selektywnej zbi rki odpad w INSTRUKCJA MONTA U URZ DZENIA PL...

Страница 178: ...ych atwo nagrzewaj ce si ciany np drewniane musz by pokryte w a ciw izolacj ochronn b b Podczas monta u KONIECZNE jest pozostawienie przestrzeni wystarczaj cej do umieszczenia w niej analizatora spali...

Страница 179: ...m 1 5 m Przew d podw jny 80 mm 70 70 m 50 50 m 30 30 m 27 27 m 1 m 1 5 m b b Do d ugo ci w linii prostej zalicza si pierwsze kolano po czenie z kot em zako czenia i z cza Wyj tek stanowi pionowy przew...

Страница 180: ...i odkr ci ko paki dolnego A automatycznego zaworu odpowietrzaj cego obracaj c je dwa lub trzy razy pozostawi korek zaworu A otwarty umo liwiaj c ci g y przep yw powietrza upewni si e zaw r wlotowy zim...

Страница 181: ...ezaktywacja funkcji blokady przycisku nast puje po naci ni ciu przycisku A przez d u ej ni 10 sekund Podczas tej operacji wszystkie wska niki LED C za wiec na 1 sekund 3 12 6 Zmiana trybu pracy W norm...

Страница 182: ...y opcjami INSTALACJA STATUS USTAW INFO MENU i nawigacj mi dzy pod menu za pomoc przewijania w d Naciskaj c klawisze w g r i w d mo na wybra nast puj ce opcje INSTALACJA przewijany komunikat na wy wiet...

Страница 183: ...240 s SERWIS Tylko strefy mieszania z parametrem URUCHAMIANIE BE16 55 C 0 C 100 C SERWIS Tylko strefy BT z parametrem URUCHAMIANIE BE16 0 min 0 min 240 min SERWIS Tylko strefy BT z parametrem URUCHAM...

Страница 184: ...ZEWN TRZNY jest pod czony za daj typu TA i typu strefy AT 0 4 0 2 0 8 INSTALATOR Je eli CZUJNIK ZEWN TRZNY jest pod czony za daj typu TA i typu strefy BT 2 0 0 1 5 0 INSTALATOR Dla danego typu CZUJNI...

Страница 185: ...C 10 C 130 C INSTALATOR 8 C DELTA T WY 30 C INSTALATOR 4 C 4 C DELTA T W INSTALATOR 0 min 0 min 199 min INSTALATOR 30 C 0 C INSTALATOR 110 C T OCHR KOLEKT 180 C INSTALATOR 110 C 80 C T MAKS KOLEKT INS...

Страница 186: ...TO INSTALATOR 60 C 20 C 60 C SERWIS 10 C 0 C 25 C SERWIS SERWIS INSTALATOR DEZAKTYWUJ F DEZAKTYWUJ F AKTYWUJ F INSTALATOR INSTALATOR INSTALATOR SERWIS 20 C 15 C 30 C SERWIS 35 C 30 C 55 C SERWIS GAZ Z...

Страница 187: ...i gazowej s zgodne z danymi znajduj cymi si na tabliczce znamionowej urz dzenia czy przewody wylotowe spalin i dolotowe powietrza zasilaj cego pracuj poprawnie czy zosta y zagwarantowane warunki do p...

Страница 188: ...uje wysok temperatur wody w wymienniku ciep ej wody u ytkowej w celu skr cenia czasu oczekiwania po odkr ceniu kranu Po aktywacji funkcji podgrzewania przy ikonie ciep ej wody pojawia si symbol P wiec...

Страница 189: ...amyka si danie ciep a jest zawsze spe nione bez adnego ograniczenia przedzia u czasowego Harmonogram aktywny 1 Gdy styk termostatu pomieszczenia zamyka si danie ciep a zostaje aktywowane zgodnie z pro...

Страница 190: ...w nale y post powa jak ni ej przej do menu parametr w technicznych zgodnie z opisem w sekcji 4 1 Dost p do parametr w technicznych wybra kolejno REGULACJA POGODOWA i TYP BUDYNKU nie PROG POGODOWY za p...

Страница 191: ...nstalowany kocio pracuje na zadanej warto ci sta ej W takim wypadku nastawa OGRZEWANIE zostaje wybrana na ekranie g wnym panelu REC10 w zakresie od 40 C do 80 5 C dla system w wysokotemperaturowych lu...

Страница 192: ...C 4 0 35 C 5 0 35 C 6 0 30 C 7 0 25 C 5 11 Kontrole podczas i po pierwszym uruchomieniu Po uruchomieniu sprawdzi czy kocio przeprowadza wszystkie procedury rozruchowe i wy cza si prawid owo Sprawdzi d...

Страница 193: ...onanie wyboru SWEEPER INSTALLER ACTIVATE FUNCTION AKTYWUJ FUNKCJ KOMINIARZ INSTALATOR Uwaga funkcja kominiarz mo e by r wnie uruchomiona przez naci ni cie przycisku SW1 na panelu elektroniki AKM01 wym...

Страница 194: ...temperatury dla da ciep a zgodnie z potrzebami u ytkownika WA NE Funkcja kominiarz pozostaje aktywna przez 15 minut je eli zosta a osi gni ta temperatura wyj ciowa 95 C palnik wy cza si Zostaje on zap...

Страница 195: ...r czne nape nianie przy pomocy zaworu A do osi gni cia ci nienia 1 0 1 5 bara Przy zamykaniu zaworu nape niaj cego powinno wyst pi mechaniczne klikni cie A b b Je eli spadki ci nienia s zbyt cz ste na...

Страница 196: ...atora W ostateczny E040 przetwornik wodny za adowa system W ostateczny E041 przetwornik wodny nacisn OK aby nape ni system b yska 0 5 s w 0 5 s wy przej ciowy E042 usterka przetwornika ci nienia wody...

Страница 197: ...e maksimum 50 aby wy wietli histori alarm w przej do menu parametr w technicznych zgodnie z opisem w sekcji 4 1 Dost p do parametr w technicznych wybra HISTORIA ALARM W za pomoc przycisk w w g r i w d...

Страница 198: ...UX SWITCH FLUX METER PLANT INSTALACJA MIERNIK PRZEP YWU CZUJNIK PRZEP YWU Gdy wspomagana procedura zostaje zako czona panel REC10 powraca do ekranu pocz tkowego Kontynuowa konfiguracj jak nast puje pr...

Страница 199: ...zestrzega wskaz wek zawartych w rozdziale 1 OSTRZE ENIA I BEZPIECZE STWO Z regu y s to nast puj ce czynno ci usuni cie wszelkich zanieczyszcze palnika spowodowanych utlenianiem usuni cie kamienia z wy...

Страница 200: ...OGRZEWANIA w czona Je eli danie ciep a ze strefy g wnej jest w toku ikona b dzie pulsowa Ta ikona wskazuje e uk ad c w u jest w czony Je eli danie ciep a z uk adu c w u jest w toku ikona b dzie pulso...

Страница 201: ...AIN ZONE KOCIO G WNA STREFA STATUS 9 1 Kocio Ta funkcja mo e by u yta w celu wybrania stanu kot a spo r d nast puj cych opcji WY CZONY LATO TYLKO C W U C O I C W U Stan bie cy jest pod wietlony Aby wy...

Страница 202: ...anu USTAW SET THE PARAMETER WILL BE CHANGED CONFIRM OR DELETE SELECTION CONFIRM CANCEL POTWIERD ALBO USU WYB R USTAW ZATWIERD ANULUJ PARAMETR ZOSTANIE ZMIENIONY 10 3 Podgrzanie wst pne Funkcja ta podt...

Страница 203: ...u jest w przedziale 25 C 55 C 05 11 42 OPTIMUM EFFICIENCY C P OPTIMAL EFFICIENCY OPTYMALNA SPRAWNO 12 1 4 Harmonogram czasowy Po wybraniu tej funkcji tylko w przypadku gdy harmonogram jest aktywny czy...

Страница 204: ...twierdza dokonanie wyboru START MAIN THURSDAY 14 00 07 30 11 30 18 00 END 08 30 13 30 22 30 USE THE ARROWS TO MODIFY ENTER END TIME START KONIEC G WNY CZWARTEK WEJD GODZINA ZAKO CZENIA U YJ WSKA NIK W...

Страница 205: ...STATE MENU MENU STATUS USTAW INFO INSTALACJA TEMPERATURA C W U PT Dotyczy b du E041 Je eli ci nienie spadnie poni ej warto ci bezpiecznej 0 3 bara kocio wygeneruje kod b du E041 CZUJNIK WODYALARM WCI...

Страница 206: ...ylatora W ostateczny E040 przetwornik wodny za adowa system W ostateczny E041 przetwornik wodny nacisn OK aby nape ni system b yska 0 5 s w 0 5 s wy przej ciowy E042 usterka przetwornika ci nienia wod...

Страница 207: ...6 4 106 5 103 5 106 3 105 4 Sprawno u ytkowa Pn maks przy 30 30 powr t 109 8 109 7 109 4 109 3 Sprawno Range Rated przy redniej P 80 60 98 0 98 1 98 0 98 0 Sprawno Range Rated przy redniej P 30 30 pow...

Страница 208: ...ugo m 10 10 6 5 Straty na kolanku 45 90 m 1 3 1 6 1 3 1 6 1 3 1 6 1 3 1 6 Otw r w cianie rednica mm 105 105 105 105 Wsp osiowe przewody odprowadzenia spalin rednica mm 80 125 80 125 80 125 80 125 Mak...

Страница 209: ...a obrot w wentylatora c o obr min 6500 6500 Maksymalna pr dko obrotowa wentylatora c w u obr min 7900 7900 Minimalna liczba obrot w wentylatora c o obr min 1500 2000 Minimalna liczba obrot w wentylato...

Страница 210: ...zy znamionowej mocy cieplnej i w re imie wysokotemperaturowym P4 17 6 23 5 31 4 34 3 kW Przy znamionowej mocy cieplnej na poziomie 30 i w re imie niskotemperaturowym P1 5 9 7 9 10 5 11 5 kW Sprawno u...

Страница 211: ...U NIK ZA INSTALATERE SR SRPSKI zatvorite mehanizam za prekid dovoda goriva zatra ite hitnu intervenciju centra za tehni ku podr ku ili drugog profesionalno kvalifikovanog osoblja a a Zabranjena je sva...

Страница 212: ...kotla ostavljaju i zatvorenu slavinu za gas 4 Aktivirati zahtev za grejanje preko sobnog termostata ili komandne table za daljinsko upravljanje tako da se trokraki ventil namesti u poziciju za grejanj...

Страница 213: ...e odnose na pribor za dimne gasove koji je dostupan u katalogu b b Obavezno je kori enje odre enih cevi b b Neizolovane cevi za odvod dimnih gasova predstavljaju potencijalne izvore opasnosti b b Kori...

Страница 214: ...e tako da glavni prekida instalacije stavite u polo aj isklju eno Zatvorite ventile grejnog sistema Pove ite crevo na ispusni ventil sistema C Ru no otpu tajte ispusni ventil sistema C 3 11 Pra njenje...

Страница 215: ...em od 10 sekundi Tokom ovog koraka sve LED diode C trepere 1 sekundu 3 12 6 Promena re ima rada U normalnim uslovima rada cirkulaciona pumpa radi po fabri kim pode avanjima ili poslednjim postavljeni...

Страница 216: ...ikona treperi Ova ikona ozna ava da je omogu ena mre a za proizvodnju tople potro ne vode Kad je u toku zahtev za toplom potro nom vodom ikona treperi P na vrhu ikone za sanitarnu toplu vodu ozna ava...

Страница 217: ...40 s SERVISIRANJE Samo zone me anja gde je POKRETANJE BE16 55 C 0 C 100 C SERVISIRANJE Samo BT zone gde je POKRETANJE BE16 0 min 0 min 240 min SERVISIRANJE Samo BT zone gde je POKRETANJE BE16 2 min RA...

Страница 218: ...SONDApovezana 2 0 1 0 3 0 INSTALATER Ako je SPOLJA NJASONDApovezana vrsta zahteva TA i vrsta zone AT 0 4 0 2 0 8 INSTALATER Ako je SPOLJA NJASONDApovezana vrsta zahteva TA i vrsta zone BT 2 0 0 1 5 0...

Страница 219: ...DELTAT ISKLJ 30 C INSTALATER 4 C 4 C DELTAT UKLJ INSTALATER 0 min 0 min 199 min INSTALATER 30 C 0 C INSTALATER 110 C T ZA T KOLEK 180 C INSTALATER 110 C 80 C MAKS T KOLEK INSTALATER 40 C T ZAKLJ 95 C...

Страница 220: ...TER 60 C 20 C 60 C SERVISIRANJE 10 C 0 C 25 C SERVISIRANJE SERVISIRANJE INSTALATER DEAKTIVIRAJ F DEAKTIVIRAJ F AKTIVIRAJ F INSTALATER INSTALATER INSTALATER SERVISIRANJE 20 C 15 C 30 C SERVISIRANJE 35...

Страница 221: ...lno rade da je omogu eno redovno odr avanje ako se kotao nalazi unutar ili izme u delova name taja zaptivku sistema za dotok gasa da brzina protoka goriva odgovara vrednostima potrebnim za kotao da si...

Страница 222: ...ION ACTIVE INSTALLER FUNKCIJA NIJE AKTIVNA FUNKCIJA AKTIVNA ANUL VREME GREJANJA INSTALATER TERMOSTAT SANITARNE TOPLE VODE Ovaj parametar vam omogu ava da podesite vrstu TERMOSTATA SANITARNE TOPLE VODE...

Страница 223: ...DAY START MAIN THURSDAY END ZONE SCHEDULE PO ETAK KRAJ GLAVNI ETVRTAK PROGRAM ZONA ODABIR DAN 5 2 4 Pode avanje termoregulacije Termoregulacija radi samo kada je senzor spolja nje temperature povezan...

Страница 224: ...htev za grejanjem i kotao se pali na displeju se pojavljuje ikona Kotao e se pokrenuti i nastaviti sa radom dok ne dostigne pode enu temperaturu nakon ega se vra a u re im pripravnosti FUNKCIJA CIKLUS...

Страница 225: ...funkcija sanitarne tople vode kotla se aktivira Ova funkcija omogu ava da se odr i topla voda to omogu uje izmenjiva sanitarne vode i smanjuje vreme ekanja Kada je funkcija predzagrevanja omogu ena si...

Страница 226: ...1 0 20 C 6 22 C 12 24 C 18 26 C 2 0 28 C 12 30 C 3 0 32 C 4 0 35 C 5 0 35 C 6 0 30 C 7 0 25 C 5 11 Provere tokom i nakon prvog pu tanja u rad Nakon pokretanja proverite da li kotao pravilno obavlja po...

Страница 227: ...tabeli za vi e gasova NE OBAVLJAJTE NIKAKVO PODE AVANJE GASNOG VENTILA kontaktirajte centar za tehni ku pomo b b Gasni ventil NE ZAHTEVA PODE AVANJA i eventualne manipulacije dovode do neispravnosti i...

Страница 228: ...jeni odgovaraju i radni uslovi Postoji maksimum od 3 uzastopna poku aja pri osloba anju REC10 koji kada se potro e mogu e je odblokirati kotao isklju ivanjem i ponovnim povezivanjem na elektri no napa...

Страница 229: ...i avanja osim ako se isklju i napajanje kotla E094 nepotpuno sagorevanje UKLJU ENO E095 nepotpuno sagorevanje UKLJU ENO E058 kvar glavnog napona UKLJU ENO Ovo su privremeni kvarovi koji ograni avaju...

Страница 230: ...kcija se pokre e ako temperatura koju meri NTC sonda sanitarne tople vode padne ispod 5 C U toj fazi nastaje toplotni zahtev sa paljenjem gorionika sa minimalnom snagom koja se odr ava sve dok izlazna...

Страница 231: ...akon zamene REC10 pre nego nakon RESET SISTEMA daljinska kontrola prikazuje po etni ekran sa revizijom firmvera Pritiskom na ok pokre e se vo eni postupak za konfigurisanje sistema izaberite eljene op...

Страница 232: ...dataka na AKM01 i onih u REC10 U tom slu aju potonji e postaviti pitanje korisniku koju od dve konfiguracije treba smatrati va e om biranjem vra anja konfiguracije sa samog REC10 mogu e je izbe i pono...

Страница 233: ...vanja radi obezbe ivanja pravilnog rada b b U slu aju kada nakon zamene elektronske plo e ili odr avanja elektrode za detekciju ili gorionika analiza sagorevanja vra a tolerantne vrednosti mo e biti p...

Страница 234: ...okade pumpe trosmerni ventil i funkcija protiv smrzavanja ostaju aktivni Ova ikona ozna ava da je izabran re im ZIMA funkcija GREJANJA omogu ena Ako je zahtev za grejanje iz glavne zone u toku ikona t...

Страница 235: ...a a na po etni ekran bez vr enja ikakvog izbora BOILER STATE MAIN ZONE KOTAO GLAVNA ZONA STANJE 9 1 Kotao Ova funkcija se mo e izabrati kako bi se podesio status kotla biranjem jedne od slede ih opcij...

Страница 236: ...back vra ate se na ekran SET SET THE PARAMETER WILL BE CHANGED CONFIRM OR DELETE SELECTION CONFIRM CANCEL POTVDI ILI PONI TI OPRACIJU SET POTVRDI PONI TI PARAMETAR BI E IZMENJENO 10 3 Predgrevanje Ova...

Страница 237: ...4 Vremensko planiranje Izborom ove funkcije samo ako je omogu en vremenski raspored POR 1 je mogu e promeniti slede e GLAVNI ZONA 1 ZONA 2 Da biste pristupili eljenom programu tajmera potrebno je obel...

Страница 238: ...bere novi vremenski okvir za izmenu ili da pritisne back da bi se vratio na prethodni ekran VREMENSKI PROGRAM START MAIN THURSDAY SELECT PERIOD TO MODIFY 07 30 07 30 11 30 18 00 END 08 30 14 00 22 30...

Страница 239: ...ikazuje kod kvara E041 TRANSDUKTOR VODE PRITISNUTI OK ZA DOPUNITI SISTEM u prelaznom roku od 10 min tokom kog je mogu e pokrenuti proceduru poluautomatskog punjenja pritiskom tastera ok za punjenje si...

Страница 240: ...ra Nije mogu e otpustiti alarm pre zavr etka postventilacije osim ako se ne isklju i napajanje kotla E094 nepotpuno sagorevanje UKLJU ENO E095 nepotpuno sagorevanje UKLJU ENO E058 kvar glavnog napona...

Страница 241: ...st Pn max Pn min 80 60 97 8 97 5 98 1 97 5 98 1 97 8 98 0 97 8 Efikasnost sagorevanja 98 0 98 2 98 3 98 2 Iskori enost Pn max Pn min 50 30 106 5 107 8 106 5 106 4 106 5 103 5 106 3 105 4 Korisni u ina...

Страница 242: ...199 199 195 190 Koncentri ne cevi za odvod dimnih gasova Pre nik mm 60 100 60 100 60 100 60 100 Maksimalna du ina m 10 10 6 5 Gubitak pri ubacivanju cevi od 45 90 m 1 3 1 6 1 3 1 6 1 3 1 6 1 3 1 6 Otv...

Страница 243: ...e obr min 6 500 6 500 Maksimalni broj obrtaja ventilatora za sanitarnu toplu vodu obr min 7 900 7 900 Minimalni broj obrtaja ventilatora za grejanje obr min 1 500 2 000 Minimalni broj obrtaja ventilat...

Страница 244: ...P4 17 6 23 5 31 4 34 3 kW Pri 30 nazivne toplotne snage i niskotemperaturnom re imu P1 5 9 7 9 10 5 11 5 kW Iskoristivost Pri nazivnoj toplotnoj snazi i visokotemperaturnom re imu 4 88 2 88 3 88 2 88...

Страница 245: ...gnition transformer 14 Flue gas exhaust 15 Degassing unit pipe 16 Flue gas probe 17 Upper air vent valve 18 Limit thermostat 19 NTC delivery probe 20 Flame ignition electrode 21 Flame detection electr...

Страница 246: ...Kondenz tum szifon 29 raml skapcsol 30 Visszafoly st g tl szelep 31 Felt lt m gnesszelep 32 Felt lt csap RO Elementele func ionale ale aparatului 1 Manometru 2 Supap de evacuare 3 Servomotor pas cu pa...

Страница 247: ...ione SE arancione SE X1 2 1 3 5 4 rosa blu P N L F 3 15A F 230 V M3 F blu marrone marrone marrone blu PWM marrone blu marrone blu 1 2 4 3 OPE OPE 1 3 X8 M4 blu marrone marrone 6 3 1 2 4 5 blu marrone...

Страница 248: ...dor V Lv Se al control ventilador 3V Servomotor del motor paso a paso de la v lvula de 3 v as PT Diagrama de fia o de multifios A POLARIZA O L N RECOMENDADA Blu Azul Marrom Brown Preto Black Vermelho...

Страница 249: ...h 230 V M20 Puszka elektryczna dla przy czy zewn trznych A B Bus 485 TA Termostat pomieszczenia na styku nie mo e wyst powa napi cie TBOL Nieu ywany TBT Termostat ograniczaj cy niskotemperaturowy SE C...

Страница 250: ...erior 8 Transdutor de press o 9 Man metro 10 Vaso de expans o 11 Sonda de retorno NTC 12 Permutador prim rio 13 Sonda caudal NTC 14 Term stato de limite 15 V lvula de desgasifica o superior 16 Separad...

Страница 251: ...mel nyom s rt k nek figyelembev tel vel kell m retezni Vegye tekintetbe hogy a kaz n akkor m k dik megfelel en ha a h cser l ben a kering v z mennyis ge elegend Ez rt a kaz n el van l tva egy automati...

Страница 252: ...e FLEX AS 5m codd 20087320 e 20091499 20091500 1 2impostati a5 m 0 50 100 150 200 250 300 350 400 0 100 200 300 400 500 600 700 800 900 1000 4 A A A B B B C C C EN graphic 2 setted to 7 metre circula...

Страница 253: ...laci n en interiores PT Instala o interna HU Belt ri telep t s RO Instala ie la interior PL Monta wewn trzny SR Unutra nja instalacija EN Outdoor installation in a partially protected place ES Instala...

Страница 254: ...evacuare condens PT F placa de suporte da caldeira R retorno de aquecimento 3 4 M M descarga de aquecimento 3 4 M G conex o de g s 3 4 M AC gua quente 1 2 M AF gua fria 1 2 M DSV v lvula de seguran a...

Страница 255: ...5 6 TA Szobatermoszt t fesz lts gmentes rintkez bemenet 7 8 TBOL V ztart ly termoszt t 9 10 TBT Alacsony h m rs klet hat rol termoszt t 11 12 SE K ls h m rs klet rz kel je 13 14 OT Nyitott therm 15 16...

Страница 256: ...standard PL H Kolanko 90 G Ko nierz instalowany standardowo SR H koleno od 90 G prirubnica standardno instalirana EN TWIN PIPE 80 mm ES CONDUCTO GEMELO 80 mm PT TUBO DIVIDIDO 80 mm HU OSZTOTT CS 80 mm...

Страница 257: ...D 80 60 mm ou 80 50 mm redu o E curva de 90 50 mm 60 mm ou 80 mm HU A k m ny b lel shez 50 mm vagy 60 mm vagy 80 mm B hossz s g C 90 k ny k k 80 mm D 80 60 mm vagy 80 50 mm sz k t s E 90 k ny k 50 mm...

Страница 258: ...es padr o jumper pos 1 n o inserido T45 temperatura m xima set point aquecimento instala es de piso jumper pos 1 inserido HU A 1 GRAFIKON H SZAB LYOZ S G RB K B 2 GRAFIKON ID J R S KOMPENZ CI S G RBE...

Страница 259: ...SZ S GA 80 80 RO LUNGIME MAX EVI 80 80 PL MAKS D UGO PRZEWOD W 80 80 SR CEVI MAKS DU INE 80 80 EN A flue gas pipe length m B air suction pipe length m ES A Longitud conductos de humos m B longitud con...

Страница 260: ...rpm Data ____ ____ ____ Assinatura __________________________________________ Matr cula da caldeira _________________________________ HU RANGE RATED EN483 A f t si zemm dban a n vleges h kibocs t s __...

Отзывы: