30
EXCLUSIVE
9.2.3 MANUAL
If
MANUAL
is selected, the zone requests will be managed based on the
setpoint set by the user.
9.2.4 HEAT OFF
If
HEAT OFF
is selected, the zone requests will not be fulfilled.
NOTE:
if you want to deactivate the zone in HOT WATER ONLY or in
HEATING AND HOT WATER, you must select the pre-set season (HOT
WATER ONLY or HEATING AND HOT WATER in the BOILER menu) and
set the zone concerned to OFF.
10 SET
With the
SET
function it is possible to configure the
HEATING
,
HOT WATER
and PREHEATING setpoints.
To do this, it is necessary to highlight the desired entry using the
“up”
and
“down”
keys and then pressing
“ok”
to confirm the selection.
Pressing
“back”
takes you back to the initial screen without making any
selection.
10.1
HEATING
SET
HOT WATER
PREHEATING
SET
HEATING
HOT WATER
PREHEATING
Heating
Press the
“up”
and
“down”
keys to change the heating setpoint and
confirm the selection by pressing
“ok”
.
Press
“back”
to return to the
SET
screen without making any selection.
SET
HEATING
78,0
°C
SET
HEATING
When an outdoor temperature sensor is installed, the outlet temperature
is automatically selected by the system, which quickly adjusts the ambient
temperature according to the variations in the outdoor temperature. If you
want to change the temperature, raising it or lowering it with respect to that
automatically calculated by the electronic board, it is possible to change
the HEATING setpoint selecting the desired comfort level within the range
(-5 ÷ +5).
The user is then asked to confirm the setpoint setting: select
CONFIRM
or
CANCEL
using the
“up”
and
“down”
keys, and confirm the selection
pressing
“ok”
.
Once the selection is confirmed, the display returns to the
SET
screen.
If the selection is cancelled or the
“back”
key is pressed you return to the
previous
SET
screen.
SET
THE PARAMETER
WILL BE CHANGED
CONFIRM
CANCEL
CONFIRM OR DELETE
SELECTION
CONFIRM OR DELETE SELECTION
SET
CONFIRM
CANCEL
THE PARAMETER WILL
BE CHANGED
10.2 Hot water
Press the
“up”
and
“down”
keys to change the boiler’s domestic hot water
setpoint. Press
“ok”
to confirm the selection
.
Press
“back”
to return to the
SET
screen without making any selection.
SET
HOT WATER
58,0
°C
SET
HOT WATER
The user is then asked to confirm the setpoint setting: select
CONFIRM
or else
CANCEL
using the
“up”
and
“down”
keys and confirm the
confirmation with
“ok”
.
Once the selection is confirmed, the display returns to the previous
SET
screen.
If the selection is cancelled or the
“back”
key is pressed you return to the
SET
screen.
SET
THE PARAMETER
WILL BE CHANGED
CONFIRM OR DELETE
SELECTION
CONFIRM
CANCEL
CONFIRM OR DELETE SELECTION
SET
CONFIRM
CANCEL
THE PARAMETER WILL
BE CHANGED
10.3 Preheating
This function keeps the water in the domestic hot water exchanger hot,
to reduce standby times when a request is made. When the preheating
function is enabled, the symbol P comes on with a steady light at the top of
the domestic hot water icon. During burner ignition following a preheating
request, the symbol P starts flashing.
It is possible to access the PREHEATING function selecting SET on the
main screen of the REC10.
Setting PREHEATING = 1 the boiler’s domestic
hot water function activates.
To deactivate the preheating function, set the parameter to PREHEATING
= 0, the symbol P switches off.
The function is not active when the boiler is OFF
.
TERMOSTATI SAN
PREHEATING
0
PREHEATING
THE PARAMETER
WILL BE CHANGED
CONFIRM
CANCEL
CONFIRM OR DELETE
SELECTION
CONFIRM OR DELETE SELECTION
CONFIRM
CANCEL
THE PARAMETER WILL
BE CHANGED
11 INFO
The
INFO
function can be used to display a series of data regarding the
system.
ATTENTION
- The displayed data cannot be modified.
Press the
“up”
and
“down”
keys to go through the list of information
available, in this order:
-
SCREED HEATER OPERATING HOURS
-
FLOW PROBE
-
RETURN PROBE
-
DOMESTIC HOT WATER PROBE
-
FLUE GAS PROBE
-
OUTDOOR TEMPERATURE SENSOR
-
EXT T FOR THERMOREG
-
FAN
-
ZONE 1 DELIVERY