It is possible to customise the management of the heating zone by
accessing the ZONES MANAGER menu.
-
Access the technical parameters as explained in the section
-
In sequence select INSTALLATION, ZONES MANAGER and MODIFY
ZONE with the
“up”
and
“down”
keys, confirming the selection.
PARAMETERS
INSTALLATION
THERMOREGULATION
RANGE RATED
TECHNICAL
INSTALLER
CALIBRATION
PARAMETERS
WEATHER COMPENSATION
INSTALLATION
RANGE RATED
CALIBRATION
TECHNICAL
INSTALLER
SENSOR CALIBRATION
INSTALLER
ZONES MANAGER
SYSTEM RESET
SENSOR CALIBRATION
ZONES MANAGER
SYSTEM RESET
INSTALLATION
INSTALLER
ADD ZONE
MODIFY ZONE
DELETE ZONE
INSTALLER
ADD ZONE
MODIFY ZONE
DELETE ZONE
INSTALLER
INSTALLATION
-
S
elect the desired heating zone and then choose from among the options
with the
“up”
and
“down”
keys, confirming the selection:
MAIN
INSTALLER
MAIN
INSTALLER
INSTALLATION
-
TYPE OF ACTUATION
Set the parameter in question to ITRF05/AKM (default value
)
-
TYPE OF HEAT REQUEST
This parameter allows you to specify the type of heat request, it is
possible to choose from among the following options:
THERMOSTAT
(factory setting): the heat request is generated with an
ON/OFF thermostat
REC10 MASTER
: the heat request is generated by the REC10
MASTER; in this case the REC10 assumes the function of MACHINE
INTERFACE
-
TYPE OF ZONE
This parameter allows you to specify the type of zone to be heated, it
is possible to choose from among the following options:
HIGH TEMPERATURE (factory setting):
LOW TEMPERATURE
-
MIN SET HEAT
This parameter allows you to specify the minimum heating setpoint that
is possible (range 20°C - 80.5°C, default 40°C for high temperature
systems - range 20°C - 45°C, default 20°C for low temperature
systems)
-
MAX SET HEAT
This parameter allows you to specify the maximum heating setpoint that
is possible (range 20°C - 80.5°C, default 80.5°C for high temperature
systems - range 20°C - 45°C, default 45°C for low temperature systems)
-
CHANGING NAME
This parameter allows you to attribute a specific name to the heating zone
-
POR
This parameter allows you to enable the central heating programming
timing for the zone concerned if the heat request is carried out using a
room thermostat
Time schedule not enabled = 0
When the room thermostat contact closes the heat request is always
met without any time band limitation
Time schedule enabled = 1
When the room thermostat contact closes the heat request is enabled
according to the programming timing.
Note: in this case make sure that the operating mode of the zone is set
to AUTO in the STATE menu
.
5.2.3 Time band schedule function (room thermostat)
Whenever the heating system is managed by a room thermostat, and
therefore without any time schedule, it is possible to tie the heat requests
coming from the device to programmable time bands by setting the
parameter POR = 1 (see section
“5.2.2 Configuration of the zone”
), in other
cases it is always enabled.
To access this function:
- select MENU on the main page of the REC10 and press
“ok”
18/05/2013
12:17
30
°C
.3
1.3 bar
MENU
INFO
SET
FRI
HOT WATER TEMPERATURE
STATE
PLANT
MON
MENU
STATE
SET
INFO
PLANT
HOT WATER TEMPERATURE
FRI
- using the
“up”
and
“down”
keys select
TIME SCHEDULE
confirming
the selection
SETTINGS
MENU
SELECT OPTION
TIME SCHEDULE
TIME SCHEDULE
SETTINGS
MENU
SELECT OPTION
From this menu it is possible to access the display and adjustment of the
programming timing for the heating functions of the zone. For each day
of the week it is possible to set up to 4 bands, characterised by a starting
time and an end time.
Note:
for more details on the use of the programming timing see the USER
MANUAL of the REC10
.
MON
18/11/2013
12:17
MAIN
SELECT THE ZONE
SCHEDULE
SCHEDULE
MAIN
MON
07:30
11:30
18:00
08:30
13:30
22:30
SELECT
A DAY
START
MAIN
THURSDAY
END
ZONE SCHEDULE
START
END
MAIN
THURSDAY
ZONE SCHEDULE
SELECT A DAY