36
Conventional Fire Panels
J424/J408
TEMPERATURE (°C)
-10
-5
0
5
10
15
20
25
30
35
40
45
50
VOLTAGE (V)
29.0 28.8 28.6 28.2 28.0 27.8 27.4 27.2 27.0 26.8 26.6 26.4 26.2
Table 3
Switching Power Supply Output Voltage chart. To find the Output Voltage using the chart: — select the nea-
rest value to the Probe temperature on the
TEMPERATURE (°C)
row; read the respective value on the
VOLTAGE (V)
row; adjust the Output Voltage of the Switching Power Supply to the indicated value. For example, if the Probe tempe-
rature is 22 °C, the Output Voltage of the Switching Power Supply must be set at 27.4 V.
-10
-5
0
5
10
15
20
25
30
35
40
45
50
26,0
27,0
28,0
29,0
VOL
TA
G
E
(V
)
TEMPERATURE (°C)
a)
27,4
22
Figure 22
Switching Power Supply Output Voltage graph. To find the Output Voltage using the graph: — indicate the
Probe temperature on the
TEMPERATURE (°C)
axis; draw a line from the temperature value point up to the curve
a)
;
draw a line from the intersection point across to the
VOLTAGE (V)
axis; adjust the Output Voltage of the Switching Po-
wer Supply to the resultant value. For example, if the Probe temperature is 22 °C, the Output Voltage of the Switching
Power Supply must be set at 27.4 V.
Содержание J408
Страница 1: ...INSTALLATION MANUAL CONVENTIONAL F I R E PA N E L S 424 408...
Страница 12: ...C N O N C 6 7 8 10 11 26 27 28 29 30 31 9 Figure 2 Maximum configuration of the J424 Control panel...
Страница 17: ...IDENTIFICATION OF PARTS 17 C N O N C 36 35 b...
Страница 29: ...USER S INSTRUCTIONS CONVENTIONAL F I R E PA N E L S 424 408...
Страница 52: ...44 Conventional Fire Panels J424 J408...
Страница 61: ...QUICK GUIDE 53...
Страница 62: ...54 Conventional Fire Panels J424 J408...
Страница 63: ...QUICK GUIDE 55...