Conventional Fire Panels
J424/J408
EVENTS
DETAILS
DESCRIPTION
24R OUT FAULT
None
24R output is shorted
24R OUT RESTORE
None
24R output has been restored
24V OUT FAULT
None
24V output is shorted
24V OUT RESTORE
None
24V output has been restored
ALARM
ZONE
Zone no. + Description The zone concerned is in Alarm status
AUTO UNBYPASSED
Extinguishment Mod. nr. Automatic Extinguishment of Ext. Mod. nr.has been re-enabled
BATT.CHARG.FAULT
Power Supply Stat. nr. Charger of Power Supply Stat. nr. not working properly
BATT.CHARG.REST.
Power Supply Stat. nr. Charger of Power Supply Stat. nr. has been restored
BATTERY DISCONN.
Power Supply Stat. nr. Batteries of Power Supply Stat. nr. disconnected
BATTERY FAULT
None
Panel batteries empty, malfunctioning or disconnected
BATTERY FAULT
Power Supply Stat. nr. Batteries of Power Supply Stat. nr. empty or disconnected
BATTERY FAULT
Power Supply Stat. nr. Batteries of Power Supply Stat. nr. low
BATTERY RECONN.
Power Supply Stat. nr. Batteries of Power Supply Stat. nr. have been restored
BATTERY RESTORE
Power Supply Stat. nr. Batteries of Power Supply Stat. nr have been restored
BATTERY RESTORE
None
Panel batteries have been restored
BATTERY RESTORE
Power Supply Stat. nr. Batteries of Power Supply Stat. nr. empty or disconnected
BUZZER SILENCED
None
The Buzzer has been disabled
BYPASSED ZONE
Zone no. + Description The zone concerned has been disabled
DETECTOR MISSING
Zone no. + Description The detector connected to the zone concerned is not working
DIALLER ACTIVATE
None
Dialler Output has been activated
DISAB.AUTO
Extinguishment Mod. nr. Automatic Extinguishment of Ext. Mod. nr. has been disabled
DL OUT FAULT
None
Dialler connections interrupted or shorted
DL OUT RESTORE
None
Dialler connections has been restored
DL OUTPUT
Enabled/Disabled
The Dialler Output has been disabled/enabled
EM ACTIVATED
Extinguishment Mod. nr. EM Input of Extinguishment Mod. nr. has been activated
EM INPUT FAULT
Extinguishment Mod. nr. EM Input of Extinguishment Mod. nr. shorted or open
EM INPUT RESTORE
Extinguishment Mod. nr. EM Input of Extinguishment Mod. nr. has been restored
EV OUT ACTIVATED
Extinguishment Mod. nr. EV Output of Extinguishment Mod. nr. has been activated
EV OUT FAULT
Extinguishment Mod. nr. EV Output of Extinguishment Mod. nr. shorted or open
EV OUT RESTORE
Extinguishment Mod. nr. EV Output of Extinguish. Mod. nr. has been restored
EVACUATE
None
Evacuation command executed
GND FAULT REST.
None
Control panel ground fault has been restored
GROUND FAULT
None
Control panel leakage to Earth
IE ACTIVATED
Extinguishment Mod. nr. IE Input of Extinguishment Mod. nr. has been activated
IE INPUT FAULT
Extinguishment Mod. nr. IE Input of Extinguishment Mod. nr. shorted or open
IE INPUT RESTORE
Extinguishment Mod. nr. IE Input of Extinguishment Mod. nr. has been restored
INVESTIGATION
None
Investigation executed
MAIN FAULT
None/Pow.SupStat.nr. Mains failure to Control panel/Power Supply Stat. nr.
MAIN RESTORE
None
The Control panel/Power Supply Stat. nr. powered from Mains
MANUAL BYPASSED
Extinguishment Mod. nr. EM Input of Extinguishment Mod. nr. has been disabled
MANUAL UNBYPASS.
Extinguishment Mod. nr. EM Input of Extinguishment Mod. nr has been re-enabled
MODE
Night/Day
Control panel has switched from Night to Day Mode
NAC OUTPUT
Enabled/Disabled
One of the Alarm outputs has been disabled/enabled
NAC1 FAULT
None
Alarm device connections interrupted or shorted
NAC1 RESTORE
None
Alarm device connections interrupted has been restored
NAC2 FAULT
None
Alarm device connections interrupted or shorted
NAC2 RESTORE
None
Alarm device connections interrupted has been restored
OUT 1 RESTORE
Power Supply Stat. nr. O1 Output of Power Supply Stat. nr has been restored
OUT 1 SHORT
Power Supply Stat. nr. O1 Output of Power Supply Stat. nr shorted
OUT 2 RESTORE
Power Supply Stat. nr. O2 Output of Power Supply Stat. nr has been restored
OUT 2 SHORT
Power Supply Stat. nr. O2 Output of Power Supply Stat. nr shorted
OUTS BYPASSED
Extinguishment Mod. nr. Extinguishment Mod. PR, EV and AV outputs disabled
OUTS UNBYPASSED
Extinguishment Mod. nr. Extinguishment Mod. PR, EV and AV outputs re-enabled
PE OUT ACTIVATED
Extinguishment Mod. nr. PR Output of Extinguishment Mod. nr. activated
PE OUT FAULT
Extinguishment Mod. nr. PR Output of Extinguishment Mod. nr. shorted or open
PERIPHERAL FAULT
Peripheral type and nr. The device concerned is missing or faulty
PERIPHERAL REST.
Extinguishment Mod. nr. PR Output of Extinguish. Mod. nr. has been restored
PERIPHERAL REST.
Device type+Number
The device concerned has been restored
Table 2
Event Descriptions (Continues ...):
AV
= Extinguishment Done;
EM
= Manual Extinguishment;
EV
= Electro-
valve;
IE
= Inhibit Extinguishment ;
PR
= Pre-extinguishment;
PS
= Pressure switch.
Содержание J408
Страница 1: ...INSTALLATION MANUAL CONVENTIONAL F I R E PA N E L S 424 408...
Страница 12: ...C N O N C 6 7 8 10 11 26 27 28 29 30 31 9 Figure 2 Maximum configuration of the J424 Control panel...
Страница 17: ...IDENTIFICATION OF PARTS 17 C N O N C 36 35 b...
Страница 29: ...USER S INSTRUCTIONS CONVENTIONAL F I R E PA N E L S 424 408...
Страница 52: ...44 Conventional Fire Panels J424 J408...
Страница 61: ...QUICK GUIDE 53...
Страница 62: ...54 Conventional Fire Panels J424 J408...
Страница 63: ...QUICK GUIDE 55...