USER MANUAL
22
Cancel Command
Press
to cancel the Command, and step back to the
Enter data phase.
Press
to delete wrong digits: the system will emit an
audible feed back signal (2 beeps) to confirm that the
data has been deleted.
Stop Alarm / On Hook
If you are accessing your system via ‘Answering device’
mode, press
to end the call.
If you are accessing your system via ‘Dialler’ mode (after
receiving an Alarm message), press
to interrupt the
ongoing Alarm, and clear the call queue.
Remote Talk / Listen-in
Press
to start the Remote
Listen-in
session, via the
system microphones (if installed).
Press
again to start the
One-way Talk
session, via
the system speakers (if installed).
If required, press
to switch from
One-way Talk
to
Listen-in
mode, and vice versa. The
One-way
Talk
and
Listen-in
modes cannot be active at the
same time.
Press
to start the
Two-way Talk/ Listen-in
session,
via the system microphones and speakers (if installed).
This feature will allow you to listen in on the protected
premises and talk to whoever is present.
Two-way Talk/ Listen-in
sessions can also be acti-
vated by Panic Pendants thus making this feature ex-
tremely useful in Emergency situations involving the eld-
erly or disabled.
If you press
during the
Two-way Talk
session,
the Control panel will switch to
Listen-in
mode.
If the sound quality of the
Two-way Talk
session is poor,
use the
One-way Talk
and
Listen-in
modes (press
).
Zone status / Arm Partitions
This command will allow you to check on the Standby/
Alarm status of the Zone, and the Armed/Disarmed sta-
tus of the Partitions.
The zone or Partition Identifier number
must always
be entered with 3 digits
(if necessary enter a
before the number).
1.
Press
to access the Zone status/Arm Partitions
phase.
2.
Press
to access Zone status, or press
to ac-
cess the Partition status.
Zone status (from step 2)
3a.
Enter the Identifier number of the required zone.
If the zone is associated with a voice message, the
zone status will be indicated by the message.
If the zone is not associated with a voice message,
its status will be signalled by:
1 beep
= zone in standby
2 beeps
= zone in Alarm or Tamper status.
After the status message or audible signal, the sys-
tem will go back to step 1.
Arm/Disarm Partitions (from step 2)
3b.
Enter the Identifier number of the required Partition.
The current status of the Partition status will be indi-
cated by:
1 beep
= Partition Disarmed
2 beeps
= Partition Armed
After the audible signal, the system will go back to step
1.
Turn Reserved Outputs ON/OFF
This command will allow you to control (turn ON/OFF)
the appliances (Sprinkler system, Courtesy lights, etc.)
connected to the
Reserved
Outputs.
The Output Identifier number
must always be en-
tered with 3 digits
(if necessary enter a
before
the number).
1.
Press
to access
Output
control
.
2.
Press
to turn ON, or
to turn OFF the appliance
connected to the Reserved Output.
3.
Enter the Identifier number of the relevant Output.
The appliance will turn ON/OFF immediately, and the
system will go back to step
1.
Structured Arming
This command will allow you to Arm or Disarm the sys-
tem in different modes, in accordance with programming.
1.
Press
to access
Structured Arming
.
2.
Press
to
Arm
all the entered User Code Parti-
tions in
Away
Mode).
3.
Press
to
Disarm
all the entered User Code Parti-
tions.
4.
Press either
,
,
or
to Arm all the entered
User Code Partitions in
A
,
B
,
C
or
D
Mode respec-
tively.
The Partitions will Arm/Disarm immediately, and the sys-
tem will go back to step
1.
Содержание KYO 100