OPERATING  THE  SYSTEM  FROM  A  TELEPHONE

If your system has a 

K3-VOX

 Voice board (accessory

item), and your Installer has duly enabled the User Codes,
you will be able to control your system via any touch-
phone. KYO 300 manages

 

up to 64 Telephone Access

User Codes

 

(KYO 100 manages 16). Each Code can be

programmed to control specific functions and Partitions.

You can access the system over the phone:

after receiving a call from the Control panel;

after calling the Control panel and activating the An-
swering device facility.

Remote Access via ‘Dialler’ mode

If your installer has duly set up your Control panel, the
Dialler will send voice messages to the programmed tel-
ephone numbers when Alarm conditions are detected
(this Control panel manages up to 32 Telephone Num-
bers).
If you receive a Dialler call, you will be able to access
your system during the call by entering your 

Access

Code

 on the telephone keypad.

You can enter your 

Access Code

 while the message is

playing,  or  during  the  pauses  between  message  an-
nouncements.

If the 

Confirm successful calls

 option is Enabled,

you must press the 

  key  (Star)  while  the  voice

message is still running, otherwise the Control panel
will consider the call “Unsuccessful”, and will carry
out the programmed Actions.

Remote Access via ‘Answer’ mode

If your installer has duly set up your Control panels to
answer incoming calls, you will be able to access your
system via the ‘Answering device’ facility.

The Answering function must be Enabled, otherwise,
you will be unable to access your system via remote
telephone. DO NOT use a telephone with a redial
button to Arm or Disarm your system, as this may
put your system security at risk.

If you are accessing your system via the ‘Answering de-
vice’ facility, two conditions are possible:

Teleservice Enabled

Teleservice Disabled

Teleservice Enabled

If the ‘Answer’ and ‘Teleservice’ facility are both Enabled,
your system will answer your call  after the programmed
number of rings. It will emit a high-pitch audible signal
(beep), wait approximately 4 seconds then will play the
Answer message. At this point, you can enter your PIN
and send the required commands over the phone.

Teleservice Disabled

If the ‘Teleservice’ facility is Disabled, your system will
answer your call  after the programmed number of rings.
It will emit a low-pitch audible signal then will play the
Answer message. At this point, you can enter your PIN
and send the required commands over the phone.

Entering the PIN code

You can enter your PIN while the message is playing, or
during the pauses between message announcements,
regardless of the Telephone Access mode (Dialler or An-
swer Mode).
Enter your Access Code then press 

.

If your system recognizes your code, it will emit an audi-
ble feed back signal (short high-pitched beep), and will
accept commands.
If your system DOES NOT recognize your code, it will
emit an audible error signal (buzz).
The system will end the call automatically, if no valid
code is entered within 30 seconds (at default). This in-
terval can be customized from 1 to 254 seconds.
If necessary, press 

 to delete wrong digits and restart.

Entering Commands

Once your PIN has been recognized, you can enter the
Command Codes. If you enter a wrong Code, the sys-
tem will emit an audible error signal (buzz)
If you enter a valid Code, the system will emit an audible
confirmation signal (beep).

The system will end the call automatically, if no Key
is pressed within 2 minutes.

Содержание KYO 100

Страница 1: ......

Страница 2: ...ce with the local laws and bylaws in force Hereby Bentel Security declares that the KYO100 and KYO300 Control panels comply with the essential requirements and other relevant provisions of Directive 1...

Страница 3: ...ing the system from an ALISON 32LP LED Keypad 15 Reset Alarms 16 Enable Disable auto arm 16 Enable Disable Teleservice 16 Overtime Request 16 Teleservice Request 16 Enable Disable Buzzer 16 Test Siren...

Страница 4: ...Alison 32LP Keypads 1 Function LEDs 2 Display 3 Microphone Alison DV only 4 Keys 5 Information chart 6 Flip 7 Instant Action Keys MIA D only OPERATING YOUR SYSTEM FROM A KEYPAD Contrast Adjustment To...

Страница 5: ...32LP LEDs Refer to Table 2 for the description of the four LEDs on the Keypad Display During standby status the first line will show the Time and Date as follows If the Control panel has stored a zon...

Страница 6: ...af AKFG aDgGNCCQSOhi QNGDGg oGlLIODLMGSHIEMG HVSEDGiLSEIGLDGJUFMLJnEJj GoGGlLIODLMGSHIEMG HVSEDGKHFGXMEHDEJGNeOGHOGMEHFOGLIEGaSEIGCHIEMGEfEIOGUIGVEVLDQ GoG_QFOEVG HVSED GoG_QFOEVG HVSEDGKHFGXMEHDEJGNe...

Страница 7: ...urations A B C and D These con figurations determine the Partitions which will Arm and those which will Disarm when an A B C or D Mode command is entered at a Keypad the final configuration depends on...

Страница 8: ...KEGlLIODLMGSHIEMGNHOOEDQGLDGHOGMEHFOGLIEGCLsEDG_OHOULIGUFGILOGReIXOULIUInGSDLSEDMQ KEGlLIODLMGSHIEMGNHOOEDQGLDGHOGMEHFOGLIEGCLsEDG_OHOULIGNHOOEDQGUFGMLs KEGdHUIFGSLsEDGOLGOKEGlLIODLMGSHIEMGLDGOLGHOGME...

Страница 9: ...recording Memo Event logger Clear call queue Enable Disable Timers Enable Disable Key Your Installer has programmed your Control panel with your requirements in mind Therefore some of the options may...

Страница 10: ...ys UNBYPASS turn ON or BYPASS Turn OFF the zone as required 4 Use C or D to scroll the zones and continue or press the e key twice to step back to the User menu Attempts to Arm turn ON the Partitions...

Страница 11: ...e 5 6 The Teleservice request will stop any ongoing Telephone calls Teleservice requests from the User have priority over other call types and will send the Teleservice call or calls to the Installer...

Страница 12: ...ge for sev eral seconds before stepping back to the User menu 2 To Abort the Command Press the e key to step back to the User menu Overtime request If the Auto arm option is enabled and the system is...

Страница 13: ...message 0 To clear this Trouble condition select the Reset PC Prog option from the User menu and press the E key the display will show the following message for several seconds and the G LED will tur...

Страница 14: ...lled by the G LED ON on the Keypad theDiscovered PIN messageinViewTroublemode the Event details in the Logger TYPE Discovered PIN IDENT the Keypad used TIME Time and Date of the Event The Trouble stat...

Страница 15: ...et the Continuous Recording facility and step back to the User menu Enable Disable Timers This Control panel manages up to 64 Timers 32 Timers for KYO 100 for control of the ON OFF Times of electri ca...

Страница 16: ...leservice facility refer to page 11 proceed as follows 1 Access the Programming phase 2 Press LED 2 on the Keypad will turn ON OFF to indicate re spectively the Enabled Disabled status of the Teleserv...

Страница 17: ...eader The Partitions the Reader can control Reader Parti tions A Mode Arming AMBER Fig 3 a SAT Digital key b ECLIPSE key reader c PROXI CARD d PROXI reader e Alison 32LP Keypad B Mode Arming GREEN Dig...

Страница 18: ...the SAT Key was inserted To Reset push the SAT Key into the ECLIPSE Reader until the 3 LEDs start to blink slowly the previous setting will be restored when you remove the Key b Red LED ON The System...

Страница 19: ...the PROXI Reader The LEDs will light in turn at 2 second intervals Fig 4 Disarm Arm Stop Alarms FROM ECLIPSE Readers 2b Remove the Key Card when the Amber LED turns ON At this point the Red LED will a...

Страница 20: ...Key in use Stay Mode Press the button until the LED turns ON see Fig 5 to Arm all the Partitions of the Wireless Key in use in Stay Mode Disarm Press the button until the LED turns ON see Fig 5 to Dis...

Страница 21: ...Arm or Disarm your system as this may put your system security at risk If you are accessing your system via the Answering de vice facility two conditions are possible Teleservice Enabled Teleservice D...

Страница 22: ...ts if necessary enter a before the number 1 Press to access the Zone status Arm Partitions phase 2 Press to access Zone status or press to ac cess the Partition status Zone status from step 2 3a Enter...

Страница 23: ...s This command will allow you to clear Partition and or Control panel Alarms restore the system to standby depending on the Access level of the Code used via Tel ephone Enable Disable Current User Cod...

Страница 24: ...astica 64013 Corropoli TE ITALY Tel 39 0861 839060 Fax 39 0861 839065 e mail info bentelsecurity com http www bentelsecurity com ISTUSBLEKYO300 2 0 270904 P7 0 TBUVWO OHOIW B VTO AcE GF IQEKpD LDFG Ac...

Отзывы: