P
ag
e
40
Soft Key Menu: Tools
(when Spectrum is selected)
The tools settings allow you to select TTL Out, RPM ON, Time in DU, Calibration,
Hot Keys setup, Mark Cursor, Undo Mark Cursor, and Clear All Marks. Press the
[
Tools
] function key to select. The tool works in together with many of the
display functions. For example, you can mark the cursor on the display, which
will be shown in the next section.
TTL Out
: TTL out allows the user to move the cursor to a frequency and when
connecting a stroboscope or strobe light to
the TTL out (proper TTL cable is required),
the strobe light will flash at that frequency.
This is a simple yet effective way to identify
problematic frequencies in the field. In this
example, the TTL out frequency is set at 60
Hz.
RPM ON
: This will display the RPM on the display