6 – Parameter List
59
Table 19: FUNCTION Group Parameter List
Parameter
Description
Units / Range
Default
Adjust
During Run?
Modbus Reg-
ister
FUNCTION-22
Overcurrent Level
1 – 300%
120
Yes
40077
FUNCTION-23
Overcurrent Trip Time
0.0 – 600.0 sec
0.1
Yes
40078
FUNCTION-24
Undercurrent Enable
0: Disabled
1: Enabled
Disabled
Yes
40134
FUNCTION-25
Undercurrent Level
1 – 99%
1
Yes
40135
FUNCTION-26
Undercurrent Trip Time
0.0 – 600.0 sec
0.1
Yes
40136
FUNCTION-27
Output Phase Loss Enable
0: Disabled
1: Enabled
Disabled
Yes
40079
FUNCTION-28
Output Phase Loss Level
50 – 150%
90
Yes
40080
FUNCTION-29
Output Phase Loss Trip Time
0.1 – 600.0 sec
0.1
Yes
40081
FUNCTION-30
Backspin Lockout Enable
0: Disabled
1: Enabled
Disabled
Yes
44490
FUNCTION-31
Backspin Lockout Time
10 – 3600 sec
10
Yes
44491
FUNCTION-32
Local Control Source
0: Digital Input
1: HMI
2: Modbus TCP
3: DeviceNet
HMI
No
44448
FUNCTION-33
Remote Control Source
Digital Input
No
44449
FUNCTION-34
Local Speed Reference Source
0: HMI
1: Inverter Analog Inpt 1
2: Inverter Analog Inpt 2
3: Inverter Analog Inpt 3
4: Inverter Analog Inpt 4
5: Inverter Analog Inpt 5
6: Inverter Analog Inpt 6
7: Inverter Analog Inpt 7
8: Inverter Analog Inpt 8
9: CCI Analog Input 1
10: CCI Analog Input 2
11: CCI Analog Input 3
12: CCI Analog Input 4
13: CCI Analog Input 5
14: CCI Analog Input 6
15: CCI Analog Input 7
16: CCI Analog Input 8
17: Modbus TCP
18: DeviceNet
HMI
No
44452
FUNCTION-35
Remote Speed Reference Source
Analog
Input 3
No
44453
FUNCTION-36
Controller IP Address 1
0 – 255
172
No
44454
FUNCTION-37
Controller IP Address 2
0 – 255
29
No
44455
FUNCTION-38
Controller IP Address 3
0 – 255
87
No
44456
FUNCTION-39
Controller IP Address 4
0 – 255
15
No
44457
Содержание M2L 3000
Страница 2: ...M2L 3000 Series VFD 2...
Страница 6: ...M2L 3000 Series VFD 6...
Страница 10: ...M2L 3000 Series VFD 10...
Страница 14: ...M2L 3000 Series VFD 14 Part Number Definitions UL Applicable Base Part Numbers...
Страница 15: ...1 Introduction 15 NOTE Only the 260A and 300A models are presently available as UL listed models...
Страница 16: ...M2L 3000 Series VFD 16...
Страница 27: ...3 Installation 27 Wiring Schematics Figure 1 MV Drive System Layout...
Страница 28: ...M2L 3000 Series VFD 28 Figure 2 Converter Power and Control Circuit Portions...
Страница 29: ...3 Installation 29 Figure 3 Inverter Power and Control Circuit Portions...
Страница 40: ...M2L 3000 Series VFD 40...
Страница 72: ...M2L 3000 Series VFD 72...
Страница 124: ...M2L 3000 Series VFD 124...
Страница 126: ...M2L 3000 Series VFD 126...
Страница 127: ...References 127 References Placeholder for text with left side label...
Страница 128: ...M2L 3000 Series VFD 128...
Страница 132: ...M2L 3000 Series VFD 132...
Страница 139: ...Revision History 139 Revision History Revision Date ECO Description 00 December 15 2017 E5306 Initial Release...