8 – Fault Conditions
113
Table 22: Fault Conditions
Fault
Code
Fault Displayed
Reaction
Type
Description
Course of Action
533
Cell C1 Configuration
fault
C
Occurs when any cell reports that it
has not received its configuration
parameter settings from the Computer
Card.
If this always occurs with the same cell, the
cell could be malfunctioning. Replace the
cell.
If this occurs while the drive is running, it
may be an indication that a cell reset during
operation. Contact Benshaw.
534
Cell C2 Configuration
fault
535
Cell C3 Configuration
fault
536
Cell C4 Configuration
fault
537
Cell C5 Configuration
fault
538
Cell C6 Configuration
fault
539
Cell C7 Configuration
fault
540
Cell C8 Configuration
fault
541
Cell C9 Configuration
fault
542
Cell C10 Configuration
fault
543
Cell C11 Configuration
fault
544
Cell C12 Configuration
fault
545
Cell C13 Configuration
fault
546
Cell C14 Configuration
fault
547
Cell C15 Configuration
fault
548
Cell C16 Configuration
fault
551
FOB C Backplane
Communication fault
C
Occurs when the Power Fiber Optic
Board on phase C receives a bad
message from the Computer Card over
the backplane in the card cage.
Replace the Fiber Optic Board. If the
problem persists, contact Benshaw.
552
FOB C Fiber
Communication fault
C
Occurs when the Power Fiber Optic
Board on phase C receives a bad
message from a cell over a plastic
optical fiber optic (POF) connection.
Replace the Fiber Optic Board. If the
problem persists, contact Benshaw.
Содержание M2L 3000
Страница 2: ...M2L 3000 Series VFD 2...
Страница 6: ...M2L 3000 Series VFD 6...
Страница 10: ...M2L 3000 Series VFD 10...
Страница 14: ...M2L 3000 Series VFD 14 Part Number Definitions UL Applicable Base Part Numbers...
Страница 15: ...1 Introduction 15 NOTE Only the 260A and 300A models are presently available as UL listed models...
Страница 16: ...M2L 3000 Series VFD 16...
Страница 27: ...3 Installation 27 Wiring Schematics Figure 1 MV Drive System Layout...
Страница 28: ...M2L 3000 Series VFD 28 Figure 2 Converter Power and Control Circuit Portions...
Страница 29: ...3 Installation 29 Figure 3 Inverter Power and Control Circuit Portions...
Страница 40: ...M2L 3000 Series VFD 40...
Страница 72: ...M2L 3000 Series VFD 72...
Страница 124: ...M2L 3000 Series VFD 124...
Страница 126: ...M2L 3000 Series VFD 126...
Страница 127: ...References 127 References Placeholder for text with left side label...
Страница 128: ...M2L 3000 Series VFD 128...
Страница 132: ...M2L 3000 Series VFD 132...
Страница 139: ...Revision History 139 Revision History Revision Date ECO Description 00 December 15 2017 E5306 Initial Release...