M2L 3000 Series VFD
46
Operating the Drive
With default parameter settings, the Drive can be fully operated from buttons on the HMI. If a plant
PLC or some other control source is active, the
Start
and
Stop
buttons will not be available, and
the speed setpoint will be shown as a meter.
NOTE
: Basic parameter settings for your application were set during drive
commissioning. If changes from those settings are required, select
Parameter Settings
from the navigation menu to select and change any parameters required.
1. Navigate to the
Main
view.
2. Select
Setpoint
to set the desired speed of the motor in Hz.
NOTE:
The allowable range of 0-300Hz presented by the HMI will not always match
parameter settings. If a value is entered outside of the range defined by the
Minimum
Frequency
and
Maximum Frequency
Drive parameters, the setpoint will change to the
nearest acceptable value.
NOTE:
A negative setpoint is not used to run the Drive in reverse. The
Run Reverse
button takes the inverse of the speed setpoint to run at a negative frequency.
3. To start the motor, select
Start
. The Drive will accelerate according to the
Start Mode
and
other parameter settings.
NOTE
: If reverse capabilities are enabled, select either
Run Forward
or
Run Reverse
to
start the motor.
4. To stop the motor, select Stop. The Drive will stop the motor according to parameter settings.
NOTE:
The speed setpoint can be adjusted at any time while the drive is running.
Содержание M2L 3000
Страница 2: ...M2L 3000 Series VFD 2...
Страница 6: ...M2L 3000 Series VFD 6...
Страница 10: ...M2L 3000 Series VFD 10...
Страница 14: ...M2L 3000 Series VFD 14 Part Number Definitions UL Applicable Base Part Numbers...
Страница 15: ...1 Introduction 15 NOTE Only the 260A and 300A models are presently available as UL listed models...
Страница 16: ...M2L 3000 Series VFD 16...
Страница 27: ...3 Installation 27 Wiring Schematics Figure 1 MV Drive System Layout...
Страница 28: ...M2L 3000 Series VFD 28 Figure 2 Converter Power and Control Circuit Portions...
Страница 29: ...3 Installation 29 Figure 3 Inverter Power and Control Circuit Portions...
Страница 40: ...M2L 3000 Series VFD 40...
Страница 72: ...M2L 3000 Series VFD 72...
Страница 124: ...M2L 3000 Series VFD 124...
Страница 126: ...M2L 3000 Series VFD 126...
Страница 127: ...References 127 References Placeholder for text with left side label...
Страница 128: ...M2L 3000 Series VFD 128...
Страница 132: ...M2L 3000 Series VFD 132...
Страница 139: ...Revision History 139 Revision History Revision Date ECO Description 00 December 15 2017 E5306 Initial Release...