InstAllAtIon InstRUctIons - GAs
3. The wire which is coloured brown must
be connected to the terminal marked
A(Active/Live), or coloured Red.
The plug and socket must be accessible
after installation. Should the mains lead
of the appliance ever require replacing,
this must be carried out by a qualified
electrician who will replace it with a lead
of the same size and temperature rating.
Important: - ensure that you route all
mains and electrical cables and flexible
tubing well clear of any adjacent heat
source.
Under no circumstances should the mains
electric cable be allowed to come into
contact with the vertical oven flue tubes
on the rear of the appliance.
checking the gas supply
Check the manometer zero point is
correct. Connect the manometer to the
cooker pressure test point. Turn on the
gas supply and the electricity then try to
ignite the gas.
Note: It will take additional time to light
the gas for the first time as air needs to
be purged from the pipes.
Check the operating pressure for the
particular gas types.
NG 1.00 kPa, LPG 2.75 kPa
For lPG cookers
Adjust the regulator if necessary (this
may be remote from the cooker).
For nG cookers
Regulators are supplied pre-adjusted
and configured by the component maker
for use with Natural Gas. The appliance
installer should not be required to make
an adjustment to obtain the correct outlet
pressure setting. Regulator outlet pres-
sure should be checked when
a) All burners are operating simultane-
ously at the full on setting.
b) When the smallest burner of the appli-
ance is operating at the low setting.
Under these conditions the outlet pres-
sure should be between 0.8 kPa and 1.2
kPa.
coMMIssIonInG
Burner aeration
All burners have fixed aeration and no
adjustment is possible.
Check the ignition of all burners both
separately and in combination. see
IGnI-
tIon PRoceDURe
page as described
earlier in this booklet.
Check the operation of electrical compo-
nents, viz;
clock programmer/ Minute minder
Check functions as described earlier in
this booklet.
oven light
Push the light button for ON, push button
again for OFF.
oven convection fan
Open the oven door, push the fan button,
look into the oven and check fan is ON,
push button again for OFF.
cooling fan
Open the grill door. Ignite the grill burner
and check that the cooling fan switches
on within approx. 2 minutes. As soon as
the cooling fan switches on, turn off the
grill control knob and check that the fan
switches off within approx. 2 minutes.
lid safety system
Ignite all hotplate burners including wok.
Attempt to close the lid and make sure
all flames are extinguished by the safety
system.
Содержание 83180302
Страница 1: ...Belling Freestanding Fanned Gas AU Users Guide Installation Handbook Part No 083180302 Date 26 07 2012...
Страница 40: ...Please keep this handbook for future reference or for anyone else who may use the appliance...
Страница 41: ...Please keep this handbook for future reference or for anyone else who may use the appliance...
Страница 42: ...Please keep this handbook for future reference or for anyone else who may use the appliance...
Страница 43: ...Please keep this handbook for future reference or for anyone else who may use the appliance...