InstAllAtIon InstRUctIons - GAs
connect to tHe GAs sUPPlY
Means of isolation shall be provided at
the shut off point by either an approved
quick connect device or a Type 1 manual
shut off valve. The outlet of the quick
connect device shall be at, or below, the
horizontal position.
Connection to the gas supply should be
made using the Aquaknect AS/NZS 1869
class B hose assembly with an internal
diameter of not less than 10mm and
regulator (regulator for use with natural
gas).
For operation on nG
The appliance regulator provided must be
oriented so that the pressure nipple (on
the outlet) is accessible. The governor
must be fitted to the supply line.
For operation on lPG (propane).
The pressure test point fitting provided
must be fitted to the supply line.
NOTE: The temperature rise of the areas
at the rear of the cooker that are likely to
come into contact with the flexible hose
do not exceed 70˙C.
The inlet to the cooker is ½” BSP internal
situated at the rear right corner. Fit the
bayonet connection. This should be
located so as to ensure that the flexible
connector hose does not kink.
Under no circumstances should the
flexible connector be allowed to
come into contact with the vertical
oven flue tubes on the rear of the
appliance.
Use a 900mm - 1200mm length of flexible
connector.
Ensure that all pipework is of the correct
rating for both size and temperature.
Natural Gas- Installations must conform
to local codes or, in the absence of lo-
cal codes with AS:5601 as well as the
requirements of any local council, gas,
electricity authority or other statutory
regulation.
After installation, make sure all con-
nections are gas sound.
connect to tHe electRIcItY sUP-
PlY - GAs
(mains ignition models only)
Warning: This appliance must be earthed.
The flexible mains lead is supplied con
-
nected to a mains plug which complies
with AS/NZS 3112.
Replace only with a plug of the same type
and rating.
1. The wire which is coloured green and
yellow must be connected to the terminal
marked E (Earth) or coloured Green.
2. The wire which is coloured blue must
be connected to the terminal marked N
(Neutral), or coloured Black.
WIRING SIDE OF THE PLUG
Содержание 83180302
Страница 1: ...Belling Freestanding Fanned Gas AU Users Guide Installation Handbook Part No 083180302 Date 26 07 2012...
Страница 40: ...Please keep this handbook for future reference or for anyone else who may use the appliance...
Страница 41: ...Please keep this handbook for future reference or for anyone else who may use the appliance...
Страница 42: ...Please keep this handbook for future reference or for anyone else who may use the appliance...
Страница 43: ...Please keep this handbook for future reference or for anyone else who may use the appliance...